3.2.2 TCP_CLIENT pattern

1. Open Google browser, and enter 192.168.1.254 to log in to the webpage
configuration interface.
Network Setting: IP address 192.168.1.254, Device port: 502, Wok mode: TCP client,
set the Destination IP/DNS to the server IP address to be connected: 192.168.1.51 (IP
address of the local NIC), and remote port number: 6004.
Serial port device parameters: 19200bps, N81.The Serial Port test tool Serial Port
Utility is used to simulate Serial Port devices.
Multiple Host Config: Select the conversion protocol as None.
Click Submit when the Settings are completed.
Open the TCP debugging assistant, and it simulates THE TCP Server (local IP address
192.168.1.51, port number 6004), and wait for the protocol converter to be actively
connected.
Open the Serial Port Utility to simulate the underlying Serial Port device.
The following figure shows the screenshot of normal communication of data: