CLEVA055
SPECIFICATIONS
-
CP Brass swing arm with stainless steel spring.
-
Supplied with stainless steel fasteners.
-
Finished in bright chrome plate for easy cleaning and added durability.
IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3662 and leave
our premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change
without notice.
TOOLS REQUIRED
Power drill
Spanner or adjustable crescent
© Galvin Engineering Pty Ltd
®
Hand Shower, Inverted RH T 700 X 1100 SS
Version 1, 2
½" BSP – Female
Handheld Shower
N/A
Min
150
Max
500
Min
5
Max
55
8.24
N/A
nd
June 2022, Page 1 of 4

Advertisement

loading

Summary of Contents for Galvin Engineering GalvinAssist CLEVA055

  • Page 1 CP Brass swing arm with stainless steel spring. Supplied with stainless steel fasteners. Finished in bright chrome plate for easy cleaning and added durability. IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3662 and leave our premises in good working order. TECHNICAL DATA ½”...
  • Page 2 June 2022, Page 2 of 4 Version 1, 2 June 2022, Page 2 of 4 INSTALLATION MOUNTING DETAILS − If the mounting holes do not already exist, mark out and drill the holes as shown in rough-in dimensions. Figure 1 © Galvin Engineering Pty Ltd...
  • Page 3 INSTALLATION Version 1, 2 June 2022, Page 3 of 4 INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 4 The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.