Instrument name
1. RF signal generator
2. Oscilloscope
3. Measurement computer
1. Select STEREO mode in the AUDIO Menu.
2. Apply following RF signal at Antenna input.
VIDEO : Flat field , 30% modulation
AUDIO : 300Hz ,30% modulation ,STEREO (LEFT only)
(70dB ± 5dB ,75
OPEN ,P/S 10dB)
Note:
After setting 30% modulation with P.L. SW and N.R. SW off, turn P.L. SW
and N.R. SW on.
3. Adjust "SEPAL" data (Low-level separation) until the amplitude.
4. Apply following RF signal at Antenna input.
VIDEO : Flat field , 30% modulation
AUDIO : 3kHz ,30% modulation ,STEREO (LEFT only)
(70dB ± 5dB, 75
OPEN, P/S 10dB)
Note:
After setting 30% modulation with P.L. SW and N.R. SW off, turn P.L. SW
and N.R. SW on.
5. Adjust "SEPAH" data (High-level separation) until the amplitude of the waveform on the
oscilloscope is minimum.
6. Repeat steps 2. to 5. until Low-level separation and High-level separation satisfy above-mentioned
conditions.
11.2. Sub contrast Adjustment (NTSC)
Connection
RF ANT. INPUT
TP216-GND
SCL2, SDA2, FA2
Procedure
28
Remarks
Remarks
The separation mustbe more
20 dB at 300Hz and 3kHz.