1) OVERVIEW Thank you for choosing the M MM100 automatic liquid level chemical proportioner. The AGIK INDER is a non-electric device that automatically maintains the level and concentration of a AGIK INDER solution reservoir. To obtain the best performance from you M , please read the instructions AGIK INDER...
Page 3
Mount the M in a level position on edge of solution reservoir. U-Clamp (MM4b) may AGIK INDER be repositioned or removed as shown in the following diagram. Ensure open end of discharge tube empties into solution reservoir. Insert foot valve end of suction tube into chemical concentrate container. The level of the concentrate must be below the level of M or it will continue to draw after it is turned AGIK...
Red or White (drilled with 74) 80:1 Red or White (drilled with 76) 104:1 Red or White (drilled with 79) 160:1 Red or White (drilled with 87) 256:1 6) MEASUREMENT OF CONCENTRATION & GUIDE TO TIP SELECTION The water-to-product ratio is calculated using the number of ozs. of chemical concentrate drawn by the proportioner to produce a measured volume of mixed solution.
8. TROUBLESHOOTING Problem Cause Remedy •No discharge. a) No water. a) Open water inlet valve. b) Defective magnetic valve b) Replace assembly. assembly. c) Install regulator if pressure c) Excessive water pressure. exceeds 85 PSI. •No chemical draw. a) Clogged foot valve strainer. a) Clean or replace.