IND-SFC Series Safety Information Read this user manual before using frequency converter. Keep this user manual near the frequency converter for reading at any time. Careful in transporting the frequency converter to avoid impact. Do not put the frequency converter on uneven or inclined surface.
Page 3
IND-SFC Series Product Features Frequency converter is suitable for use with resistive, capacitive, inductive and non-linear loads. Compatible with 50 Hz & 60 Hz input frequency. Adjustable single phase 0-300v AC, three phase 0-520v AC output voltage.
Page 4
IND-SFC Series ① ② ⑥ ③ ⑦ ⑧ ④ ⑤ R S T N G U V W N G Three Phase ① Operation Panel ② Input Air-switch ③ Output Air-switch ④ Input Terminals ⑤ Output Terminals ⑥ Low/High Voltage Switch (For 30kVA and Above) ⑦...
IND-SFC Series Wiring Precaution Whether the capacity of the frequency converter in accordance with your loads. Whether the frequency converter damaged during transportation, if so, do not connect it to power source. Shut down power before wiring, check the input voltage before installation.
IND-SFC Series Chapter VI. Operation Guide Proper operating procedures allow you to use the frequency converter more smoothly and avoid unnecessary troubles. 1. Make sure the POWER ON switch is on OFF position. 2. Make sure the switches, rotary buttons, displays are not loosen or damaged.
IND-SFC Series Chapter VII. Specification Single Phase Input, Single Phase Output Capacity 500VA 1kVA 2kVA 3kVA 5kVA 10kVA 15kVA 20kVA Voltage (Optional) 1 Phase 2 Wire: 110V/220V/230V/240 ± 10% Input Frequency 50Hz or 60Hz ± 5% 0-150V (Low Voltage range)
Page 12
IND-SFC Series Three Phase Input, Single Phase Output Capacity 10kVA 15kVA 20kVA 30kVA 45kVA 50kVA 60kVA 3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10% Voltage (Optional) 3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% Input 3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ±...
Page 13
IND-SFC Series Three Phase Input, Single Phase Output Capacity 75kVA 90kVA 100kVA 120kVA 150kVA 3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10% Voltage(Optional) 3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% Input 3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ±...
Page 14
IND-SFC Series Three Phase Input, Three Phase Output Capacity 3kVA 10kVA 15kVA 20kVA 30kVA 45kVA 60kVA 3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10% Voltage (Optional) 3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% Input 3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ±...
Page 15
IND-SFC Series Three Phase Input, Three Phase Output 75kVA 100kVA 120kVA 150kVA 200kVA 300kVA Capacity 3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V±10% Voltage (Optional) 3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% Input 3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ±...
IND-SFC Series Chapter VIII. Troubleshooting Please pay attention to internal high voltage components, only qualified electricians can maintain the frequency converter. Turn off the frequency converter before proceeding troubleshooting procedures if it's not necessary to do live troubleshooting. Phenomenon Inspection...
Operating temperature 0 - 40℃, humidity 0 - 90% (non-condensing). THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-877-348-9680 FOR FURTHER ASSISTANCE.