Advertisement

Model 3110-026
Model 3110-028
Model 3110-029
Thoroughly read and understand this manual before
installing, operating or servicing this equipment.
......................................................
..................................................
Distributed Control System Dispense Keypad w/built-in ticket printer
...........
Central Control Fluid Management System
Distributed Control System Dispense Keypad
SERVICE BULLETIN SB3090
Rev A 10/12
fusion 2.4
OPERATORS GUIDE
®

Advertisement

Table of Contents
loading

Summary of Contents for Balcrank Fusion 2.4

  • Page 1 SERVICE BULLETIN SB3090 Rev A 10/12 ® fusion 2.4 Model 3110-026 Central Control Fluid Management System ............Model 3110-028 Distributed Control System Dispense Keypad ..........Model 3110-029 Distributed Control System Dispense Keypad w/built-in ticket printer ... Thoroughly read and understand this manual before installing, operating or servicing this equipment.
  • Page 2: Disclaimer

    The information in this manual has been carefully checked and is believed to be entirely reliable and consis- tent with the product described. However, no responsibility is assumed for inaccuracies, nor does Balcrank Corporation. assume any liability arising out of the application and use of the equipment described.
  • Page 3: Table Of Contents

    Table of Contents Disclaimer ......................2 Product Identification Information ..............2 Specifications and Certification................. 4 Keypad Description..................5 Default Screen ....................6 Enter Pin No....................6 Dispense Order Process ................. 7 Registration (optional)..................7 License Plate No (optional) ................7 Mileage (optional) ....................
  • Page 4: Specifications And Certification

    Specifications Power Requirements 120V AC 50/60 Hz RF Communications 2-way, 2.4…2.5 GHz Direct Sequence Spread Spectrum RF Network Self-healing Mesh Network Operating Temperature 14…140° F (–10…60° C) Certification • Contains FCC ID: S4GEM35XB • Contains IC: 8735A-EM35XB • FCC CERTIFIED, PART 15, SUB-PART C •...
  • Page 5: Keypad Description

    CCS Keypad Keys The Scroll key selects options on the active display. The Home key returns the display to the default screen. The Backspace key deletes one character to the left of the cursor each time it is pressed. The Enter key completes the current action then displays the next screen. The Space key adds a blank space to the right of the data just entered.
  • Page 6: Default Screen

    Default Screen: The default display screen shows the date/time and software version number. The default display screen alternates between the System screen and the Enter Pin Number screen. 01Jan2002 01:05 Version 1.0 US The Enter Pin No. (Personal Identification Number) screen is used by the operator to access the system to dispense fluid.
  • Page 7: Dispense Order Process

    Dispense Order Process The following screens some of which are optional, comprise the process for initiating a job dispense. Job No Job No.: Enter the job or work order number: This may be alphanumeric and up to 16 digits. To access alpha characters, press and hold the appropriate key until the desired alpha character is displayed.
  • Page 8: Mileage (Optional)

    Mileage The optional screen for milage is displayed only if the setting for milage is set to YES in the Configuration Menu, by the supervisor. (Optional) Mileage: Enter the milage of the vehicle. This is a numeric field up to 10 digits. Enter Mileage -------- Active keys:...
  • Page 9: Quantity

    Quantity Quantity: Enter the quantity to be dispensed. • Quantity may be from 0.0 to 99.9 and 100 to 999. • There can only be one digit after the decimal point. Enter Quantity ---- Active keys: Numeric keys, Action: Select the quantity to be dispensed and press ENTER to advance or press HOME to cancel the order and return to the main screen.
  • Page 10: Meter Operation

    Meter Operation: Dispensing Fluid After entering the job at the keypad, approach the RF control handle and perform the following steps: 1. Press the RESET button on the RF control handle 2. Note the two flashing arrows on the lower right por- tion of the LCD, these indicate that the RF control handle is communicating with the keypad 3.
  • Page 11: Dispense Transaction Ticket

    NOTE This page is only for keypads with a built-in ticket printer. Models 3110-026 & 3110-029 Dispense Order Transaction Ticket: After the completion of a dispense by the RF Meter, a ticket receipt is printed. TRANSACTION TICKET DD/MMM/YYYY HH:MI PRODUCT FLUID TYPE 1 QUANTITY 2.1 LTS...
  • Page 12: Error Messages

    ERROR MESSAGES The following are error messages that can be displayed by the keypad and the associated action that should occur to reset the system. “KEY HOSE INT A communications error occurred between the keypad and meter. RESET ON HOSE” ACTION: Press RESET on the meter.
  • Page 13 This page intentionally left blank...
  • Page 14 For Warranty Information Visit: www.balcrank.com Revision Log Balcrank Corporation ® Weaverville, NC 28787 New Release - 10/12 800-747-5300 800-763-0840 Fax www.balcrank.com SERVICE BULLETIN SB3090 Rev A 10/12...

This manual is also suitable for:

3110-0263110-0283110-029

Table of Contents