Deekax DIVK-C121 DEMA Installation And User Manual page 4

Air exchange equipment
Table of Contents

Advertisement

TALTERI DIVK-C121 INSTALLATION
The air exchange unit is meant for warm inner facilities. Suitable installation spots are,
among others, office, dressing or household facilities and technical or warm storages. In case
the temperature of the installation location is lower than room temperature, the factory settings
of the appliance must be changed to obtain faultless functioning. The unit can not be installed
into cold outer premises or garages.
UPPER BASE DUCT
The channelling is usually mounted to the upper base thermal insulation.
The steam barrier puncture must be carefully sealed. While installing the unit to
channels, steel steam barrier plate, supplied as extra, will come handy. The steam
barrier plate is attached securely between the roof trusses, 10 mm smaller hole
must be cut into the gasket mat and channels are installed through the plate.
The steam barrier must be hermetically taped.
The unit can be attached right to the steam barrier plate with four M8 thread bars
at desired height. Note the measurements of the steam barrier plate during the
installation process.
The bolts and thread bars are purchased separately.
WALL ATTACHMENT
The wall mounting kit includes a ceiling mounting plate, a wall-mounting plate
and 15 mm thick insulation pieces. A wall-mounting plate is installed about 25 mm
below the roof surface.
The wall attachment plate will be fixed to the wall and then the unit lifted up
to the attachment plate, checked into perfectly horizontal position and then drill holes
for the metal screw through the mounting plate in to the bottom of the machine.
Roof moldings can be put around the machine.
KITCHEN EXTRACT DUCT
The channel output (5) in intended for extract channel of the cooker hood.
If the extract channel of the cooker hood is not in use, it must be closed.
If the cooker hood is connected to the kitchen extract duct ( heat recovery
bypassed),must close all the basic ventilation holes of the cooker hood
closing damper and in the kitchen it is needed a separate extract valve which
is connected to the extract air duct.
CONDENSATE
The condensate drain pipe is connected to the condensate connection on the machine
(3/8 "male thread). The condensate pipe can be made of copper pipe or rigid hose at
least 10 mm in internal diameter. To the water pipe is made about a 10 cm long water
trap and pipe are connected to the floor drain. The water pipe must not be connected
directly to the drain
4
WALLBRACKET
6kpl D=6,5mm
43
200
485
DOOR
TALTERI
177
Condensate connector
left(L)
200
43
157
172
177
Condensate connector
right(R)