ANMX Installation, use and maintenance handbook ANMX 308 ANMX 309 ANMX 311 ANMX 312 COD: 5561499 REV:1 10-2016...
Page 2
CONFORMANCE STATEMENT his appliance has been manufac- tured with suitable materials for use with drinking water. he device conform to L.D. 108 dated 25.01.1992. (87/308/CEE) and has been approved by the WRAS (WATER REGULATION AD- VISORY SCHEME) his product has been designed, manufactured and placed on the market complying with the following APPLIANCE DATA PLATE...
REMOVAL OF PACKAGING • P lace the appliance in its installation site (chap. 5 - INSTALLATION). roduct • C ut straps and remove carton , polystyrene and external plastic his appliance is marked according to the European directive 2012/19/ UE on Waste Electrical and Electronic Equipment (WEEE). y ensuring • D o away with plastic bags...
ANMX ANMX 308 - 309 308 - 309 311 - 312 DESCRIPTION OF THE APPLIANCE hese water coolers were designed to offer maximum hygiene and easy maintenance. hey are sturdy and have a high level of performance. he direct cooling system (made from non-oxidising steel aisi 316L) guarantees an optimal hygiene for factories, offices, communities and public places.
Reserved to qualified operators Attention: To carry out this or any other maintenance operation requiring the machine casing to be opened, use protective gloves to avoid being cut by the sharp edges of the sheet steel. INSTALLATION ANMX 311 - 312 Place the appliance in the desired point of installation, away from heat sources and protected from direct sunrays.
Page 8
Reserved to qualified operators INSTALLATION is between 1 and 3 bars: ASSEMBLY AND ADJUSTMENT OF THE FAUCETS • If the mains water pressure exceeds 3 bars, predispose a pressure re- Faucet G61 - Insert the lever and let it glide on the specific guiding channel, ducer capable of reducing the latter to the 1-3 range (Fig. 12). attach the tube, and tighten it. The water flow is pre-set by the manufacturer.
Reserved to qualified operators Connect the machine to a mains electrical network protected by a circuit breaker with a sensitivity equal to or less than 30 mA. Warning! If the power cable is damaged, it must be replaced by the manufacturer, by an authorized technical assistance provider or else by an individual with similar qualifications, in order to prevent any risks.
Page 10
Reserved to qualified operators INTERNAL CLEANING/ HYGIENIC CLEANING WARNING! Considering that the products used for the hygienic cleaning are acid and alkali corrosive substances, disposable gloves must be used as well as glasses to protect your eyes. When this hygienic cleaning is carried out, you must keep to the product reaction times, percentages of hygienic detergent and quantity of water necessary for rinsing.
Page 11
Reserved to qualified operators 17.1 17.2 17.3 17.4 17.5 HOW TO REPLACE THE FILTER CARTRIDGE • There may be a small amount of water during cartridge removal. • Push the new cartridge into filter head and turn until it stops (Fig. 17.4). Attention!: to carry out this or any other maintenance • Turn the lever in horizontal position and check if there’re water leaks operation requiring the machine casing to be opened, use (Fig.
The temperature adjuster is faulty and causes Make the ice melt. complete freezing of the ice compartment. Replace the temperature adjuster. Qualified operator service: Franke Sissons Ltd. Carrwood Road, Sheepbridge, Chesterfield, S41 9QB Telephone: 01246 450255 Fax: 01246 451276 E-mail: ws-info.uk@franke.com...