Galvin Engineering Clinimix CP-BS 100.90.70.20 Installation Manuallines

Thermostatic cartridge assembly for progressive mixer (lead safe-brass spline)

Advertisement

Quick Links

Product Installation Guidelines
®
Clinimix
CP-BS Thermostatic Cartridge Assembly for Progressive
Mixer (Lead Safe-Brass Spline)
PRODUCT CODES
-
100.90.70.20
SPECIFICATIONS
The cartridge assembly is made of Lead Safe* DR Brass
* As 'lead free' is not currently defined by low in Australia and New Zealand, we have based our definition of Lead Safe™ on the requirements of
s1417 of the USA's Safe Drinking Water Act (SDWA) and the relevant US standards NSF61 / NSF372. The SDWA defines 'lead free' as "not more
than a weighted average of 0.25% lead when used with respect to the wetted surface of pipes, pipe fittings, plumbing fittings and fixtures".
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Construction
Finish
NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without
notice.
DIMENSIONS
© Galvin Engineering Pty Ltd
Version 1, 11 January 2022, Page 1 of 5
Version 1, 11 January 2022, Page 1 of 5
N/A
N/A
Thermostatic Mixing Valve
Min
20
Max
500
Min
5
Max
85
N/A
DZR Brass
DZR Brass

Advertisement

loading

Summary of Contents for Galvin Engineering Clinimix CP-BS 100.90.70.20

  • Page 1 Thermostatic Mixing Valve Working Pressure Range (kPa) Working Temperature Range (°C) Nominal Flow Rate (LPM) Construction DZR Brass Finish DZR Brass NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without notice. DIMENSIONS © Galvin Engineering Pty Ltd...
  • Page 2: Installation

    Version 1, 11 January 2022, Page 2 of 5 INSTALLATION INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 3 (temperature setting ring) and the handle (section 6.1), the screw rotate the brass ring clockwise against the stop. and the top cap otherwise repeat to increase temperature or anti- from step 3 to 6. clockwise to decrease. © Galvin Engineering Pty Ltd...
  • Page 4 (temperature setting ring) and ring in the same rotate the brass ring clockwise position against step. 7. Re-test temperature to ensure to increase temperature or correct operation. anti-clockwise to decrease. Refit to spline in new position. © Galvin Engineering Pty Ltd...
  • Page 5: Troubleshooting

    WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.