FRÄNKISCHE profi-air 180 Installation & Operating Instructions Manual

FRÄNKISCHE profi-air 180 Installation & Operating Instructions Manual

Flat condensate pump
Hide thumbs Also See for profi-air 180:

Advertisement

Quick Links

Installation / operating instructions
profi-air® 180 flat condensate pump
Building Technology
www.fraenkische.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the profi-air 180 and is the answer not in the manual?

Questions and answers

Summary of Contents for FRÄNKISCHE profi-air 180

  • Page 1 Installation / operating instructions profi-air® 180 flat condensate pump Building Technology www.fraenkische.com...
  • Page 2 Installation / operating instructions – profi-air 180 flat condensate pump...
  • Page 3: Table Of Contents

    Installation / operating instructions – profi-air 180 flat condensate pump Table of contents 1 General 1.1 Introduction 1.2 Safety 2 Intended use 3 Structure 4 Technical data 4.1 Device specifications 4.2 Capacity diagram 5 Installation 5.1 Parts overview of the entire condensate pump kit 5.2 Installation of the condensate pump...
  • Page 4: General

    1 General The profi-air condensate pump reliably discharges condensate from the profi-air 180 flat ventilation unit. It is required if a free condensate drain at a gradient of at least 2 % cannot be guaranteed. The delivery includes all necessary parts to connect the condensate pump to the ventilation unit.
  • Page 5: Intended Use

    2 Intended use The profi-air condensate pump has been designed for use with the profi-air 180 flat ventilation unit only and ensures the reliable discharge of condensate. The profi-air condensate pump is directly connected to the control of the profi-air 180 flat ventilation unit.
  • Page 6: Installation

    Please note that the condensate pump must always be installed on the fresh air / exhaust air side of the ventilation unit. This may vary depending on the operating mode (A or B) of the profi-air 180 flat ventilation unit.
  • Page 7: Parts Overview Of The Entire Condensate Pump Kit

    180 flat (high water level alarm signal) Inlet hose, Ø 12 mm x 210 mm (only required if the profi-air 180 flat ventilation unit has been installed vertically on the wall) Connection nipple for inlet hose (only required if the profi-air 180 flat ventilation unit has been installed vertically on the wall)
  • Page 8: Installation Of The Condensate Pump

    Installation / operating instructions – profi-air 180 flat condensate pump 5 Installation 5.2 Installation of the condensate pump max. 45° C...
  • Page 9 Installation / operating instructions – profi-air 180 flat condensate pump 5 Installation 5.2 Installation of the condensate pump purple grey brown blue Mode A Mode B RS485 RS485 Digital input Digital input 12 3 4 12 3 4 RS485 Digital input...
  • Page 10 Installation / operating instructions – profi-air 180 flat condensate pump 5 Installation 5.2 Installation of the condensate pump RS485 RS485 Digital input Digital input 12 3 4 12 3 4 RS48 RS485 Digital input 12 3 4 RS485 RS485 Digital input...
  • Page 11: Warranty

    Installation / operating instructions – profi-air 180 flat condensate pump 6 Warranty Deviating from the applicable GTCs, the manufacturer grants a warranty of 24 months from the time of completion of the installa- tion for the profi-air condensate pump. Warranty claims can only be asserted for material and/or construction defects occurring within the warranty period.
  • Page 12 FRÄNKISCHE Rohrwerke Gebr. Kirchner GmbH & Co. KG | Hellinger Str. 1 | 97486 Königsberg / Germany Phone +49 9525 88-2200 | Fax +49 9525 88-92200 | marketing@fraenkische.de | www.fraenkische.com EN.70149/3.02.21 | Subject to change without notice | Cat. No. 5000-1343-00 | 01/2018...