Voltage Measurement; Main Unit (Su-Htb885) - Panasonic SU-HTB885EB Service Manual

Table of Contents

Advertisement

14 Voltage Measurement

Note:
• Indicated voltage values are the standard values for the unit measured by the DC electronic circuit tester (high-impedance) with
the chassis taken as standard.
Therefore, there may exist some errors in the voltage values, depending on the internal impedance of the DC circuit tester.
• Circuit voltage and waveform described herein shall be regarded as reference information when probing defect point because it
may differ from actual measuring value due to difference of Measuring instrument and its measuring condition and product itself.

14.1. Main Unit (SU-HTB885)

14.1.1. PANEL P.C.B./BUTTON P.C.B./OPTICAL JACK P.C.B.
REF NO.
MODE
1
2
POWER
3.4
0
3.4
STANDBY
3.4
0
3.4
REF NO.
MODE
1
2
PLAY
0
3
STANDBY
0
3
REF NO.
MODE
1
2
PLAY
3.3
3.3
STANDBY
3.3
3.3
Q
3
3
0
0
REF NO.
MODE
E
C
PLAY
5.9
12.7
5.8
STANDBY
5.9
12.7
5.8
REF NO.
MODE
1
2
PLAY
0.2
0.2
0.2
STANDBY
0.2
0.2
0.2
REF NO.
MODE
1
2
PLAY
0
3.3
2.2
STANDBY
0
3.3
2.2
REF NO.
MODE
1
2
PLAY
3.3
3.3
STANDBY
3.3
3.3
Q1500
REF NO.
MODE
E
C
PLAY
0
1.4
STANDBY
0
1.4
3
4
5
6
3.4
3.4
3.4
3.4
3.4
3.4
3
4
5
0
3.3
3.3
0
3.3
3.3
3
4
5
0
0
3.3
0
0
3.3
Q
3
3
0
1
B
E
C
B
5.9
0
5.8
5.9
0
5.8
3
4
5
6
7
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Q6101
3
4
5
6
3.1
3.3
3.3
3.1
3.3
3.3
3
4
5
6
7
0
3.3
3.3
0
0
0
3.3
3.3
0
0
B
0
0
IC3300
IC3301
IC3302
Q
3
3
0
2
1
2
3
4
5
0
5
0
5
0
5
0
SC-HTB885EB/EG (SU-HTB885EB/EG) PANEL P.C.B.
IC6102
8
9
10
11
12
0
3.3
3.3
3.3
3.3
0
3.3
3.3
3.3
3.3
SC-HTB885EB/EG (SU-HTB885EB/EG) BUTTON P.C.B.
IC1501
8
9
10
11
12
3.3
0
0
3.3
3.3
3.3
0
0
3.3
3.3
SC-HTB885EB/EG (SU-HTB885EB/EG) OPTICAL JACK P.C.B.
75
Q
3
3
0
5
1
2
3
0
5
1.7
5
0
5
1.7
5
13
14
15
16
17
0
1.8
3.3
3.3
0
0
1.8
3.3
3.3
0
13
14
0
3.3
0
3.3
3
4
5
1.7
1.7
1.7
1.7
18
19
20
0
0.2
0.2
0
0.2
0.2

Advertisement

Table of Contents
loading

Table of Contents