Installation & Maintenance Manual
IMPORTANT:
READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS WIRED REMOTE CONTROL
SWITCH. KEEP THIS MANUAL FOR FUTURE REFERENCE.
No part of this manual may be reproduced without written permission.
Signal words (DANGER, WARNING, and CAUTION) are used to identify levels of hazard seriousness.
identifying hazard levels are provided below with their respective signal words.
DANGER
: Immediate hazards which WILL result in severe personal injury or death.
: Hazards or unsafe practices which COULD result in severe personal injury or death.
WARNING
: Hazards or unsafe practices which COULD result in minor personal injury or product or property
CAUTION
damage
NOTE: Useful information for operation and/or maintenance.
1. SAFETY SUMMARY
DANGER
DO NOT pour
into the remote control
WARNING
DO NOT perform installation
dealer of C&H
CAUTION
DO NOT install the indoor unit, outdoor unit, controller and cable at such places :
1. Where there is oil vapor and the oil is dispersed
2. Where the hot springs are near (in a sulfuric environment)
3.
4.
5.
DO NOT install the indoor unit, outdoor unit, controller and cable
from strong.
electromagnetic
radiators such as medical equipment. In case that the controller is installed in a place
there is electromagnetic
steel box and running the cable through the metal conduit tube.
Check the box
after checking.
2.
[2.1 Selection of Installation Place]
1)
Select a suitable place for handling and determine the installation place of the controller with the customer's acceptance. Do not install the controller at a place:
within the reach of children
[2.2 Before Installation]
1)
This packing contains the following parts.
Remote control Switch......1
Assembling screw M4*5/8in.(16mm)......2
Installation spot check specification......1
[2.3 Installation Procedures]
Insert the edge of the slotted screwdriver into the groove at the
1)
bottom of the holding bracket, push and turn the slotted screwdriver
and then remove the controller from the holding bracket.
2) Attach the controller to the holding bracket and connect the cable as follows.
A. In Case of Exposing Remote Control Cable
Fix the holding bracket
onto the wall with screws
(accessory)
del: SPWT-A01 )
(hereafter called "controller"). This product is equipped
and electrical
connection
ammable gas is detected
direct-radiation, shield the controller and cables
c
where the air from the air conditioner is directly discharged
Groove Part
Cable
1
Contact
9.84ft.(3m)
Groove Part for Removing Contronller
Approx. 6mm
Slotted Screw Driver
Attach the stopper to the
cable at the inside of the
draw-out hole.
Lead the cable with its
sheath peeled through
the groove.
Peel the insulation at
the end of the cable and
clamp the M3 solderless
of
distributor or
covering
the
.
Bottom View
Need help?
Do you have a question about the SPWT-A01 and is the answer not in the manual?
Questions and answers