Ascon tecnologic K V Series Quick Manual

Ascon tecnologic K V Series Quick Manual

Indicators with independent timer option

Advertisement

Quick Links

KxxV
Indicators
with independent Timer option
Quick Guide -Code: FKxxVENG
Ascon Tecnologic S.r.l
Via Indipendenza, 56
27029 Vigevano (PV) - ITALY
Tel.: +39 0381 69871
FAX: +39 0381 698730
http:\\www.ascontecnologic.com
info@ascontecnologic.com
1 - OUTLINE DIMENSIONS (mm)
1.1 K3_V Series
78
5.5
64
Brackets
71
1.2 K4_V Series
48
9.5
98
Panel + Gasket
Bracket
9 mm max.
type 1
1.3 K85V Series
70
27
21
12
1 2 3
4 5 6 7 8 9 10 11 12
Out1 Out2
Out3
13 14 15 16 17 18 19 20 21 22 23 24

2 - CONNECTIONS DIAGRAMS

2.1 K31V Series
0... 50/60 mV; 0... 1 V; 0/1... 5 V; 0/2... 10 V
0/4... 20 mA active
4... 20 mA active
Ext.
gen.
4... 20 mA passive (2 wires)
PTC-NTC
DI1
DI2
RS485
Pt100
B
GND A
TC/mV
RELAYS: Out-1, 2: 8A-AC1 (3A-AC3)/250VAC
SSR: 10mA/10VDC
RELAYS: Out-3, 4: 5A-AC1 (2A-AC3)/250VAC
Power
OUT4
OUT3
OUT2
OUT1
supply
2.2 K38V Series
RELAY: 8A-AC1 (3A-AC3)/250VAC
SSR: 8mA/8VDC
NC NO C
NC NO
INPUT
C
OUT1
OUT2
Power
supply
Out 10VDC max. 20mA
4...20 mA passive (2 wires)
Ext.
4...20 mA active
gen.
0/4...20 mA active
0...50/60 mV; 0...1 V;
0/1...5 V; 0/2...10 V
2.3 K4_V Series
Out1, Out2: Relay 8A-AC1 (3A-AC3)/250VAC
Out3: Relay 5A-AC1 (2A-AC3)/250VAC
SSR: 8mA/8VDC
DI1
DI2
INPUT
TC
OUT3
OUT2
Power
Pt100
supply
PTC-NTC
Out 12 VDC max. 20 mA
4...20 mA passive (2 wires)
4... 20 mA active
Ext.
gen.
0/4...20 mA active
0... 50/60 mV; 0... 1 V; 0/1... 5 V; 0/2... 10 V
2.4 K85V Series
0... 50/60 mV; 0... 1 V; 0/1... 5 V; 0/2... 10 V
0/4... 20 mA active
4... 20 mA active
4... 20 mA passive (2 wires)
DI1
DI2
Power
A
B
supply
Digital input
RS485
Relays: Out-1, 2: 8A-AC1 (3A-AC3)/250VAC
Out-3: 5A-AC1 (2A-AC3)/250VAC
OUT1
OUT3
Note: The complete manual is available, free of
charge, at:
www.ascontecnologic.com

2.5 Mounting requirements

This instrument is intended for permanent installa-
tion, for indoor use only, in an electrical panel which
encloses the rear housing, exposed terminals and
wiring on the back. Select a mounting location hav-
ing the following characteristics:
1. It should be easily accessible;
2. There is minimum vibrations and no impact;
3. There are no corrosive gases;
4. There are no water or other fluid (i.e.
condensation);
5. The ambient temperature is in accordance with
the operative temperature (0... 50 °C)
6. The relative humidity is in accordance with the
instrument specifications (20... 85 %)
The instrument can be mounted on panel with a
maximum thick of 15 mm. When the maximum front
protection (IP65) is desired, the optional gasket
must be monted.
2.6 Genereal notes about wiring
1. Do not run input wires together with power cables;
2. External components (like zener barriers, etc.)
connected between sensor and input terminals
may cause errors in measurement due to
excessive and/or not balanced line resistance or
possible leakage currents;
3. When a shielded cable is used, it should be
connected at one point only;
4. Pay attention to the line resistance; a high line
resistance may cause measurement errors.
5. Before connecting the instrument to the power
line, make sure that line voltage is equal to the
Bracket
voltage shown on the identification label.
type 2
6. The power supply input is NOT fuse protected.
Please, provide a T type 1A, 250 V fuse externally.
Notes:Safety precautions.
a) To avoid electrical shock, connect power at last;
b) For supply connections use No. 16 AWG or lar-
ger wires rated for at last 75°C;
c) Use copper conductors only;
d) Before connecting the instrument to the power
line, make sure that line voltage is equal to the
voltage shown on the identification label.
e) The power supply input is NOT fuse protected.
Please, provide a T type 1A, 250 V fuse exter-
nally.

3 - CONFIGURATION PROCEDURE

3.1 How to enter the configuration mode

1. Push the
button for more than 3 seconds.
The display will show alternately 0 and PASS;
2. Using
and/or
buttons set the
programmed password.
Notes:
a) The factory default password for configuration
parameters is 30.
b) The parameter changes are protected by a time
out. If no key is pressed for more than 10 sec-
onds the instrument automatically returns back
to the Standard display, the new value of the last
selected parameter will be lost and the parame-
ter modification procedure closed.
Sometimes can be useful to enter the parameter
configuration procedure with no timeout (e.g. for
the first time an instrument is configured). In
this case, use a password equal to the previ-
ously set password + 1000 digits (e.g. 1000 + 30
TC/mV
[default] = 1030).
Pt100
It is always possible to manually end the
PTC-NTC
parameter configuration procedure (see the
next paragraph).
c) During parameter modification the instrument
continues to perform the Alarms and timer func-
tions. In certain conditions, when a configura-
tion change can produce a bump to the process,
it is advisable to temporarily stop the alarm
functions during the programming procedure (its
alarms output will be Off).
A password equal to 2000 + the programmed
value (e.g. 2000 + 30 = 2030).
The alarms will restart automatically when the
configuration procedure will be manually closed
3. Push the
button
If the password is correct the display will show
OUT1
the acronym of the first parameter group
preceded by the symbol .
In other words the display will show
The instrument is in configuration mode.

3.2 How to exit the configuration mode

Push
button for more than 5 seconds. The instru-
ment will come back to the "standard display".
3.3 Keyboard functions during
parameters modification
A short pression allows to exit the current param-
Ext.
eter group and select a new parameter group.
gen.
A long pression allows to close the configura-
tion parameter procedure (the instrument re-
turns to the "standard display").
PTC-NTC
Pt100
When the display is showing a group, the key
GND
TC
allows to enter in the selected group.
When the display is showing a parameter, the
key allows you to store the value shown and go
SSR: 20mA/10VDC
to the next parameter within the same group.
Increases the value of the selected parameter.
Decreases the value of the selected parameter.
OUT2
Note: The group selection is cyclic as well as the
selection of the parameters in a group.
3.4 Factory reset - Default parameters
loading procedure
Sometimes, e.g. when you reconfigure an instrument
previously used for other works or from other people
or when you have made too many errors during con-
figuration and you decided to reconfigure the instru-
ment, it is possible to restore the factory configuration.
This action allows you to put the instrument in a de-
fined condition (in the same condition it was at the
first Power ON).
The default data are the typical values loaded in the
instrument prior to shipping from factory. To load the
factory default parameter set, proceed as follows:
1. Press the
button for more than 5 seconds;
2. The display will show alternately "PASS" and "0";
3. Using
and
4. Push
button;
5. The instrument will turn OFF all LEDs then it will
show "dFLt" messages and than it turn ON all
LEDs of the display for 2 seconds and than it will
restart as at the first power ON.
The procedure is complete (the default value of
each parameter is listed in the "Parameters Ta-
bles" paragraph).

4 - ERROR MESSAGES

4.1 Out of Range Signals

The display shows the OVER-RANGE and UNDER-
RANGE conditions with the following indications:
Over-range
The sensor break will be signalled as an out of range:
Note: When an over-range or an under-range is
detected, the alarms operate as in presence of
the maximum or the minimum measurable
value respectively.
WARNING!
Whenever a failure or a malfunction of the device may cause dangerous situations for persons,
things or animals, please remember that the plant must be equipped with additional safety de-
vices which will guarantee safety.
]

InP Group (parameters relative to the inputs)

no. Parameter
Parameter available by
1
HcFG
serial link nIt shows the
current hardware
Sensor selection (according to the hw)
TC, Pt100 input
2
SEnS
TC, PTC, NTC input
Current input
Voltage input
3
dP
Decimal figures
4
SSc
Initial scale readout
5
FSc
Final scale readout
Offset value (to shift the
6
0.Pot
zero readout)
7
unit
Engineering unit
Digital filter on the
8
FiL
measured value
9
diF1
Digital input 1 function
10
diF2
Digital input 2 function
.
To check the out of span Error condition, proceed as
follows:
1. Check the signal source and the connecting line.
2. Make sure that the input signal is in accordance
with the instrument configuration. Otherwise,
modify the input configuration (see section 4).
3. If no error is detected, send the instrument to
your supplier to be checked.

4.2 List of possible errors

ErEP- Possible problem of the instrument memory.
The message desappears automatically. If the error
continues, send the instrument to the supplier.
5 - GENERAL NOTES
5.1 Proper Use
Every possible use not described in the complete
manual (www.ascontecnologic.com) must be consid-
ered as a improper use.
This instrument is in compliance with EN 61010-1
"Safety requirements for electrical equipment for
measurement, control and laboratory use"; for this
reason it coud not be used as a safety equipment.
Ascon Tecnologic S.r.l. and its legal representa-
tives do not assume any responsibility for any
damage to people, things or animals deriving from
violation, wrong or improper use or in any case not
in compliance with the instrument's features.
5.2 Warranty and repairs
This product is under warranty against manufacturing
defects or faulty materials that are found within 12
months from delivery date.
The warranty is limited to repairs or to the replace-
buttons, set the value -481;
ment of the instrument.
The tampering of the instrument or an improper use of
the product will bring about the immediate withdrawal
of the warranty's effects.
In the event of a faulty instrument, either within the pe-
riod of warranty, or further to its expiry, please contact
our sales department to obtain authorisation for send-
ing the instrument to our company.
The faulty product must be shipped to Ascon Tecno-
logic with a detailed description of the faults found,
without any fees or charge for Ascon Tecnologic, ex-
cept in the event of alternative agreements.
Before supplying tension to the instrument, make sure
that it is perfectly dry.
Under-range
Description
Range
TC/RTD
TC/PTC
Current
Volt
J, crAL, S, r, t, ir.J, ir.cA, Pt1, 0... 50 (mV),
0... 60 (mV), 12... 60 (mV)
J, crAL, S, r, t, Ir.J, Ir.cA, Ptc, ntc, 0... 50 (mV),
0... 60 (mV), 12... 60 (mV)
0... 20 (mA), 4... 20 (mA)
0... 5(V), 1... 5(V), 0... 10(V), 2... 10(V), 0... 1 (V)
0... 3
From -1999 to FSC (E.U.)
From SSc to 9999 (E.U.)
From SSc to Fsc (E.U.)
°C or °F
From 0 (oFF) 20.0 (s)
oFF
= No function
AAC
= Alarm Reset
ASi
= Alarm acknowledge (ACK)
HoLd = Hold of the measured value
r.Pic
= Peaks reset
0.Pot = Start of the 0.Pot procedure
r.PoP = Start of the 0.Pot proc. and Peaks reset
t.rHr
= Timer Run/Hold/Reset [transition]
t.run
= Timer Run [transition]
t.rES
= Timer reset [transition]
t.rH
= Timer run/hold [Status]
uP.du = Digital inputs in parallel to
Vis.
Default
Promo.
According
Not
to the
displayed
Hardware
J
A-4
Ptc
4.20
0.10
A-5
0
A-6
-1999
A-7
9999
0 = °C
A-8
0 = °C
C-0
1.0
A-13
nonE
A-14
nonE
and
keys

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K V Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ascon tecnologic K V Series

  • Page 1 2. External components (like zener barriers, etc.) 4 - ERROR MESSAGES without any fees or charge for Ascon Tecnologic, ex- connected between sensor and input terminals cept in the event of alternative agreements.
  • Page 2 Out Group (parameters relative to the outputs) AL4 Group (parameters relative to AL4 - alarm 4) Vis. Vis. no. Parameter Description Range Default no. Parameter Description Range Default Promo. Promo. nonE = Output not used. AL4t Alarm 4 type Same range as [23] AL1t - Alarm 1 type LoAb = Alarm output Alarm 4 function...

This manual is also suitable for:

K3 v seriesK4 v seriesK85v seriesK31v seriesK38v series

Table of Contents