  • Page 1 User manual for the JSGCT60 Coin Operated Timer Part Number 918-001-084 July 2018 Issue 1 (Version 60.4 )
  • Page 2: Table Of Contents

    Contents Introduction ......... . . Operational Features .
  • Page 3: Introduction

    Introduction Operational Features The JSGCT60 meter is a 60 amp coin or token operated electronic timer. It provides secure, reliable and affordable timing metering solutions for switching up to 60 amps. Standard features include credit save facility, resettable and non-resettable coin counter, dual or single coin operation and the time period may be set in minutes and seconds or hours and minutes.
  • Page 4: Installation

    (see Figure 2). Unplug the cover flying lead from the wall bracket and remove front cover. The JSGCT60 should be mounted on a smooth vertical wall making sure access to the side coin entry is not obstructed. Take care to mount the case level in both the vertical and horizontal axes;...
  • Page 5: Service Mode

    Figure 4 - Front Panel Programming credit The JSGCT60 may be programmed for either single coin mode or totalise mode. Totalise mode must be configured by the distributor to be enabled. In totalise mode the meter will display the amount of money required and intermittently show ‘FEE’.
  • Page 6 NOTE In totalise mode single coin mode is invalidated and settings St01 and St02 are unused. Option settings Three option settings are available in the JSGCT60; Pre-start, Pre-end and Maximum Credit. St.05 Pre-start Value Pre-start runs prior to the session time allowing the customer time to prepare before the session starts.
  • Page 7: Audit Functions

    JSGCT60 Installation and Operating Instructions St.08 Maximum credit value The ‘Maximum Credit’ feature prevents credit being accumulated above a pre-set time limit. Entering the required time limit in setting St.08 enables this feature. The value is entered in hours and minutes or minutes and seconds depending on configuration of the meter.
  • Page 8: Operating Instructions

    JSGCT60 Installation and Operating Instructions Operating Instructions To Operate Meter Insert coin/token. The display will briefly show ‘Coin’. The display will then show the remaining credit. If the credit is greater than one hour it will be displayed in hours &...
  • Page 9: Specifications

    100 coins of 23mm diameter x 2.5mm thick Service Information The JSGCT60 meter has been designed to provide reliable long-term use for a variety of timing applications. No regular servicing is required, apart from emptying of the cash box. Repairs...