alkitronic X E Series Operating And Maintenance Manual

alkitronic X E Series Operating And Maintenance Manual

Electric torque multiplier

Advertisement

Quick Links

E (PG)
Operating and
maintenance manual
Electric torque multiplier
E Serie

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for alkitronic X E Series

  • Page 1 E (PG) Operating and maintenance manual Electric torque multiplier E Serie...
  • Page 2: Table Of Contents

    Operation and Maintenance Manual Foreword Content Table Page Reception Control and Packaging Congratulations on your purchase of an alkitronic® electric torque multiplier. This product sets the highest international General Description standards for quality and safety. To maintain these standards, Model Description please read and follow the information and instructions found in the operation and maintenance manual.
  • Page 3: A Reception Control And Packaging

    B 1 Model Description alkitronic® E, torque has ranges up to approx. 10,000 Nm (7,375 ft.lbs), 2 speeds (Power Gear/Run-Down Gear) and clockwise/anti-clockwise direction. The 360 degree rotating handle ensures comfortable and safe operation.
  • Page 4: Safety Instructions

    Intended use Before connecting the electrical power, ensure the indicated technical data on the tool type plate alkitronic® electric torque multipliers are designed to tighten as well as in the operation manual corresponds or loosen heavy duty bolt connections continuously. Do...
  • Page 5: Preparing For Bolting

    Preparing for bolting alkitronic® STACO • Place the alkitronic® torque multiplier on a flat surface. • If the DMA is secured with a safety screw, remove the safety screw completely (the position of the screw can vary dependent on type).
  • Page 6: Setting Torque Value

    Operation and Maintenance Manual Mechanic Operation 4.2 Setting torque value The torque setting on the alkitronic® torque multiplier must Tightening and loosening be effected by the thumbwheel (1) and the gear selector lever (3) according to the torque table (A).
  • Page 7: Working Steps

    • Connect the torque multiplier to the power supply. Serious damages and many accidents are caused • Place the alkitronic® torque multiplier with alkitronic® by poorly inspected tools. STACO/STABI completely on the bolt/nut.
  • Page 8: Storage In Original Packaging

    Taking out of operation torque multiplier extensively or even cause the equipment to shut down. Additionally in case of If the alkitronic® electric torque multiplier is to be damage, warranty claims are at risk. Consistent stored for a long time:...
  • Page 9: Appendix

    PG 2 / 150 PG 2 / 250 PG 2 / 350 PG 2 / 600 PG 2 / 800 PG 2 / 1000 alkitronic Models: Torque range (approx.) gear 2 * 370 - 580 540 - 915 600 - 1100...
  • Page 10 Operation and Maintenance Manual Notes...
  • Page 11 electric torque multiplier Notes...
  • Page 12 Spare part and repair service alki TECHNIK GmbH Development, Production and Distribution of Bolting Systems Unterlettenweg 4 – 85051 Ingolstadt/Germany – fon +49 841 97499-0 – fax +49 841 97499-90 info@alkitronic.com – www.alkitronic.com EXTRACT FROM OUR PRODUCT RANGE THE ELECTRICS THE PNEUMATICS...