Advertisement
1 x indoor station ISW5410-0145
1 x Mounting plate with connection terminal
1 x CAT cable with RJ45 socket
1 x product information (brief)
1 x user manual
Assembly, installation, commissioning and repair of electronic devices must be carried out by qualified electricians. Observe the latest regulations and standards for system installations.
Danger due to electrical shock.
Observe the safety regulations according to DIN VDE 0100, when working on main power connections of 230 V.
When installing TCS:BUS systems the general safety regulations for telecommunication systems according to VDE 0800 must be observed. Among them:
Device damage due to overvoltage.
By suitable lightning protection measures it has to be ensured that the electric voltage of 32 V DC at each connection is not to be exceeded.
The ISW5410-0145 is an IP audio indoor station for full duplex VoIP hands-free talking. The device is exclusively suitable for indoor usage. Type of mounting: surface-mount.
For applications, which differ from the intended use or goes beyond it, the manufacturer accepts no liability.
Supply voltage: 8 - 26 V DC (DC power supply), IEEE802.3af (PoE), I(P) in resting position: 42 mA, I(Pmax): 175 mA
Degree of protection: IP30
Ambient temperature: - 5...+ 40°C
Housing: plastics ASA
Dimensions (in mm): H 194 x W 94 x D 17 (mounting plate), T 21 (mounting tray)
Weight: 190 g (incl. mounting plate)
Supported protocols: IPv4, TCP, UDP. DHCP, HTTP, HTTPs, SIP 2.0 (UDP), RTP, Syslog, ICMP and ARP
Audio codecs: G.711a/µ, G.722
Audio transmission: full duplex
For an optimal operation, install the video indoor station 1.60 m (upper edge of the device) above the ground).
Set a flush-mount socket to stow the wires. Connect the wires according to the labelling on the mounting plate: ERT, P, P, GND, ETH_TX+, ETH_TX-, ETH_RX+ und ETH_RX- (top down).
Observe the installation position of the mounting plate. It is marked by an arrow and the designation TOP.
If the installation of a flush-mounted socket is not possible, use the mounting tray. The mounting tray is available as accessory (article: ZIA5002-0145).
Insert a screw driver with slight pressure into the release opening (1). Pull off the device to the front at its upper side. Lift the device out of the adjustment increments (2).
Put the device onto both adjustment increments of the mounting plate (1). Press the device against the latch until it snaps on (2).
The IP indoor station obtains the network address automatically, if a DHCP server exists. If this is not the case, you can set the network address manually via the configuration software.
After a voltage breakdown the IP indoor station restarts automatically. Switching off the power supply during a saving procedure or software update can cause a loss of data or a technical defect of the device. We are continually improving our products. We recommend that you visit our homepage regularly in order to find software updates for your device.
Detailed information on terms of service for IP-enabled systems you'll find at: http://www.tcsag.de/fileadmin/user_upload/Servicebedingungen-IP_uk.pdf
If the IP indoor station recognises an error, the error is indicated when alls LEDs are flashing. Pressing any button of the device triggers the output of an error tone. The optical error indication stays active as long as the error has been corrected.
Error tone | ![]() |
Error causes | button stuck (was pressed longer than 15 s) |
Troubleshooting | loosen the button at the device or floor push button, device is in stand-by mode again |
Error tone | ![]() |
Error causes | no Ethernet |
Troubleshooting | check the connecting cable |
Error tone | ![]() |
Error causes | conflict with IP address |
Troubleshooting | check the settings |
Error tone | ![]() |
Error causes | no DHCP |
Troubleshooting | check the settings |
Error tone | ![]() |
Error causes | no SIP server |
Troubleshooting | check the connecting cable and the settings |
Error tone | ![]() |
Error causes | no TCS:Server / BVS-IP |
Troubleshooting | check the connection cable and settings |
The ring tone setting can be blocked via the configuration software.
Detailed information on IP settings and the operation of the configuration software you'll find in the manual of the configuration software configo-IP. Scan the following QR code to download the manual. Alternatively click the QR code. You'll be forwarded to the download.
Declarations of conformity are available for download www.tcsag.de/en/.
Dispose the device separately from domestic waste via a collection point for electronic scrap. Ask your county administration for the responsible collection point.
Dispose the parts of the packaging in collecting tanks for cardboard and paper resp. plastics.
For detailed information visit our website www.tcsag.de/en/ Download or scan the QR code.
HOTLINE
Phone +49 4194 9881-188
Fax +49 4194 9881-189
E-Mail hotline@tcsag.de
SALES
Phone +49 4194 9881-144
Fax +49 4194 9881-149
E-Mail sales@tcsag.de
ORDER DIVISION
Phone +49 4194 9881-166
Fax +49 4194 9881-169
E-Mail offer@tcsag.de
TRAINING COURSES
Phone +49 4194 9881-155
Fax +49 4194 9881-159
E-Mail schulungen@tcsag.de
TCS TürControlSysteme AG
Geschwister-Scholl-Straße 7
D-39307 Genthin
Phone: +49 3933 8799-10
Fax: +49 3933 8799-10
TCS Österreich GmbH
Gewerbepark 21
A-2821 Lanzenkirchen
Printout: 07/2017 | Subject to technical changes.
kPI_ISW5410-0145 1 A
www.tcsag.de
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the TASTA Series and is the answer not in the manual?
Questions and answers