Page 1
SERVICE BULLETIN SB3090 Rev A 10/12 ® fusion 2.4 Model 3110-026 Central Control Fluid Management System ............Model 3110-028 Distributed Control System Dispense Keypad ..........Model 3110-029 Distributed Control System Dispense Keypad w/built-in ticket printer ... Thoroughly read and understand this manual before installing, operating or servicing this equipment.
The information in this manual has been carefully checked and is believed to be entirely reliable and consis- tent with the product described. However, no responsibility is assumed for inaccuracies, nor does Balcrank Corporation. assume any liability arising out of the application and use of the equipment described.
CCS Keypad Keys The Scroll key selects options on the active display. The Home key returns the display to the default screen. The Backspace key deletes one character to the left of the cursor each time it is pressed. The Enter key completes the current action then displays the next screen. The Space key adds a blank space to the right of the data just entered.
Default Screen: The default display screen shows the date/time and software version number. The default display screen alternates between the System screen and the Enter Pin Number screen. 01Jan2002 01:05 Version 1.0 US The Enter Pin No. (Personal Identification Number) screen is used by the operator to access the system to dispense fluid.
Dispense Order Process The following screens some of which are optional, comprise the process for initiating a job dispense. Job No Job No.: Enter the job or work order number: This may be alphanumeric and up to 16 digits. To access alpha characters, press and hold the appropriate key until the desired alpha character is displayed.
Mileage The optional screen for milage is displayed only if the setting for milage is set to YES in the Configuration Menu, by the supervisor. (Optional) Mileage: Enter the milage of the vehicle. This is a numeric field up to 10 digits. Enter Mileage -------- Active keys:...
Quantity Quantity: Enter the quantity to be dispensed. • Quantity may be from 0.0 to 99.9 and 100 to 999. • There can only be one digit after the decimal point. Enter Quantity ---- Active keys: Numeric keys, Action: Select the quantity to be dispensed and press ENTER to advance or press HOME to cancel the order and return to the main screen.
Meter Operation: Dispensing Fluid After entering the job at the keypad, approach the RF control handle and perform the following steps: 1. Press the RESET button on the RF control handle 2. Note the two flashing arrows on the lower right por- tion of the LCD, these indicate that the RF control handle is communicating with the keypad 3.
NOTE This page is only for keypads with a built-in ticket printer. Models 3110-026 & 3110-029 Dispense Order Transaction Ticket: After the completion of a dispense by the RF Meter, a ticket receipt is printed. TRANSACTION TICKET DD/MMM/YYYY HH:MI PRODUCT FLUID TYPE 1 QUANTITY 2.1 LTS...
ERROR MESSAGES The following are error messages that can be displayed by the keypad and the associated action that should occur to reset the system. “KEY HOSE INT A communications error occurred between the keypad and meter. RESET ON HOSE” ACTION: Press RESET on the meter.