Summary of Contents for Rangevision PRO

  • Page 1     RANGEVISION   Setup​ ​ a nd​ ​ c alibration   PRO       ...
  • Page 2: Table Of Contents

    Contents  Introduction 3  Technical​   ​ s pecifications 4  System​   ​ r equirements 5    Preparing​   ​ f or​   ​ ork  Package​   ​ c ontents 5  Installing​   ​ s oftware​   ​ a nd​   ​ d rivers 7 ...
  • Page 3: Introduction

    Introduction  Thank you for choosing RangeVision product.  Please read this manual before using RangeVision 3D scanner. Here are described the  procedures for preparing the scanner, installing the required drivers, calibration  procedure, scanning procedure, and tips for acquiring high-quality three-dimensional  object model.  Information may be amended from time to time. These changes will be inserted into the ...
  • Page 4: Technical S Pecifications

    Specifications for PRO:    FOV  [L]  [M]  [S]  Scanning area (WxHxD),  550х340х360  320х210х200  140х90х80  mm  3D-resolution, mm  0,18  0,10  0,04  Scanning distance, mm  900  520  350    Specifications for PRO Base:    FOV  [L]  [M]  [S]  Scanning area (WxHxD),  520х390х360  280х210х200  115х85х80  mm  3D-resolution, mm  0,25  0,13  0,05  Scanning distance, mm  900 ...
  • Page 5: System R Equirements

      System requirements:  operating system - Windows 7/8/10 64bit,  ● ● processor - Intel Core i3/i5 1.8 GHz and better,  ● graphics card with HDMI output,  RAM - not less than 8 GB.  ●   Preparing for work  Package contents  RangeVision 3D scanner is supplied in a plastic box with lodgement, optionally can  be supplied in a protected road hard case.  The scanner is equipped with at least one scanning area. Scanning area is a set of  interchangeable optics, calibration plate and stand for the calibration plate.      5 ...
  • Page 6   №  Name  qty.  1  Scanning module:    Installation construction with projector  1  Cable kit for connection to a PC (2 USB + HDMI)  1  2  Machine vision camera  2  3  Tripod  1  4  Calibration plate  1-4*  5  Kit of interchangeable optics  1-5*  6  Stand for the calibration plate  1-2*  7  USB disk with the software  1  8  The electronic key  1  9  Matting spray  1  10  Markers for scanning  1  11  Power Cord 5 m  1 ...
  • Page 7: A Nd D Rivers

      ​ s canner)​   ​ a nd​   ​ r un​   ​ t he​   ​ i nstaller​ ​   RangeVision​ ​ S сanCenter​   ​ N G​   ​ s etup​ .         Following​...
  • Page 8: F Or T He W Ork W Ith T He S Canner

    Setting up your computer for the work with the  scanner  For​ ​ t he​ ​ c orrect​ ​ o peration​ ​ o f​ ​ R angeVision​ ​ 3 D​ ​ s canner​ ​ y ou​ ​ w ill​ ​ n eed​ ​ t o​   ​ s etup​  ...
  • Page 9: Configuring C Omputer P Arameters

    Configuring computer parameters  To avoid a recurrence of the problems during the scanner operation, you must turn  off the screensaver and sleep mode.  By clicking right mouse button on the desktop, select Personalize → Screensaver and  turn off the screensaver, disable turning off the display and putting the computer in  sleep mode.            9 ...
  • Page 10: Scanner A Ssembly

    Scanner Assembly      Carefully get the scanning module and all accessories out of the plastic case.  Set the tripod on the flat and stable surface.  Fit the scanning module on the tripod.  Attach the cameras to the scanner, if they are not attached yet. Cameras  must rotate around their axis facing each other, not in opposite directions.  Install the camera lens kit (if not yet installed). Choice of lenses is described in  the section dedicated to Scanner Setup.  Connect USB cable to the scanner and to the computer. Connection should  be made after the driver installation.  Connect the power cord (220V) to the projector and turn on the main power.  The switch is located on the bottom of the scanner next to USB, HDMI and  power sockets.  Connect HDMI cable to the scanner and to the computer.  Turn on the projector by pressing the button on top of the scanning module.  Insert the electronic key into a free USB port.  Connect the rotary table (if equipped) to your computer using the USB  cable. The TL model also requires to connect the power cord (3m cable).      10 ...
  • Page 11: Scanner S Etup

    Scanner setup  ScanCenter NG launch  Run​   ​ R angeVision​   ​ S canCenter​   ​ N G​   If​   ​ t he​   ​ s canner​   ​ i s​   ​ n ot​   ​ c onnected​   ​ o r​  ...
  • Page 12     ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ For​ n ormal​ o peration,​ s ome​ s canner​ m odels​ r equires​ w arming​ u p.​ I f​ t he​ ​ c ameras​ a ren't ​ ​...
  • Page 13: Select S Canning Z One

    Select scanning zone  ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ After​ p reparatory​ a ctions​ o n​ s etting​ u p​ t he​ c omputer,​ y ou​ s hould​ c arry​ t he​ ​ s canner ​ ​ ​...
  • Page 14: Lenses I Nstalling

    Lenses installing  Set the cameras lenses, corresponding to the selected scanning zone. The scanning  zone number is specified on the lens. Securely tighten the objectives. Try not to touch or  let any dust on the objectives and cameras lenses.    Blue Light  For scanning with unfavorable external lighting conditions it is recommended to use the  “blue light” technology (may not be included in the package. In order to do this Blue Light  filters must be installed on the cameras lenses and the corresponding mode must be  activated in ScanCenter NG options. Do not activate this mode with no filters installed  and vice-versa. ...
  • Page 15   While​   ​ i nstalling​   ​ B lue​   ​ L ight​   ​ f ilters,​   ​ b e​   ​ g entle​   ​ a nd​   ​ d o​   ​ n ot​   ​ p ut​...
  • Page 16: C Ameras A Nd L Enses

        Initial setup of cameras and lenses  When you first set up the scanner, image from the cameras may be too bright or too  dark due to different external lighting conditions. Adjust camera lenses, so that the  brightness is acceptable: without the red overexposed areas and not too dark.  Lens adjustment is carried out by rotating the ring on the objective. Loosen (do not  unscrew!) the retention screw and rotate the ring.        16 ...
  • Page 17: The C Alibration P Late

    Lens​   ​ a djustment​   ​ i s​   ​ c arried​   ​ o ut​   ​ b y​   ​ t he​   ​ f ollowing​ ​ lements:    The​   ​ i ris​   ​ t uning​  ...
  • Page 18: O F T He P Rojector F Ocus

    Adjustment of the projector focus  During the scanner operation the projector projects structured light to the object - coded  lines and stripes. To ensure that the lines are sharp, the projector must be focused on  the working distance of the scanner.  By switching the mode "Lines and Stripes", adjust the focus of the projector, so that the  lines on the calibration plate were as sharp as possible. Using the zoom ring set the  minimum possible area of projector light. ...
  • Page 19: T He C Ameras T Ogether

    Bringing the cameras together  For the work of the scanner it is necessary to point both cameras to the same position  on the specified working distance. Install the calibration plate in front of the scanner on  the found working distance (if you changed its position after the  projector focusing procedure.  Turn on the ​ C ross​   light mode and aim the scanner to the calibration plate. It is not  necessary to combine cross with marks on the plate at this stage, the focused projector  should be projecting a cross on any surface, located at the working distance from the  scanner.  Install the cameras in position, corresponding to selected scan area. To do this, unscrew  the mounting screws, move the camera to the desired position, and then put the screws  back. ...
  • Page 20: Final C Alibration

        Final calibration of the cameras  Make sure that the projected cross matches the blue grid and move on to the next step.            20 ...
  • Page 21 Adjust the lenses diaphragms. Set the exposure for the cameras between 30 and 60  (less if the object, which you are planning to scan is dark and more if it is bright). By  default the value is 45.  Areas​   ​ i lluminated​   ​ w ith​   ​ r ed​   ​ m ean​   ​ o verexposed​   ​ a reas​...
  • Page 22   If you are setting up the 4th scanning area, it may be necessary to decrease the  brightness of lines and stripes due to the close distance to object. In the menu  Brightness setup decrease the brightness value, as shown in the figure. Brightness value  of lines is approximately 2 times greater than the brightness of the stripes. Visually lines  and stripes must be the same brightness. ...
  • Page 23: Cameras Heating

    Cameras heating  Temperature of cameras can differ as much as 40° C between standby and active  modes. Ambient temperature of surrounding air has a great effect on time the cameras  need to get to an optimal working temperature.    If the cameras temperature has stabilized within ​ ±...
  • Page 24: Calibration P Late

      Calibrating the scanner  You​   ​ n eed​   ​ t o​   ​ p erform​   ​ c alibration​   ​ i n​   ​ o rder​   ​ t o​   ​ e nsure​   ​ t he​   ​ w ork​...
  • Page 25 For​   ​ e ach​   ​ s canning​   ​ z one​   ​ a ​   ​ s eparate​   ​ c alibration​   ​ p late​   ​ i s​   ​ u sed.​   ​ T here​  ...
  • Page 26: Full C Alibration

    Full calibration        Full​   ​ c alibration​   ​ d ialog​   ​ b ox​   ​ o pens​   ​ a utomatically​   ​ a fter​   ​ t he​   ​ C onfiguration​ ​ w izard​ , ​...
  • Page 27 In​ ​ a ccordance​ ​ w ith​ ​ t he​ ​ t ext​ ​ p rompt​ ​ a nd​ ​ s ymbol​ ​ i mage​ ​ i nstall​   ​ t he​ ​ c alibration​ ​ late  in​ ​ t he​ ​...
  • Page 28: Fast C Alibration

      After​   ​ a ll​   ​ t he​   ​ n ecessary​   ​ s napshots​   ​ a re​   ​ t aken,​   ​ w ait​   ​ f or​   ​ t he​   ​ r esult​...
  • Page 29   The​   ​ f ast​   ​ c alibration​   ​ c an​   ​ b e​   ​ a ccessed​   ​ rom  the​   ​ C alibration​   ​ w indow​   ​ o n​   ​ t he​...
  • Page 30: Focus Assessment During Calibration

    Focus assessment during calibration  While performing the calibration steps it is important to not deviate too much from the  working distance in order to keep the calibration field in focus.  The focus assessment option can help with this task. It is located in the ​ H ardware ...
  • Page 31                                                                     ​ RangeVision,​ 2 020   31 ...