Download Print this page
Galvin Engineering GalvinCare CP-BS Product Installation Manualline

Galvin Engineering GalvinCare CP-BS Product Installation Manualline

Lead safe mental health anti-ligature ceiling mounted shower rose stainless steel plate

Advertisement

Quick Links

Product Installation Guidelines
®
GalvinCare
CP-BS Lead Safe Mental Health Anti-Ligature Ceiling
Mounted Shower Rose Stainless Steel Plate
PRODUCT CODES:
- 121.70.10.00
SPECIFICATIONS
®
The GalvinCare
Mental Health Ceiling Mounted Shower Rose provides anti-vandalism and anti-ligature
features.
Used extensively in high risk, high security applications such as prisons, correctional facilities, and
detention centres.
Constructed from heavy duty components and comes complete with special tamper resistant screws.
For use with high pressure plumbing systems between 150 & 500kPa.
Special consideration may be required when used with low water pressure systems and components.
Chrome plate finish for easy cleaning and added durability
Lead Safe™ brass construction*
IMPORTANT: All GalvinCare
AS/NZS 3662 and leave our premises in good working order.
*As 'lead free' is not currently defined by law in Australia and New Zealand, we have based our definition of Lead Safe™ on the requirements of s1417 of the USA's Safe Drinking Water Act (SDWA)
and the relevant US standards NSF61 / NSF372. The SDWA defines 'lead free' as "not more than a weighted average of 0.25% lead when used with respect to the wetted surface of pipes, pipe
fittings, plumbing fittings and fixtures".
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
© Galvin Engineering Pty Ltd
®
vandal resistant ceiling mounted shower roses are tested in accordance with
Version 1, 17 November 2022, Page 1 of 4
½" BSP - Male
Shower Rose
N/A
Min
150
Max
500
Min
5
Max
70
6.6
Chrome

Advertisement

loading

Summary of Contents for Galvin Engineering GalvinCare CP-BS

  • Page 1 ½” BSP - Male Inlet Outlet Shower Rose Headwork Working Pressure Range (kPa) Working Temperature Range (°C) Nominal Flow Rate (LPM) Finish Chrome NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice. © Galvin Engineering Pty Ltd...
  • Page 2 2. Connect the water line − Fit the shower assembly into cealing cut out − Connect water supply to the inlet. spud hole. − Use suitable sealant to prevent leaks. − Secure shower assembly with suitable fastenings as shown. © Galvin Engineering Pty Ltd...
  • Page 3 Turn on water supply, inspect the shower and check for any leaks . ® Note: Never operate without a flow restrictor, as GalvinCare Vandal Resistant Shower Rose will deliver full mains pressure with unrestricted flow. © Galvin Engineering Pty Ltd...
  • Page 4 Apply more sealant WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.

This manual is also suitable for: