Advertisement

4.2.4 Sensor Options

Quality assurance
Probe rod lengths
Hazardous zones classification

4.2.5 Cabling

All cabling must be suitable for use in hazardous zones.
Cabling should be rated for use up to +65°C (150°F) at least to allow for an ambient temperature of up to +50°C
(120°F). Cables supplied by Goyen | Mecair meet these requirements.
The power-supply cord shall be not lighter than a light PVC-sheathed flexible cord according to IEC 60227
(designation H03 VV-F or H03 VV H2-F).
The conductor area shall be no less than 0.75 mm².
For special instructions and requirements relating to the installation of sensors in hazardous zones refer to the
Sensor Safety Description on page 4 and to the Sensor Installation section on page 9.
Maximum cable lengths
08
INSTALLATION AND OPERATION MANUAL – OWNER'S RECORD PEM MANUAL – PARTICULATE EMISSION MONITOR
• Electronic drift checks (manual)
• Short-circuit check
100 mm (4"), 200 mm (8"), 300 mm (12"), 400 mm (16"), 500 mm (20"), 600 mm (24"),
800 mm (32"), 1000 mm (40").
Note: Imperial measurements are nominal values.
ATEX dust zone 22 (Cat. 3)
RS-485: 1,000 m (0.6 mi/3,300 ft, nom.)