Adjustment; Mts Adjustment - Panasonic TH-42PA25U-P Service Manual

Progressive plasma television gp6du chassis
Hide thumbs Also See for TH-42PA25U-P:
Table of Contents

Advertisement

11 Adjustment

11.1. MTS Adjustment

11.1.1. Input level Adjustment
Instrument name
1. Filter jig
2. 2 RF signal generator
3. RMS voltage meter
4. Measurement computer
1. Apply following RF signal at Antenna input.
VIDEO : Flat field , 30% modulation
AUDIO : 300Hz ,100% modulation ,monaural
(70dB ± 5dB, 75 9 OPEN, P/S 10dB)
Note:
Make sure 75us PRE-EMPHASIS is off.
2. Adjust "MTSIN" data (Input level) until the RMS voltage meter indicates 106mVrms ±
6mVrms.
11.1.2. STERO Sep. Adjustment
Instrument name
1. RF signal generator
2. Oscilloscope
3. Measurement computer
1. Select STEREO mode in the AUDIO Menu.
2. Apply following RF signal at Antenna input.
VIDEO : Flat field , 30% modulation
AUDIO : 300Hz ,30% modulation ,STEREO (LEFT only)
(70dB ± 5dB ,759 OPEN ,P/S 10dB)
Note:
After setting 30% modulation with P.L. SW and N.R. SW off, turn P.L. SW and N.R.
SW on.
3. Adjust "SEPAL" data (Low-level separation) until the amplitude.
4. Apply following RF signal at Antenna input.
VIDEO : Flat field , 30% modulation
AUDIO : 3kHz ,30% modulation ,STEREO (LEFT only)
(70dB ± 5dB, 759 OPEN, P/S 10dB)
Note:
After setting 30% modulation with P.L. SW and N.R. SW off, turn P.L. SW and N.R.
SW on.
5. Adjust "SEPAH" data (High-level separation) until the amplitude of the waveform on the
oscilloscope is minimum.
6. Repeat steps 2. to 5. until Low-level separation and High-level separation satisfy above-
mentioned conditions.
Connection
TP215 (L out)
RF ANT. INPUT
Filter jig
SCL2, SDA2, FA2
Procedure
Connection
RF ANT. INPUT
TP216-GND
SCL2, SDA2, FA2
Procedure
25
Remarks
Remarks
Remarks
Remarks
The separation must be more than 20 dB at
300Hz and 3kHz.
TH-42PA20U-P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-42pa25u-aTh-42pa20u-p

Table of Contents