Advertisement

System Illustration
The ECW-GF-DP remote display panel is only compatible
with the ECW-GF controller.
ECW-GF-DP
W a
1
• Install the ECW-GF-DP in an indoor dry
location in a standard duplex junction box,
up to 328 ft (100 m) from the ECW-GF.
• Route the communication cable through
the 1/2-in entry.
• Communication cable type: 8 conductor
22 AWG shielded (Alpha 1298C or
equivalent)
2
• Connect the cable to the controller and
display in the following order:
Remote Display
J1
Red
1
+12V @100ma
Black
2
TX+
White
3
TX–
Green
4
Gnd
Orange
5
RX+
Blue
6
RX–
Brown
7
Gnd
Yellow
8
NC
THERMAL BUILDING SOLUTIONS
l l
Ambient thermister
EN-RaychemECWGFDP-IM-H58410      03/15
ECW-GF
Conduit
Heating cable
328 ft (100 m) max.
Terminate cable
Shield
shield at ECW-GF
controller end only
Power
ECW-GF
J5
1
T1
2
T2
3
SH
J6
Red
1 2 3 4 5 6 7 8
Black
White
Green
Orange
Blue
Brown
Yellow