Intelligent communication gateway
Hide thumbs Also See for UMCG:

Advertisement

Quick Links

U U M M C C G G I I n n t t e e l l l l i i g g e e n n t t C C o o m m m m u u n n i i c c a a t t i i o o n n
G G a a t t e e w w a a y y U U s s e e r r M M a a n n u u a a l l U U M M C C G G - -
U U E E N N - - V V e e r r 1 1 4 4 - - 2 2 0 0 2 2 1 1 0 0 4 4
UMCG-UEN-Ver14-202104
UMCG
I I n n t t e e l l l l i i g g e e n n t t C C o o m m m m u u n n i i c c a a t t i i o o n n G G a a t t e e w w a a y y
U U s s e e r r M M a a n n u u a a l l

Advertisement

Table of Contents
loading

Summary of Contents for Sungrow UMCG

  • Page 1 G G a a t t e e w w a a y y U U s s e e r r M M a a n n u u a a l l U U M M C C G G - - U U E E N N - - V V e e r r 1 1 4 4 - - 2 2 0 0 2 2 1 1 0 0 4 4 UMCG-UEN-Ver14-202104 UMCG...
  • Page 3: Table Of Contents

    C C o o n n t t e e n n t t s s 1 About This Manual ..................1 1.1 Preface ......................1 1.2 Target Group....................1 1.3 Manual Description ..................1 1.4 Symbol Explanation..................1 1.5 Expression Explanation ................1 2 System Introduction ...................
  • Page 4 6.1 Checking the Basic Information ..............14 6.2 Checking the Real-time State ..............14 7 Device Monitoring ..................15 8 Device Maintenance ................. 16 8.1 Device List ....................16 8.2 Firmware Update ..................16 8.3 Fault Recorder ................... 17 9 History Data ....................
  • Page 5: About This Manual

    It will be referred to as "UMCG" for short hereinafter unless otherwise specified. With continuous software update, the interface and functions of the software you are using may differ from the example pictures provided in this manual.
  • Page 6: System Introduction

    System Introduction 2.1 Brief Introduction UMCG is a data collection and protocol conversion device that can collect data from inverters, combiner boxes and other equipment in PV systems. Users can view the collected information by accessing the server through PC.
  • Page 7: Introduction To Ports

    3.1 Ethernet Port Wiring I I n n t t r r o o d d u u c c t t i i o o n n The UMCG offers two Ethernet ports. P P o o r r t t...
  • Page 8: Rs485 Port Wiring

    I I n n t t r r o o d d u u c c t t i i o o n n The UMCG supports 8-way RS485 terminal connection to equipment such as box transformer measurement and control equipment, electricity meter, PV combiner box and environmental monitor.
  • Page 9: Di Input Dry Contact Wiring

    UMCG. step 2 Use a wire stripper to strip the protective layer and shielded layer of the cable to expose the copper core of the wire. step 3 Connect the DI cable to either the UMCG's“DI1~DI21”port: Connect 24V cable to“DI24V”port.
  • Page 10: Do Output Dry Contact Wiring

    3.4 DO Output Dry Contact Wiring I I n n t t r r o o d d u u c c t t i i o o n n The UMCG supports 6-way output dry contact connection to the transformer or switchgear signal node.
  • Page 11: Pt100 Port Wiring

    User Manual 3 Introduction to Ports step 3 Connect cables outing from NO, NC and COMs to the corresponding ports of the UMCG. - - - - E E n n d d 3.5 PT100 Port Wiring I I n n t t r r o o d d u u c c t t i i o o n n The UMCG has two PT100 sampling ports, which are used for transformer oil temperature sampling and copper busbar temperature sampling respectively.
  • Page 12: Analog Port Wiring

    1 Lead the external (0~5Vdc, 4~20mA) analog signal cable to the wiring area of the UMCG. step 2 Strip the insulation layer of the cable to expose the copper core. step 3 Connect the 1st analog input signal line to the UMCG“V1A+, VA1–”; Connect the 2nd analog input signal line to the UMCG's“V2A+, VA2–”ports.
  • Page 13: 24Vdc Power Port Wiring

    I I n n t t r r o o d d u u c c t t i i o o n n The 24Vdc power port of the UMCG has been connected to the DC side of the inverter and supplies DC power for it.
  • Page 14: Login

    192.168.0.X, modify the IP address of NET1 to be on another network segment first. 4.1.2 Preparation before Login Connect PC to NET1 of the UMCG by using a network cable. (N N o o t t i i c c e e : Do not enable • the DHCP function of NET1.) Set the IP address of the PC to be on the same network segment as that of the •...
  • Page 15: Modify The Password

    User Manual 4 Login 4.3 Modify the Password Click , and select M M o o d d i i f f y y P P a a s s s s w w o o r r d d , enter the orginnal password and new password, click [Save].
  • Page 16: Interface Description

    Interface Description 5.1 Homepage I I t t e e m m D D e e s s c c r r i i p p t t i i o o n n Page and menu selection bar Information icon bar : Connection state of ETH1 port : Connection state of ETH2 port : Cloud service...
  • Page 17 User Manual 5 Interface Description N N a a v v i i g g a a t t i i o o n n B B a a r r / / M M e e n n u u S S u u b b m m e e n n u u T T h h i i r r d d - - L L e e v v e e l l M M e e n n u u Measuring point log...
  • Page 18: Overview

    Overview 6.1 Checking the Basic Information F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n In this interface, you can view the current power generation, real-time power, the number of online devices, etc., view the operating data and cycle (day, month, year, total) power generation curve.
  • Page 19: Device Monitoring

    Device Monitoring F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n View the real-time operating information of the selected device and the corresponding node status.
  • Page 20: Device Maintenance

    P P r r e e r r e e q q u u i i s s i i t t e e The device model and configuration file have been obtained through Sungrow Power Supply Co., Ltd.
  • Page 21: Fault Recorder

    F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n When the fault occurs, you can use this interface to locate the fault and find the cause of the fault. The operations involved in this interface are only performed by SUNGROW.
  • Page 22: History Data

    History Data 9.1 Operation Log F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n In this interface, you can view the operation log, such as login, logout, system restart and other operations and the corresponding time, which is convenient for later traceability.
  • Page 23: Measuring Point Log

    User Manual 9 History Data step 3 Click to export the log of parameter settings. - - - - E E n n d d 9.4 Measuring Point Log F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n In this interface, you can view the historical record information of the measuring point.
  • Page 24: System

    • during debugging. Clock Source NTP: It can synchronize the time of each device in the • network. Click this button, so that the time of the PC will be Use PC time synchronized with the time of the UMCG.
  • Page 25: Transfer Configuration

    1 Click“S S y y s s t t e e m m → → T T r r a a n n s s f f e e r r C C o o n n f f i i g g u u r r a a t t i i o o n n → → i i S S o o l l a a r r C C l l o o u u d d ”to enter the interface. step 2 Configure server parameters of iSolarCloud. If you need to upload the device information collected by the UMCG to iSolarCloud. You need to turn on the iSolarCloud switch. Otherwise, it does not need to be turned on.
  • Page 26: Modbus

    Upload when data changes. Upload with a Change The available range is 100~1000。 Uploading interval of telemetry packet When forwarding the IEC104 protocol, the UMCG ranks UMCG ranks first first. step 3 Click to configure advanced parameters. Click to export IEC104 setting information.
  • Page 27: Template Management

    F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n This function is used to set the serial port parameters of the UMCG, such as the COM port information.
  • Page 28: Ethernet

    F F u u n n c c t t i i o o n n D D e e s s c c r r i i p p t t i i o o n n This function is used for the network port parameters of the UMCG.
  • Page 29: About

    11 About In this interface, you can view the firmware version information of the UMCG, or scan the QR code on this page to create a power station.
  • Page 30: Appendix

    All rights reserved including the pictures, markings and symbols used. Any reproduction or disclosure, even partially, of the contents of this manual is strictly forbidden without prior written authorization of Sungrow. Should you have any technical question about this software, please contact us.
  • Page 31 Sungrow Power Korea Limited Tokyo Seoul + 81 3 6262 9917 +827077191889 japanservice@jp.sungrowpower.com service@kr.sungrowpower.com Malaysia Philippines Sungrow SEA Sungrow Power Supply Co., Ltd Selangor Darul Ehsan Mandaluyong City +6019897 3360 +639173022769 service@my.sungrowpower.com service@ph.sungrowpower.com Thailand Spain SungrowThailand Co., Ltd. Sungrow Ibérica S.L.U.