Minimal framed large panel sliding glass wall (23 pages)
Summary of Contents for NanaWall HSW75
Page 1
This Owner’s Manual contains instructions on the installation, operation, maintenance and warranty of the NanaWall HSW75 Single Track Sliding Frameless System. This manual is to be used by the installer for installation and is to be kept by the Owner for reference. Replacement parts can be ordered directly through NanaWall Systems.
Page 2
The NanaWall glass thickness for the panels is based on the Glass Association of North America (GANA) recommended minimum glass thickness for fully The installation of the HSW75 System requires a working tempered Interior butt glazed fixed glass panels. knowledge and experience in the use of tools, equipment...
Page 3
NANAWALL HSW75 OWNER’S MANUAL DIAGRAM 1: EXAMPLE OF A 5 PANEL UNIT I NS I D E OU TS I D E Panel #1: sliding panel Panel #2: sliding panel Panel #3: sliding panel Panel #4: sliding panel Panel #5: double action end panel (non-sliding) with pivot box or...
Page 4
• Specified floor sockets, pivot points, pivot boxes and Please refer to the layout drawing of your particular floor closers HSW75 project for the correct location of the support structure (by others) for the support of the head track • Crank handle for single/double action sliding panels, at the opening, stacking route and stacking bay.
UNIT INSTALLATION and other similar precise measuring equipment The Installation of the unit is described should be used. YOU NEED TO ADJUST THE in the HSW75 Installation Manual: FLOOR AT THE OPENING TO MAKE IT ABSOLUTELY LEVEL. Sheet 1. Required Tools 6.
Page 6
The key to having a properly installed and The spacing of anchorage devices in the stacking bay operating HSW75 system is to install a perfectly should be every 4"and in the stacking route every about level upper track at the correct height from 10"...
Page 7
NANAWALL HSW75 OWNER’S MANUAL Attention should also be made to the minimum edge Otherwise, the running carriages may wear out distance that must be maintained for different substrates. prematurely, which will then not be covered by Generally, for wood frame, minimum embedment is 2 1/2"...
Page 8
NANAWALL HSW75 OWNER’S MANUAL Then remove the roller access head track section (RHT). THE HEAD TRACK VIA THE CONVERSION See Step 0 on Sheet 6 of the Installation Manual. Hang BOX AND THE QUICK RELEASE LOCK ON THE sliding panels by inserting the carriers on each panel into PIVOT SIDE HAS TO BE SECURED TO THE the opening in the head track in the proper sequence.
Page 9
NANAWALL HSW75 OWNER’S MANUAL To adjust the height of the panels, remove the end cap the locking bolts. Slowly and carefully engage the locking on the side of the carrier of the top rail and loosen the set points until it touches the tape. The tip of the locking...
Page 10
NANAWALL HSW75 OWNER’S MANUAL (43 mm) plus the additional 3/16" (4 mm) for the gap to Manual. Mark this point and if concrete, use a diamond the wall. See Sheet 11 of the Installation Manual. This core drill bit with 1 1/4" diameter. Install the bottom pivot means we have a total of 1 7/8"...
Page 11
NANAWALL HSW75 OWNER’S MANUAL of the axle of the floor closer with the center of the top of the top track and fix it slightly with the 2 set screws. axle. See Sheet 12 of the Installation Manual. Use a transit/laser or other similar precise measuring...
Page 12
NANAWALL HSW75 OWNER’S MANUAL double action sliding panel into a single/double action operations that can permanently damage and destroy door is by engaging the Quick Release Lock into the Pivot it. A unit can be damaged by cement splatter, tar, paint, Box.
Page 13
Do not force the system if not operating properly. If you appropriate switch into the stacking bay. encounter any difficulties in operating the unit, please have it inspected by a NanaWall certified installer as 6. In most cases, panels can be pushed in place with soon as possible.
Page 14
NANAWALL HSW75 OWNER’S MANUAL 10. Convert the single/double action sliding panels from CONVERSION OF A SINGLE/DOUBLE ACTION sliding panels to swing panels as per instructions SLIDING PANEL FROM A SWING PANEL TO A below. SLIDING PANEL Close the swing panel.
2. From time to time, due to building movement or settlement, a unit may need to be adjusted All hardware, hinges and handles should by a qualified technician or a NanaWall certified be periodically cleaned with a soft cloth installer to compensate for any building change.
Page 16
Ensure that any lock and profile cylinder can be moved easily Please get in touch with NanaWall before you replace a glass pane in order to get the right material and For single/double action sliding panels, instructions to glaze the panel!
Page 17
NANAWALL HSW75 OWNER’S MANUAL SOME SPECIFIC SUGGESTED MAINTENANCE 5. As with any painted surface exposed to corrosive FOR COASTAL SALT WATER AND OTHER environments, every 6 months apply a wax to the EXTREME ENVIRONMENTS: outside of the painted panel and painted track. If the...
Page 18
May 1, 2022, to be installed in the United States (excluding territories) or Canada. NanaWall shall have no obligation to respond under this Warranty until receipt of proper notice of a claim and an opportunity to respond. Upon notice and confirmation by NanaWall of a condition covered under this Warranty, NanaWall will respond in good faith and in a timely manner as follows: TEN YEAR COVERAGE.
Screens. For a screen part (excluding the screen mesh) with a material or workmanship issue that substantially impairs the function of the screen, NanaWall will, at its option, (1) ship a replacement screen or (2) upon return by owner, repair the screen without charge.
Page 20
This Warranty may only be modified by a writing signed by an officer of NanaWall. Any action taken by NanaWall does not create a new warranty or extend the duration of the original product warranty. A failure by NanaWall to enforce a warranty provision shall not constitute a waiver barring subsequent enforcement.
Page 21
• Products or components not supplied by NanaWall; Products that have not been paid for in full; Products ordered in larger sizes or special configurations beyond NanaWall’s published specifications. Product with glass that is heavier than NanaWall specifications;...
Page 22
NanaWall Warranty Registration Must be filled out and returned to Nana Wall Systems, Inc., 100 Meadowcreek Drive, Corte Madera, CA 94925 within 30 days from date of purchase of the NanaWall in order for the limited warranty to become effective. ________________________...
Need help?
Do you have a question about the HSW75 and is the answer not in the manual?
Questions and answers