Page 1
・Any failures which may occur during this period and are attributable to our workmanship will be corrected free of charge. ・ KOFLOC shall bear no responsibility whatsoever for breakage or troubles of equipment resulting from neglect of the precautions presented in this manual or use of the pressure regulating valve in manners not described herein.
FJ400019I1 Created on 2021/12/20 ■Model 6600 ●Precautions for Handling 1) Installation ① Prior to connecting a pipe to the valve, be sure to flush the pipe. Dust/dirt, sand, scale, etc. remaining inside the pipe are causes of malfunction and failure.
Page 3
FJ400019I1 Created on 2021/12/20 ● Construction and External Dimensions Model 6600A 28 30.5 6600B 31 30.5 6600AL 28 33.5 OUT 10 6600BL 31 33.5 OUT 13 (mm) Cut out dimensions Body side M8×1 Body side M8×1 (2 places) Pressure regulating shaft Cap nut Bonnet bearing Panel mounting nut...
Page 4
FJ400019I1 Created on 2021/12/20 ■Model 6700 ●Precautions for Handling 1) Installation ① Prior to connecting a pipe to the valve, be sure to flush the pipe. Dust/dirt, sand, scale, etc. remaining inside the pipe are causes of malfunction and failure. ②...
Page 5
FJ400019I1 Created on 2021/12/20 ●Construction and External Dimensions Cut out dimensions The dimensions in parentheses are for Type B. Body Bonnet Pressure regulating shaft Bonnet bearing Bearing Pressure regulating spring Diaphragm caulking Diaphragm retaining plate M4 nut Diaphragm Stem Stem guide Nozzle Spring receiver Spring...
Page 6
FJ400019I1 Created on 2021/12/20 ●Troubleshooting (Model 6600) Trouble Cause Corrective Action The pressure 1. The direction of flow is 1. Check the direction of flow. cannot be reversed or the valve If it is reversed, reinstall the adjusted. installation is reversed.
Page 7
FJ400019I1 Created on 2021/12/20 ●Troubleshooting (Model 6700) Trouble Cause Corrective Action The pressure 1. The direction of flow is 1. Check the direction of flow. cannot be reversed or the valve If it is reversed, reinstall the adjusted. installation is reversed. valve correctly.
Page 8
KOFLOC specification. ② Scope of warranty If the KOFLOC product fails during the warranty period due to a cause attributable to KOFLOC, KOFLOC shall, at its option and expense, provide a replacement product or repair the failed product at the KOFLOC factory.
Need help?
Do you have a question about the 6600 and is the answer not in the manual?