SCOPE OF DELIVERY

1 x indoor station ISW5410-0145
1 x Mounting plate with connection terminal
1 x CAT cable with RJ45 socket
1 x product information (brief)
1 x user manual

SAFETY INSTRUCTIONS

General safety instructions

information Assembly, installation, commissioning and repair of electronic devices must be carried out by qualified electricians. Observe the latest regulations and standards for system installations.


Danger due to electrical shock.
Observe the safety regulations according to DIN VDE 0100, when working on main power connections of 230 V.

information When installing TCS:BUS systems the general safety regulations for telecommunication systems according to VDE 0800 must be observed. Among them:

  • separated cable routing of high and low voltage lines,
  • minimum distance of 10 cm in case of a common cable routing,
  • use of separators between high and low voltage lines within shared cable ducts,
  • use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
  • already existing lines (modernisation) with deviating cross-sections can be used in compliance with the loop resistance.
  • Observe the generally accepted standards for structured wiring of communication systems according to EN50173-1 when installing TCS:VoIP devices. Always use data cables with the standard CAT5e at least.

    Ensure, that the VoIP communication of TCS devices is not encoded. Protect your network and WLAN from unauthorised access.
  • Change the password after the commissioning.
  • Be careful when linking-up the device to the internet. Ask your network administrator.

Requirements to protect against lightning


Device damage due to overvoltage.
By suitable lightning protection measures it has to be ensured that the electric voltage of 32 V DC at each connection is not to be exceeded.

PRODUCT DESCRIPTION

Intended use

The ISW5410-0145 is an IP audio indoor station for full duplex VoIP hands-free talking. The device is exclusively suitable for indoor usage. Type of mounting: surface-mount.

information For applications, which differ from the intended use or goes beyond it, the manufacturer accepts no liability.

DEVICE OVERVIEW

Overview

INDICATION AND OPERATING ELEMENTS

    • Send HTTP request
    • Send DTMF string
    • SIP call 1 to other indoor stations or concierge
    • Ring tone selection: internal call
    • Stand-by mode: send HTTP(s) request
    • Active voice connection: send HTTP(s) request or DTMF command sequence
    • Send SIP call 2
    • In central operation mode (central server) door release automatic activated / deactivated
    • Press longer than 3 s: activate / deactivate ambient illumination
    • Ring tone selection for SIP address group 2
    • Door release
    • In stand-by mode: send HTTP(s) request, send HTTP(s) string 3
    • In speech mode: send DTMF command or HTTP(s) request
    • Terminate speaking: voice connection is terminated automatically after 4 s
    • Ring tone selection for unknown SIP address
    • OFF: door opener is ready for operation
    • ON for 3 s, gate is opened
    • Blinks: call display, when configured
    • OFF: temporary (manually) or permanently switched off
    • ON: temporary (manually) or permanently switched on
    • OFF: ready for operation
    • ON: call, speaking is active
    • Blinks: busy speech channel
    • Shortly press: call acceptance, activate speaking
    • Terminate speaking
    • Ring tone selection: SIP address group 1
    • Setting the ring tone volume in 4 steps, if no voice connection is established.
    • Setting the volume of the voice output in 4 steps when a voice connection is established.
    • OFF: call OFF is deactivated
    • ON: call OFF is activated
    • For additional signalling of the door call, can be ordered as accessory
    • Shortly press: ring tone off
    • Press for 8 s: initiate / terminate the ring tone selection mode

TECHNICAL DATA

Supply voltage: 8 - 26 V DC (DC power supply), IEEE802.3af (PoE), I(P) in resting position: 42 mA, I(Pmax): 175 mA

Degree of protection: IP30

Ambient temperature: - 5...+ 40°C

Housing: plastics ASA

Dimensions (in mm): H 194 x W 94 x D 17 (mounting plate), T 21 (mounting tray)

Weight: 190 g (incl. mounting plate)

Supported protocols: IPv4, TCP, UDP. DHCP, HTTP, HTTPs, SIP 2.0 (UDP), RTP, Syslog, ICMP and ARP

Audio codecs: G.711a/µ, G.722

Audio transmission: full duplex

MOUNTING AND INSTALLATION

Mounting height

For an optimal operation, install the video indoor station 1.60 m (upper edge of the device) above the ground).
Mounting Height

Install the mounting plate

Set a flush-mount socket to stow the wires. Connect the wires according to the labelling on the mounting plate: ERT, P, P, GND, ETH_TX+, ETH_TX-, ETH_RX+ und ETH_RX- (top down).

information Observe the installation position of the mounting plate. It is marked by an arrow and the designation TOP.

Install the Mounting Plate

Install the mounting tray

information If the installation of a flush-mounted socket is not possible, use the mounting tray. The mounting tray is available as accessory (article: ZIA5002-0145).

Remove the device

Insert a screw driver with slight pressure into the release opening (1). Pull off the device to the front at its upper side. Lift the device out of the adjustment increments (2).
Remove the Device

Snap-on the device

Put the device onto both adjustment increments of the mounting plate (1). Press the device against the latch until it snaps on (2).
Snap-on the Device

Example circuit

Example Circuit

COMMISSIONING

System requirements

  • operating system Windows 7, 8, 8.1 or 10
  • required hard disk space: 10 MB
  • graphic card with at least 1280x1024 pixel
  • Net Framework 4.0

Preparations

  • switch (PoE) or router
  • a Windows PC with network
  • configuration software (not enclosed in the delivery)

Configuration software configo IP

  • Download the configuration software directly from the homepage of the TCS AG.
  • Unpack the ZIP file on your hard disk.
  • Start the Configo_IP_1.0.0.5.exe. You'll be guided through the installation at the screen.

Establish a network connection

  • Install the devices of the system completely.
  • Check the wires against each other on short-circuit.
  • Ensure, that an external voltage source is available or the the supply via PoE is ensured.
  • Connect the IP indoor station via network cable to your network (PoE switch, router).
  • Connect the Windows PC to your network.
  • Switch on the voltage supply.

information The IP indoor station obtains the network address automatically, if a DHCP server exists. If this is not the case, you can set the network address manually via the configuration software.

information After a voltage breakdown the IP indoor station restarts automatically. Switching off the power supply during a saving procedure or software update can cause a loss of data or a technical defect of the device. We are continually improving our products. We recommend that you visit our homepage regularly in order to find software updates for your device.

information Detailed information on terms of service for IP-enabled systems you'll find at: http://www.tcsag.de/fileadmin/user_upload/Servicebedingungen-IP_uk.pdf

Error detection and indication

information If the IP indoor station recognises an error, the error is indicated when alls LEDs are flashing. Pressing any button of the device triggers the output of an error tone. The optical error indication stays active as long as the error has been corrected.

Error tone
Error causes button stuck (was pressed longer than 15 s)
Troubleshooting loosen the button at the device or floor push button, device is in stand-by mode again
Error tone
Error causes no Ethernet
Troubleshooting check the connecting cable
Error tone
Error causes conflict with IP address
Troubleshooting check the settings
Error tone
Error causes no DHCP
Troubleshooting check the settings
Error tone
Error causes no SIP server
Troubleshooting check the connecting cable and the settings
Error tone
Error causes no TCS:Server / BVS-IP
Troubleshooting check the connection cable and settings

OPERATION

Ring tone selection

  • Press the call-OFF button for 8 seconds. All LEDs are on and an acknowledgment tone sounds. The ring tone selection is activated.
  • Press the door release button to select the ring tone for unknown SIP calls.
  • Press the speech button to select the ring tone for the SIP address group 1.
  • Press the function button 1 to select the ring tone for the SIP address group 2.
  • Press the function button 2 to select the ring tone for floor calls.
  • Press the call-OFF button or wait for 8 seconds without any further action to terminate the ring tone selection. All LEDs expire.

information The ring tone setting can be blocked via the configuration software.

Ambient illumination

  • Press the function button 2 for around 4 seconds. The ambient illumination is (de-)activated.

Configuration software configo-IP

information Detailed information on IP settings and the operation of the configuration software you'll find in the manual of the configuration software configo-IP. Scan the following QR code to download the manual. Alternatively click the QR code. You'll be forwarded to the download.

NOTES

Conformity


Declarations of conformity are available for download www.tcsag.de/en/.

Information on disposal


Dispose the device separately from domestic waste via a collection point for electronic scrap. Ask your county administration for the responsible collection point.


Dispose the parts of the packaging in collecting tanks for cardboard and paper resp. plastics.

Service

For detailed information visit our website www.tcsag.de/en/ Download or scan the QR code.

HOTLINE
Phone +49 4194 9881-188
Fax +49 4194 9881-189
E-Mail hotline@tcsag.de

SALES
Phone +49 4194 9881-144
Fax +49 4194 9881-149

E-Mail sales@tcsag.de

ORDER DIVISION
Phone +49 4194 9881-166
Fax +49 4194 9881-169

E-Mail offer@tcsag.de

TRAINING COURSES
Phone +49 4194 9881-155
Fax +49 4194 9881-159

E-Mail schulungen@tcsag.de

TCS TürControlSysteme AG
Geschwister-Scholl-Straße 7
D-39307 Genthin

Phone: +49 3933 8799-10
Fax: +49 3933 8799-10

TCS Österreich GmbH
Gewerbepark 21
A-2821 Lanzenkirchen

Printout: 07/2017 | Subject to technical changes.
kPI_ISW5410-0145 1 A
www.tcsag.de

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download TCS TASTA Series, ISW5410-0145 Manual

Advertisement

Need help?

Need help?

Do you have a question about the TASTA Series and is the answer not in the manual?

Questions and answers

Table of Contents