24.7.3 OSC Page

The OSC page has four independent settings for up to four MIDI remote controls via Open Sound
Control (OSC). This is a network based remote protocol that can be used for example by Apple's
iPad with the app TouchOSC or Lemur to wirelessly remote control TotalMix FX running on a Mac
or Windows computer.
Index
Select one of four settings pages and thus remote controls. Settings are remembered automati-
cally. To activate or deactivate any of the four remote controls check or uncheck 'In Use'.
TotalMix FX OSC Service
 IP. Shows the network address of the
computer running TotalMix FX (local
host). This address must be entered on
the remote side.
 Host Name. Local computer name.
 Port incoming. Must match the remote
entry 'Port outgoing'. Typical values are
7001 or 8000.
 Port outgoing. Must match the remote
entry 'Port incoming'. Typical values are
9001 or 9000.
Remote Control
 IP or Host name. Enter the IP or host
name of the remote control. Please note
that the IP number usually works better
than the host name.
Options
 Send Peak Level Data. Activates the
transmission of the peak level meter
data. Peak Hold activates the peak hold
function as set up for the TotalMix level
meters in the preferences.
 Lock Remote to submix. When acti-
vated the current remote control can only
modify the submix selected from the
drop-down list. This prevents havoc in
multi-remote monitoring environments.
 Number of faders per bank. Available choices are 8 (default), 12, 16, 24, 32 and 48. Note
that when working in underperforming networks, especially wireless, a higher number of fad-
ers might not work as smooth as expected.