HINGMED WBP-02A User Manual

Wearable ambulatory blood pressure monitor

Advertisement

1639
Hingmed
Wearable Ambulatory Blood Pressure Monitor
User Manual
WBP-02A Hospital
Shenzhen Hingmed Medical Instrument Co., Ltd.
VER:A/3
Date: Jan, 2020
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WBP-02A and is the answer not in the manual?

Questions and answers

Summary of Contents for HINGMED WBP-02A

  • Page 1 1639 Hingmed Wearable Ambulatory Blood Pressure Monitor User Manual WBP-02A Hospital Shenzhen Hingmed Medical Instrument Co., Ltd. VER:A/3 Date: Jan, 2020...
  • Page 2 This manual may be upgraded due to software upgrading in the future. Users may not get further update for manual upgrading. ■ Version: A/1 ■ Issue date: Jan 2020 Shenzhen Hingmed Medical Instruments Co., Ltd. owns and reserves the copyright.
  • Page 3: Table Of Contents

    4.3.1 Hardware requirements..................13 4.3.2 Software requirements..................13 4.3.3 System installation....................13 4.4 Execute Ambulatory Blood Pressure Study ..............14 4.4.1 Communication with Hingmed ABPM.............. 14 4.4.2 Connect monitor to software system..............14 4.4.3 Programming......................14 4.4.4 Start automatic monitoring................. 15 4.4.5 Accomplish an automatic study................. 15 4.4.6 Retrieving data.....................
  • Page 4 Chapter 8 Warranty Card......................25...
  • Page 5: Chapter 1 Preface

    Chapter 1 Preface Brief Introduction of Ambulatory Blood Pressure Monitoring Ambulatory blood pressure monitor is an instrument for monitoring human’s blood pressure automatically during certain period (normally 1-2 days) with certain intervals upon actual situation. Blood pressure readings in different periods under different conditions would be analyzed and then blood pressure diagnosis would be given accordingly.
  • Page 6 For the following hypertension types, Ambulatory blood pressure monitoring is particularly helpful for diagnosis. 1. White-coat hypertension White-coat hypertension is for the cases that the blood pressure is constantly high in hospital or clinic office but normal out of hospital or clinic office. And this kind of situation is repeatable.
  • Page 7: Chapter 2 Safety Requirements

    Hingmed WBP-02A Hospital ABPM is wearable. Comparing traditional ABPM, it’s very small, light and is worn on people’s arm directly without air tube. The traditional ABPM used to be attached with a 1 meter longer air tube around patient body. WBP-02A Hospital has below strength: 1.
  • Page 8: Contraindication

    2.2 Contraindication ● DO not use the monitor near X-ray tomography device. ● DO not use the monitor in the places where inflammable anesthetic exist, it may lead to explode. ● DO not wrap the cuff on the limb being used for IV injection as cuff inflation may block infusion and hurt patient.
  • Page 9: Notice

    ● Please properly handle the scrapped batteries, cuff, cable and main units in compliance with local environmental regulations. 2.4.5 Maintenance ● Please use the accessories supplied by Hingmed, otherwise it may cause measurement errors. ● Maintenance should be conducted only by trained personnel or personnel authorized by Hingmed.
  • Page 10: Chapter 3 Product Introduction

    Chapter 3 Product Introduction 3.1 Product composition: Prior to use please confirm if any accessories are missed, if there is any damage on main unit and accessories, please contact distributors or Hingmed customer service for help. Hingmed ABPM Packing List Accessories Items Name...
  • Page 11: Display

    3.2.2 OLED Displays Quantities of historical memory, it flashes means full of memory Automatic measurement Showing system time when turning on Heartbeat symbol Measurement time of history memory Battery volume indication 3.2.3 Symbols Symbol Description Symbol Description CF type applied part Series number Attention, refer to accompanying Manufacturer...
  • Page 12: Wearing The Monitor

    USB cable. Note: The quick charger attached in WBP-02A package is a special designed quick charger. Please always use this charger for battery charging. 4.2 Wear the monitor With the special integration design, you can wear the Hingmed WBP-02A Hospital ABPM on your arm.
  • Page 13: System Installation

    If the CD cannot run automatically, operate as following steps: a) Open “My computer” or “Computer”; b) Click CD drive and find Hingmed installation software(Network version or SSingle terminal version upon your requirement). c) Double-click “set up” follow the instructions → “Next” → “Next”, select the language item (Chinese or English), click “Next”...
  • Page 14: Execute Ambulatory Blood Pressure Study

    Hingmed PC software. Note: USB cable should disconnect with computer after installation. 4.4 Execute Ambulatory Blood Pressure Study 4.4.1 Communication with Hingmed ABPM After installing the PC software, your computer should be able to communicate with monitor for programming and performing a Ambulatory Blood Pressure Monitoring study.
  • Page 15: Start Automatic Monitoring

    4.4.5 Finish measurement If the measurement is accomplished, take it off from the patient. 4.4.6 Retrieve data 1. Connect the monitor to computer through USB port; 2. Open Hingmed ABPM software;...
  • Page 16 3. click “Read” to transmit the data, the data will be shown on the screen automatically after successful “reading”, and then you can analyze the data on the software. See Figure Note: Data will be missed after next programming operation if they are not uploaded to computer.
  • Page 17 Figure c: Ambulatory blood pressure history data analysis summary map Note: 1. For operation details of PC software of Hingmed Wearable Ambulatory Blood Pressure Monitor, please refer to < User Guide of PC software >; 2. Programming the monitor will delete the history data in the monitor, so please make sure that the history data has been retrieved and stored;...
  • Page 18: Chapter 5 Troubleshooting And Maintenance

    Press “start/stop” button to measure EC37 Overtime (beyond 180s) again. Upload and program the machine to EC48 Memory is full, can no longer measure release the memory. * If the errors cannot be fixed by yourself, please call distributor or service of Hingmed.
  • Page 19: Maintenance

    Visually check if there is any broken or damages on enclosure and cuff. If any damage is found, do not use the monitor. Please contact the distributor or the after-sale service department of Hingmed. 5.2.2 Monitor Maintenance After use, it is important to perform preventative maintenance to ensure the safe and efficient operation of the monitor for long-term.
  • Page 20: Chapter 6 Product Specifications

    Chapter 6 Product specifications Name Wearable Ambulatory Blood Pressure Monitor Model WBP-02A Hospital Measurement technology Oscillometric Systolic blood pressure 40-260 mmHg measurement range Diastolic blood pressure 20-210 mmHg measurement range...
  • Page 21: Chapter 7 Emc Information

    Guidance and manufacture’s declaration – electromagnetic emission is intended for use in the electromagnetic environment specified below. The customer of WBP-02A the user of the should assure that it is used in such an environment.
  • Page 22 Guidance and manufacture’s declaration – electromagnetic immunity The WBP-02A is intended for use in the electromagnetic environment specified below. The customer or the user of WBP-02A should assure that it is used in such an environment. IEC 60601 test Compliance...
  • Page 23 Portable and mobile RF communications equipment should be used no closer to any part of the WBP-02A, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance...
  • Page 24 Portable and mobile RF communications equipment and the WBP-02A . The WBP-02A is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the WBP-02A can help prevent electromagnetic interference by...
  • Page 25 Dealer: Tel: Postal Code: Dealer stamp: The limited liability of guarantee Hingmed provides the original purchaser the following limited warranty from the date of invoicing. Hingmed Wearable ambulatory blood pressure monitor………………………… 24 months Accessories except cuff………………………………………………………………90 days Cuff..………………………………………………………………..……………………6 months Hingmed warrants each monitor to be free from defects in material and workmanship.

Table of Contents