Flowchart 1.2 Membrane Switches Not Functioning - Magnum fitness UB300 Maintenance Manual

Table of Contents

Advertisement

Flowchart 1.2 Membrane Switches not functioning

START HERE
Do any of the keys
function while the
board is lit up?
(beep noise)
no
Remove screws to
reveal back of
upper console
board.
Figure 2.1
Replace the
keypad that
yes
does NOT
function.
Unplug
B,C,D
figure 2.1 Does
the
START
key
work.
yes
Plug in
C
in figure
2.1. Press
START
then the LEFT
STOP/RESET.
Does this work?
yes
Plug in
D
in figure
2.1. Press
START
then the RIGHT
STOP/RESET.
Does this work?
yes
Plug in
A
in figure
2.1. Press
START
then the resistance
HIGHER and
LOWER keys.
Does this work?
D
A
Right Stop/Reset
Lower keypad
833-124
833-132
in
Replace lower
membrane
no
switch 833-132
Replace
STOP/RESET
no
with 833-124
Replace
STOP/RESET
no
with 833-124
Replace upper
keypad with
no
833-122
B
Upper keypad
833-122
C
Right Stop/Reset
833-124
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ub300h

Table of Contents