Download Print this page
Penguin PSS Series Operating Instructions & Parts Manual

Penguin PSS Series Operating Instructions & Parts Manual

Vertical pump

Advertisement

Quick Links

P E N G U I N
P E N G U I N
O p e r a t i n g
Series PSS
VERTICAL PUMP
Models:
P-1/3S
P-1/2S
P-3/4S
P-1S
P-1 1/2S
P-2S
P-3S
P-5S
P-7 1/2S
P-10S
P-15S
Introduction
Penguin Series PSS vertical 316L stainless steel pumps have a liquid temperature range of -30 degrees F to 211
degrees F. Temperatures greater than 211 degrees F but less than 250 degrees F are acceptable for non-caustic,
non-hydrocarbon service.
Glass-filled Teflon (GFT) bushings and bearings are reinforced tetrafluoroethylene (TFE) products with the
following major advantages over unfilled, or virgin Teflon:
Increased ware and good abrasion resistance
Lower deformation under load
Less thermal expansion
Good lubricity
Brief dry-run capability
I n s t r u c t i o n s
Materials:
S - 316SS
&
S p a r e
P a r t s
P1/3 thru P2
M a n u a l
P3 thru P15

Advertisement

loading

Summary of Contents for Penguin PSS Series

  • Page 1 P1/3 thru P2 Introduction Penguin Series PSS vertical 316L stainless steel pumps have a liquid temperature range of -30 degrees F to 211 degrees F. Temperatures greater than 211 degrees F but less than 250 degrees F are acceptable for non-caustic, non-hydrocarbon service.
  • Page 2: Maintenance Instructions

    Maintenance Instructions Recommended installation for optimal performance and endurance. DISCHARGE PIPE GATE VALVE (NOTE 3) CHECK VALVE CONCENTRIC REDUCER MAX. LIQUID LEVEL MIN. LIQUID LEVEL Pump Installation Install the pump vertically in-tank with the pump immersed in the liquid approximately half way and the motor facing upward on the tank lip or structural beam on top of the tank.
  • Page 3 Maintenance Instructions • Keep friction head to a minimum by making the discharge line short and direct with as few fittings as possible. • The outlet piping should be supported as close to the pump as possible, using pipe hangers or pipe supports. •...
  • Page 4 Installation & Operation Instructions Motor Bearing Lubrication/Change-out • No motor bearing lubrication is required on motors that are furnished without plugs or grease fittings. These units are provided with permanently lubricated sealed bearings. Motors provided with grease fittings should be lubricated according to the motor manufacturer’s lubrication frequency schedule.
  • Page 5: Exploded View And Spare Parts List

    Exploded View and Spare Parts List I n s t a l l a t i o n & M a i n t e n a n c e...
  • Page 6: Spare Parts

    Spare Parts SERIES PS VERTICAL 316SS PUMP SPARE PARTS P-1/3S- P-1/2S- P-3/4S- P-1S- P11/2S- P-2S- DESCRIPTION MAT’L 3/4 X 1/2 1 X 3/4 1 X 3/4 1-1/2 X 1 1-1/2 X 1 1-1/2 X 1 SHAFT EXTENSION 316 PS-130-01 PS-130-01 PS-340-01 PS-130-01 PS-130-01...

This manual is also suitable for:

P-1/3sP-1/2sP-3/4sP-1sP-1 1/2sP-2s ... Show all