Please contact a service technician or your retailer. Purposes and Applications HID-2100 is intended to be used in healthcare institutions for general purpose as an assisting device for data access – patient information, records, media services, and so on. The product is designed for general or special use in the hospital environment.
Page 3
3. Repair of the device may also only be carried out by Warning! Because of the danger of electric shock, never remove the cover of a device while it is in operation or connected to a power outlet. HID-2100 Quick Reference Guide...
Page 4
Position the power cord so that people cannot step on it. Do not place anything over the power cord. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient over voltage. HID-2100 Quick Reference Guide...
Page 5
15. Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your country. Note! Environmental protection Follow national requirements to dispose of unit. Warning! Do not modify this equipment without authorization of the manufacturer. HID-2100 Quick Reference Guide...
Page 6
(if any) or even worse burn the equipment. 17. The product is not used in Category AP or Category APG in an anesthetic gas environment. HID-2100 Quick Reference Guide...
Page 7
HID-2100 User Manual Explanation of Graphical Symbols Warning: dangerous voltage Caution Note ISO 7000-1641: Follow operating instructions or Consult instructions for use. Direct current. Equipotential Stand-by US Conformance Follow the national requirements for disposal of equipment. HID-2100 Quick Reference Guide...
Page 8
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from the one the receiver is HID-2100 Quick Reference Guide...
Page 9
Selection of other channels is not possible. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Shielded interface cables must be used in order to comply with emission limits. HID-2100 Quick Reference Guide...
Page 10
Follow national requirements to dispose of unit. Manufacturer Avalue Technology Inc. 7F, No.87, Lide St., Zhonghe District, New Taipei City, 235, Taiwan 7F, No.95, Lide St., Zhonghe District, New Taipei City, 235, Taiwan TEL: +886-2-8226-2345 FAX: +886-2-8226-2777 Web: www.avalue.com.tw Information: sales@avalue.com.tw HID-2100 Quick Reference Guide...
HID-2100 User Manual CONTENT 1. HID-2100 Multi Touch Monitor Features ..........12 1.1 Packing List ..................12 1.2 Specifications ..................13 1.3 Front view ..................17 1.4 Rear & Bottom view ................18 1.5 System Dimensions ................19 2. Setting Up HID-2100 Multi Touch Monitor..........20 2.1 VESA Mounting ................
HID-2100 User Manual 1. HID-2100 Multi Touch Monitor Features ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ In this chapter, you will get to know all features of our HID-2100 Multi Touch Monitor. 1.1 Packing List 1 x HID-2100 Touch Monitor 1 x power adapter ...
Touch Interface Surface Anti-glare (Optional) Treatment Touch Disable Touch Disable Feature On-Screen Display OSD Buttons on right bottom side of touchscreen. Button On Screen Accessible through switches along the bottom: Display Controls: Menu, Up, Down, Select HID-2100 Quick Reference Guide...
Page 14
White VESA 4-hole 75mm/ 100mm mounting interface on rear Mounting Optional Wall Mount Kit (75mm or 100mm VESA) Options Optional Desk Stand (75mm or 100mm VESA) Warranty 2 Years (Standard) Reliability Certification CE FCC Class B HID-2100 Quick Reference Guide...
Page 15
Test Fh : Vibration boardband random Test 1 Test PSD : 0.026G²/Hz , 2.16 Grms 2 Test frequency : 5~500 Hz 3 Test axis : X,Y and Z axis 4 Test time : 30 minutes each axis HID-2100 Quick Reference Guide...
Page 16
3 Package weight : 4 Test drawing Operating 0°C ~ 40°C (32°F ~ 104°F) Temperature Operating 40°C @ 95% Relative Humidity, Non-condensing Humidity Storage -10°C ~ 60°C (14°F ~ 140°F) Temperature Note: Specifications are subject to change without notice. HID-2100 Quick Reference Guide...
USB (FOR TOUCH FUNCTION): USB Type B 2.0 port USB: Dual stack USB 2.0 Type A port x 2 Note! Equipotential terminal needs to be linked to the hospital ground/earth system before booting the system to protect both operator and system HID-2100 Quick Reference Guide...
HID-2100 User Manual 2. Setting Up HID-2100 Multi Touch Monitor ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ This chapter gives instructions on how to set up HID-2100 Multi Touch Monitor and how to connect different cables. 2.1 VESA Mounting 2.2 Cleaning and Disinfecting HID-2100 Quick Reference Guide...
Installation instructions follow: First attach the wall-mounting to the heat-sink of the HID-2100, securing it in place with four of the M4 x 6mm screws provided. Mount the on the wall, stand or other flat surface.
Page 22
HID-2100 User Manual Suggested Screw type for mounting Note: 4 pieces of M4 x 6mm screws (P/N: E1933050611R) Warning! Use suitable mounting apparatus to avoid risk of injury. HID-2100 Quick Reference Guide...
Follow below step Connecting the Ground pin 1. With system ready, find the equipotential terminal on the rear side of the HID-2100. An equipotential terminal is provided to optionally connect to a hospital ground/earth system. 2. Prepare grounding cable and the other terminal links to the hospital ground/ earth system.
Page 24
HID-2100 User Manual Please follow below steps to connect power cable to system. The HID-2100 could only be powered by a DC power adapter (EDAC Model no. EDAC EM11011M(18)). Be sure to always handle the power cords by holding the plug ends only.
HID-2100 User Manual 2.3 Cleaning and Disinfecting During normal use of HID-2100, the device may become dirty and should be regularly cleaned. Cleaning Instructions 1. Turn off the computer before starting clean up. This way, you can see any dirt on the screen; the brightness of the monitor may make you miss some areas.
HID-2100 User Manual 3. HID-2100 Installation Figure ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ 3.1 Desktop Stand installation Step1. Position VESA Mount on both sides, matching the holes on the system. Step2. Insert and fasten 4 screws on each side of the monitor to secure Mounting brackets.
CN6: Left speaker out connector CN7: Right speaker out connector CN8: Internal USB port (for Touch Panel use, with OSD menu power setup) connector CN9: Internal USB port CN11: I2C port connector (optional) CN12: DC12V output connector HID-2100 Quick Reference Guide...
VESA mount area. When using your HID-2100 systems, it is normal for the metal heatsink to get warm. The rear metal heatsink of the HID-2100 functions as a cooling surface that transfers heat from inside the computer to the cooler air outside.
Page 31
Handle your HID-2100 with care. It is made of metal, glass, and plastic and has sensitive electronic components inside. Don't use a damaged HID-2100, such as one with a cracked screen, as it may cause injury. Setup HID-2100 on a stable work surface.