Introduction Thank you for choosing RangeVision product. Please read this manual before using RangeVision 3D scanner. Here are described the procedures for preparing the scanner, installing the required drivers, calibration procedure, scanning procedure, and tips for acquiring high-quality three-dimensional object model. Information may be amended from time to time. These changes will be inserted into the ...
Specifications for PRO: FOV [L] [M] [S] Scanning area (WxHxD), 550х340х360 320х210х200 140х90х80 mm 3D-resolution, mm 0,18 0,10 0,04 Scanning distance, mm 900 520 350 Specifications for PRO Base: FOV [L] [M] [S] Scanning area (WxHxD), 520х390х360 280х210х200 115х85х80 mm 3D-resolution, mm 0,25 0,13 0,05 Scanning distance, mm 900 ...
System requirements: operating system - Windows 7/8/10 64bit, ● ● processor - Intel Core i3/i5 1.8 GHz and better, ● graphics card with HDMI output, RAM - not less than 8 GB. ● Preparing for work Package contents RangeVision 3D scanner is supplied in a plastic box with lodgement, optionally can be supplied in a protected road hard case. The scanner is equipped with at least one scanning area. Scanning area is a set of interchangeable optics, calibration plate and stand for the calibration plate. 5 ...
Page 6
№ Name qty. 1 Scanning module: Installation construction with projector 1 Cable kit for connection to a PC (2 USB + HDMI) 1 2 Machine vision camera 2 3 Tripod 1 4 Calibration plate 1-4* 5 Kit of interchangeable optics 1-5* 6 Stand for the calibration plate 1-2* 7 USB disk with the software 1 8 The electronic key 1 9 Matting spray 1 10 Markers for scanning 1 11 Power Cord 5 m 1 ...
Setting up your computer for the work with the scanner For t he c orrect o peration o f R angeVision 3 D s canner y ou w ill n eed t o s etup ...
Configuring computer parameters To avoid a recurrence of the problems during the scanner operation, you must turn off the screensaver and sleep mode. By clicking right mouse button on the desktop, select Personalize → Screensaver and turn off the screensaver, disable turning off the display and putting the computer in sleep mode. 9 ...
Scanner Assembly Carefully get the scanning module and all accessories out of the plastic case. Set the tripod on the flat and stable surface. Fit the scanning module on the tripod. Attach the cameras to the scanner, if they are not attached yet. Cameras must rotate around their axis facing each other, not in opposite directions. Install the camera lens kit (if not yet installed). Choice of lenses is described in the section dedicated to Scanner Setup. Connect USB cable to the scanner and to the computer. Connection should be made after the driver installation. Connect the power cord (220V) to the projector and turn on the main power. The switch is located on the bottom of the scanner next to USB, HDMI and power sockets. Connect HDMI cable to the scanner and to the computer. Turn on the projector by pressing the button on top of the scanning module. Insert the electronic key into a free USB port. Connect the rotary table (if equipped) to your computer using the USB cable. The TL model also requires to connect the power cord (3m cable). 10 ...
Select scanning zone After p reparatory a ctions o n s etting u p t he c omputer, y ou s hould c arry t he s canner ...
Lenses installing Set the cameras lenses, corresponding to the selected scanning zone. The scanning zone number is specified on the lens. Securely tighten the objectives. Try not to touch or let any dust on the objectives and cameras lenses. Blue Light For scanning with unfavorable external lighting conditions it is recommended to use the “blue light” technology (may not be included in the package. In order to do this Blue Light filters must be installed on the cameras lenses and the corresponding mode must be activated in ScanCenter NG options. Do not activate this mode with no filters installed and vice-versa. ...
Page 15
While i nstalling B lue L ight f ilters, b e g entle a nd d o n ot p ut...
Initial setup of cameras and lenses When you first set up the scanner, image from the cameras may be too bright or too dark due to different external lighting conditions. Adjust camera lenses, so that the brightness is acceptable: without the red overexposed areas and not too dark. Lens adjustment is carried out by rotating the ring on the objective. Loosen (do not unscrew!) the retention screw and rotate the ring. 16 ...
Adjustment of the projector focus During the scanner operation the projector projects structured light to the object - coded lines and stripes. To ensure that the lines are sharp, the projector must be focused on the working distance of the scanner. By switching the mode "Lines and Stripes", adjust the focus of the projector, so that the lines on the calibration plate were as sharp as possible. Using the zoom ring set the minimum possible area of projector light. ...
Bringing the cameras together For the work of the scanner it is necessary to point both cameras to the same position on the specified working distance. Install the calibration plate in front of the scanner on the found working distance (if you changed its position after the projector focusing procedure. Turn on the C ross light mode and aim the scanner to the calibration plate. It is not necessary to combine cross with marks on the plate at this stage, the focused projector should be projecting a cross on any surface, located at the working distance from the scanner. Install the cameras in position, corresponding to selected scan area. To do this, unscrew the mounting screws, move the camera to the desired position, and then put the screws back. ...
Final calibration of the cameras Make sure that the projected cross matches the blue grid and move on to the next step. 20 ...
Page 21
Adjust the lenses diaphragms. Set the exposure for the cameras between 30 and 60 (less if the object, which you are planning to scan is dark and more if it is bright). By default the value is 45. Areas i lluminated w ith r ed m ean o verexposed a reas...
Page 22
If you are setting up the 4th scanning area, it may be necessary to decrease the brightness of lines and stripes due to the close distance to object. In the menu Brightness setup decrease the brightness value, as shown in the figure. Brightness value of lines is approximately 2 times greater than the brightness of the stripes. Visually lines and stripes must be the same brightness. ...
Cameras heating Temperature of cameras can differ as much as 40° C between standby and active modes. Ambient temperature of surrounding air has a great effect on time the cameras need to get to an optimal working temperature. If the cameras temperature has stabilized within ±...
Full calibration Full c alibration d ialog b ox o pens a utomatically a fter t he C onfiguration w izard , ...
Page 27
In a ccordance w ith t he t ext p rompt a nd s ymbol i mage i nstall t he c alibration late in t he ...
Focus assessment during calibration While performing the calibration steps it is important to not deviate too much from the working distance in order to keep the calibration field in focus. The focus assessment option can help with this task. It is located in the H ardware ...