Yoshitake MS-6 Instruction Manual

Yoshitake MS-6 Instruction Manual

Noiseless heater

Advertisement

Quick Links

Thank you very much for purchasing our Noiseless Heater.
Please read this instruction manual thoroughly before using the Noiseless Heater, so that
you may do so correctly and safely. Please carefully store this manual in a handy place.
------The following safety symbols are used in this manual.-----
Warning
Caution
1. Specifications ······························································ 1
2. Dimensions and weights ··············································· 1
3. Nominal size selection method ···································· 2~3
4. Noise characteristics charts ········································ 3~4
5.1 Precaution for installation········································ 5
5.2 Example of piping ··················································· 5
5.3 Precaution for operation ············································ 5
After sales service
Noiseless Heater
Instruction Manual
This symbol indicates a potentially hazardous situation that, if not
avoided, could result in death or serious injury.
This symbol indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury. ("Caution" may also be used to
indicate other unsafe practices or risks of property damage.)
MS-6
Contents
■EPDT-055a■

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Yoshitake MS-6

  • Page 1 MS-6 Noiseless Heater Instruction Manual Thank you very much for purchasing our Noiseless Heater. Please read this instruction manual thoroughly before using the Noiseless Heater, so that you may do so correctly and safely. Please carefully store this manual in a handy place.
  • Page 2 1. Specifications Fluid Steam Nominal size 15A-50A Pressure range 0.05~0.7 MPa Maximum warning sound 90℃ temperature limit Material Stainless steel Connection JIS Rc screwed 2.2 Dimensions and weights (mm) Nominal Weight size (kg) Rc1/2 48.5 0.25 Rc3/4 44.5 0.40 0.52 Rc1 1/4 0.77 Rc1 1/2...
  • Page 3 3 Nominal size selection method Nominal size selection chart Formula for calculating the required nominal size The steam volume “W” required to raise the temperature of “Q” amount of water by “B” degrees Celsius in “A” amount of time is calculated as follows: W:Steamvolume(kg/h) Q:Water volume(kg) B:DesiredTemp.rise(℃)
  • Page 4 Nominal size calculation example When the temperature of 7000kg of water is to be raised from 20 to 60℃ over a period of 1 hour, with a steam pressure of 0.5MPa,the nominal size is calculated as follows: 7000 =560 (kg/h) Referring to the “Norminal Selection”...
  • Page 5 Steam Pressure : 0.5MPa *The noise characteristics indicated in the above charts may vary somewhat depending on the tank size and shape, and on the noiseless heater’s mount position,etc. *Noise is measured at a point 1 meter above the waterline. ■EPDT-055a■...
  • Page 6 5. Installation and operation 5.1 Precautions for installation Caution (1) The noiseless heater should be mounted 300mm or more from the tank’s walls and bottom. (Refer to 5.2 Example of piping) * Vibration may occur in a tank by the flow of a liquid. (2) Use it within the maximum warning sound temperature limit.

Table of Contents