Changing Magnification or Filter

You may change the magnification and/or the filter AFTER the trace has been taken.
You can use the Options menu and select Change Magnification/Filter Settings or
you can click on the
Be careful not to increase the magnification to such an extent that the trace goes outside
of the chart area or the reference circle will not be valid. You can always return to the
original settings by pressing the Revert button.
Notes:
 If the trace went outside of the chart area (into the red area on the setup screen)
when you made the measurement then the results may not be valid. Reducing the
magnification without taking a new measurement will not correct for this error.
 You should not change the magnification when using a reference axis as datum.

Printing Results

There are two different formats for printing results.
deviations from the reference circle in degree increments, along with the normal
roundness results. The other is a printout of the roundness chart, similar to that seen on
the display. You can select the format from the File menu by clicking on either
Tabular Printout or Graphical Printout.
If you select Tabular Printout and then
select Print or Print Preview you will be
asked to enter a name (or number) that will
appear on the chart to associate the results
with a particular component. This can be
up to 12 digits. The table will be sent to the
printer or appear on screen as a preview.
You can choose to print from the preview
screen or, after viewing, you can close the
screen and make adjustments before
actually printing. If you are confident that
the printout will be as you wish then you
can print directly without choosing the
preview option.
If you select Graphical Printout and then
select Print or Print Preview you will be
presented with a dialog box which allows a
number of options to be selected.
The Basic Options tab allows the basic appearance to be
modified. Checking the Polar Grid allows the background
grid of the roundness chart to be shown. The Reference
Circle and Peak and Valley Circles allow the user to
choose whether or not to display these extra circles on the
chart. If the Identifications box is not checked then the
Company Heading will be removed from the printout along
with
all
extra
Sample Name which appears with the results.