Summary of Contents for Melink PositiV

  • Page 1: Step

    Installation Manual Rev 1.5 Melink Corporation 5140 River Valley Road, Milford, OH 45150 513-965-7300 melinkcorp.com ...
  • Page 2: Table Of Contents

    PositiV® Installation Manual Table of Contents Step 1 Unboxing and Powering On ........................ Page 3 Step 2 Scouting ............................... Page 5 Step 3 Configuration ............................. Page 6 Step 4 Calibration ............................... Page 10 Step 5 Troubleshooting & FAQ........................Page 11...
  • Page 3: Unboxing And Powering On

    Unit Outdoor Power on the indoor PositiV® unit by pulling the clear tab from the top of the unit and tightening the screws on the back of the unit. Power on the outdoor PositiV® unit by first unscrewing the 5 screws on the unit’s back.
  • Page 4 PositiV® Installation Manual Once the screws are removed, pull the front cover from the outdoor unit to expose the inside circuitry. Note: The solar panel is connected to the circuitry. Pull with caution. Additionally, pulling the cover from the base can be difficult.
  • Page 5: Scouting

    PositiV® Installation Manual Step 2: Location Identification Identify a suitable installation location for the indoor unit. Key attributes:  Minimal airflow interference  Out of reach of occupants  Minimal impact from nearby  Sufficient ambient light (>200 Lux) equipment ...
  • Page 6: Configuration

    PositiV® Installation Manual Step 3: Configuration Download the “Melink PositiV®” app from the Google Play Store. With the indoor and outdoor units next to each other, press the Bluetooth button on the circuit board of the outdoor unit. Screw the cover onto the back of the outdoor unit.
  • Page 7 Note: The indoor unit label is found behind the backplate on the indoor unit. The PositiV® system may take up to a minute to be located on the app.
  • Page 8 Once the proper unit has been selected, you will be prompted to “Enter Pair Code.” Enter the BLE# found on the back of your outdoor PositiV® unit. You should now see that the selected device is connected. On your phone, select the connected device and choose “RSSI Test.”...
  • Page 9 PositiV® Installation Manual With both units, walk to the desired installation location of the outdoor unit. Mount the outdoor unit by either (a.) banding the unit to an exhaust vent using the provided pipe clamp, (b.) screwing the unit to an RTU / air handling equipment, or (c.) screwing the unit to concrete or masonry.
  • Page 10: Calibration

    Click “Pressure Calibration” on the Melink PositiV® app. Follow the steps as described on the Melink PositiV® app. After calibration has completed, clip the indoor unit to the backplate as shown. Hook Backplate (Please note the correct orientation of the PositiV® indoor unit in the image above.)
  • Page 11: Troubleshooting & Faq

    If required, identify new installation locations and reconfigure the devices. What do I do if my PositiV® system does not show up when I open the Melink PositiV® app? Verify that Bluetooth is enabled on your phone. Then, close and reopen the app. It may take up to a minute for the PositiV®...