Digi MIL-240FXC Installation Manual

100base-fx redundant port selector

Advertisement

Quick Links

MIL-240FXT/MIL-240FXC
SC Connector
Main Port
Redundant Port Selector
Selector
Primary Port
SC Connector
This guide includes the following information:
"About this manual" on page 2
"Introduction" on page 2
"Features" on page 2
"Installation" on page 2
"Theory of Operation" on page 3
"Indicators" on page 3
"Specifications" on page 4
"Legal" on page 5
100BASE-FX
Redundant Port Selector
PS
5 V DC
1.5 A
MPSD
MIL•240FXC
100BASE-FX
PPSD
SC Connector
PWR
BPSD
Backup Port
SC Connector

Installation Guide

ST Connector
Main Port
MIL•240FXT
100BASE-FX
Redundant Port Selector
ST Connector
Selector
Primary Port
Backup Port
ST Connector
ST Connector
PS
5 V DC
1.5 A
MPSD
PPSD
PWR
BPSD
Doc #: 90000021 Rev. C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIL-240FXC and is the answer not in the manual?

Questions and answers

Summary of Contents for Digi MIL-240FXC

  • Page 1: Installation Guide

    MIL-240FXT/MIL-240FXC Redundant Port Selector SC Connector Main Port MIL•240FXC 100BASE-FX Redundant Port Selector SC Connector Selector Primary Port Backup Port SC Connector SC Connector Installation Guide This guide includes the following information: “About this manual” on page 2 “Introduction” on page 2 “Features”...
  • Page 2 Install Guide A b ou t th i s m a nua l This manual covers both the MIL-240FXT and the MIL-240FXC. The terms “MIL- 240FX,” “transceiver,” and “device” are used throughout this document to describe either transceiver. I ntrod uct i o n The MIL-240FXC/240FXT is a 100BASE-FX, fault-tolerant transceiver.
  • Page 3 Primary Port (BPSD may be on). When MPSD and BPSD illuminate at the same time, the node attached to the Main Port is connected to the node attached to the Backup Port (PPSD is off). Model: MIL-240FXC/MIL-240FXT Main Port 5 V DC 1.5 A...
  • Page 4 Op era t i n g Condi t i ons Table 1: Recommended Operation Conditions Operating Temperature Humidity: Non-condensing Signal Output Load Supply Voltage Ambient Operation Model: MIL-240FXC/MIL-240FXT ST Connector (rear view) (rear view) Figure 2. Connections Parameters Minimum +5° C 35 ohm 4.75 V...
  • Page 5 L eg al Regulat o r y A pprovals • FCC Class A • UL 1950 • CSA 22 No. 950 • EN60950 • – EN55022 Class B – EN50082-1 Canad ia n EM I No tice This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.