10.2. Self-Diagnosis Function (DVD Section)
10.2.1. Self-Diagnosis Display
<Overview>
The details of failures detected in circuit or mechanism by the microcomputer will be
automatically displayed on the FIP as the result of self diagnosis.
<Setting>
The details of a failure applicable to an error code are displayed on the FIP.
<Display>
FIP display example: F 0 4
<List of Error Code>
Display
Type of error
U 11 Focus error
H 01 Tray loading
error
H 02 Spindle servo
error
F 03
Traverse servo
error
F 04
Tracking servo
error
F 05
Seek error
F 06
Power supply
error
10.2.2. Error Code Display
While pressing and holding down the PLAY and OPEN keys on the DVD layer, press the number
"0" in order to display the latest error code. (Automatically cancelled after five seconds.)
<Error Code Display>
Spindle servo, DSC, SP motor, CLV servo error
Power cannot be turned off due to communication error between panel
computer and system computer.