C C o o n n t t e e n n t t s s 1 About This Manual ..................1 1.1 Preface ......................1 1.2 Target Group....................1 1.3 Manual Description ..................1 1.4 Symbol Explanation..................1 1.5 Expression Explanation ................1 2 System Introduction ...................
Page 4
7 Management ....................16 7.1 Device Operation ..................16 7.2 Device Import..................... 17 8 Settings ......................19 8.1 Time Settings ..................... 19 8.2 Serial Port Settings ..................20 8.3 Network Settings..................20 8.4 DI Settings ....................21 8.5 DO Settings....................22 8.6 ADC Settings....................
It will be referred to as "UMCG" for short hereinafter unless otherwise specified. With continuous software update, the interface and functions of the software you are using may differ from the example pictures provided in this manual.
System Introduction 2.1 Brief Introduction UMCG is a data collection and protocol conversion device that can collect data from inverters, combiner boxes and other equipment in PV systems. Users can view the collected information by accessing the server through PC.
I I n n t t r r o o d d u u c c t t i i o o n n The UMCG supports 8-way RS485 terminal connection to equipment such as box transformer measurement and control equipment, electricity meter, PV combiner box and environmental monitor.
UMCG. step 2 Use a wire stripper to strip the protective layer and shielded layer of the cable to expose the copper core of the wire. step 3 Connect the DI cable to either the UMCG's“DI1~DI21”port: Connect 24V cable to“DI24V”port.
3.4 DO Output Dry Contact Wiring I I n n t t r r o o d d u u c c t t i i o o n n The UMCG supports 6-way output dry contact connection to the transformer or switchgear signal node.
User Manual 3 Introduction to Ports step 3 Connect cables outing from NO, NC and COMs to the corresponding ports of the UMCG. - - - - E E n n d d 3.5 PT100 Port Wiring I I n n t t r r o o d d u u c c t t i i o o n n The UMCG has two PT100 sampling ports, which are used for transformer oil temperature sampling and copper busbar temperature sampling respectively.
1 Lead the external (0~5Vdc, 4~20mA) analog signal cable to the wiring area of the UMCG. step 2 Strip the insulation layer of the cable to expose the copper core. step 3 Connect the 1st analog input signal line to the UMCG“V1A+, VA1–”; Connect the 2nd analog input signal line to the UMCG's“V2A+, VA2–”ports.
I I n n t t r r o o d d u u c c t t i i o o n n The 24Vdc power port of the UMCG has been connected to the DC side of the inverter and supplies DC power for it.
192.168.0.X, modify the IP address of NET1 to be on another network segment first. 4.2 Preparation before Login Connect PC to NET1 of the UMCG by using a network cable. (N N o o t t i i c c e e : Do not enable • the DHCP function of NET1.) Set the IP address of the PC to be on the same network segment as that of the •...
Page 15
User Manual 4 Login step 2 Select the desired language, enter username and password, fill in verification code, and click "Login". U U s s e e r r R R o o l l e e U U s s e e r r n n a a m m e e P P a a s s s s w w o o r r d d adamg1 O&M user...
Interface Description 5.1 Homepage I I t t e e m m N N a a m m e e Software name Navigation bar Submenu Display area Login user Exit button 5.2 WEB Menus N N a a v v i i g g a a t t i i o o n n B B a a r r / / M M e e n n u u S S u u b b m m e e n n u u T T h h i i r r d d - - L L e e v v e e l l M M e e n n u u Data display...
Page 17
User Manual 5 Interface Description N N a a v v i i g g a a t t i i o o n n B B a a r r / / M M e e n n u u S S u u b b m m e e n n u u T T h h i i r r d d - - L L e e v v e e l l M M e e n n u u 61850 settings...
Set parameters of devices under the management of the UMCG, such as running • parameters and protection parameters. List of devices managed by the UMCG is displayed on the left "Overview" column. 6.1 View Real-Time Data Click "Monitoring" -> "Data display" to enter the corresponding interface.
User Manual 6 Monitoring step 2 Select a to-be-queried parameter. step 3 Click "Query" to read the parameter setpoint of the current device. - - - - E E n n d d If the parameter value is beyond the setting range or the device does not support parameter query, the value will be turn red.
M M o o d d i i f f y y D D e e v v i i c c e e This function is used to modify information of devices connected to the UMCG, such as device name and device address. Specifically, proceed as follows:...
P P r r o o c c e e d d u u r r e e On this interface, you can import devices connected to the UMCG. step 1 Click "Management" -> "Device import", to enter the corresponding interface.
Page 22
7 Management User Manual step 2 Enter the device model. Ensure that the device model filled in is consistent with the configuration file name. step 3 Click "Browse" to select to-be-imported files. step 4 Click "Import" to finish the operation. - - - - E E n n d d...
F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n This function is used to set serial port parameters of the UMCG, for example, COM port information, including function of the port, baud rate, check bit, data bit, and stop bit.
F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n The UMCG is equipped with DI ports. On the "DI settings" interface, you can set the status of each DI port.
F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n The UMCG is equipped with DO ports. On the "DO settings" interface, you can set the status of each DO port.
– If the UMCG has been successfully connected to the server, the icon on the right will be – If the UMCG has failed to be connected to the server, the icon on the right will be Untick "Enable VPN" to disable the VPN function.
User Manual - - - - E E n n d d Remote IP on the interface is the address accessed by the UMCG. 8.9 Restart F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n...
User Manual 8 Settings 8.11 Template Management F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n This function provides convenience for saving, transferring and applying a configuration without the need to configure it every time.
8 Settings User Manual 8.14 61850 Settings S S e e t t t t i i n n g g M M e e t t h h o o d d step 1 Click "Settings" -> "61850 settings" to enter the corresponding interface. step 2 Enter the original model name and new model name, and click "Save"...
"Sure". If the access IP is set to "0.0.0.0", any background devices with valid IP address can access the UMCG; and if the access IP is set to a specific address, only the corresponding device can access the UMCG.
Click "Protocol" -> "Cloud service settings", to enter the corresponding interface. Tick "Enable cloud service settings" if device information collected by the UMCG needs to be uploaded to iSolarCloud; and if otherwise, you do not have to tick the option.
Page 33
Telesignalling packet does not contain time tag. COS enabling * Enable it as you need. In forwarding IEC104 protocol, the UMCG device UMCG ranks first ranks first. If "SOE enabling" and "COS enabling" are not ticked, the UMCG will not forward telesignalling packets.
Page 34
9 Protocol Settings User Manual table 9-2 NET2 port settings C C o o n n n n e e c c t t i i o o n n Q Q u u a a n n t t i i t t y y N N o o .
F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n On this interface, you can upgrade devices connected to UMCG, for example, the inverter.
All rights reserved including the pictures, markings and symbols used. Any reproduction or disclosure, even partially, of the contents of this manual is strictly forbidden without prior written authorization of Sungrow. Should you have any technical question about this software, please contact us.
Page 37
Sungrow Power Korea Limited Tokyo Seoul + 81 3 6262 9917 +827077191889 japanservice@jp.sungrowpower.com service@kr.sungrowpower.com Malaysia Philippines Sungrow SEA Sungrow Power Supply Co., Ltd Selangor Darul Ehsan Mandaluyong City +6019897 3360 +639173022769 service@my.sungrowpower.com service@ph.sungrowpower.com Thailand Spain SungrowThailand Co., Ltd. Sungrow Ibérica S.L.U.