FRÄNKISCHE profi-air 180 Installation And Operating Instructions Manual

Flat condensate pump
Hide thumbs Also See for profi-air 180:

Advertisement

Quick Links

profi-air
180 flat condensate pump
®
Installation and operating instructions
DRAINAGE SYSTEMS
ELECTRICAL SYSTEMS
BUILDING TECHNOLOGY
INDUSTRIAL PRODUCTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the profi-air 180 and is the answer not in the manual?

Questions and answers

Summary of Contents for FRÄNKISCHE profi-air 180

  • Page 1 profi-air 180 flat condensate pump ® Installation and operating instructions DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS...
  • Page 2: Table Of Contents

    The decisive role with regard to the data on products and services is always played by the order placed, the product actually purchased and the documentation in connec- tion with it, or the information provided by our specialist staff in each specific individual case. FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 3: General

    Installation of the profi-air condensate instructions near the device during pump must be carried out accord- the entire life of the profi-air conden- ing to applicable local construction, sate pump. safety and installation regulations. FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 4: Intended Use

    The condensate pump is there is condensate. The delivery to the ventilation unit. FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 5: Technical Data

    12 l/h (with a pumping head of 0 m) Max. pumping head: 10 m Max. suction head: Noise level: 25 dB(A) (with a distance of 1 m) 4.2 Capacity diagram 230 V Mini Orange Discharge flow [l/h] FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 6: Safety

    Please note that the condensate pump must always be installed on the fresh air / exhaust air side of the venti- lation unit. This may vary depending on the operating mode (A or B) of the profi-air 180 flat ventilation unit.
  • Page 7: Parts Overview Of The Entire Condensate Pump Kit

    2-pin connector plug to connect condensate pump to digital input on the control board profi-air 180 flat (high water level alarm signal) Inlet hose, Ø 12 mm x 210 mm (only required if the profi-air 180 flat ventilation unit has been installed vertically on the wall)
  • Page 8 5 Installation 5.2 Parts overview of the condensate pump max. 45° C FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 9 5 Installation purple grey brown blue Mode A Mode B RS485 RS485 Digital input Digital input 12 3 4 12 3 4 RS485 Digital input 12 3 4 FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 10 Digital input 12 3 4 12 3 4 RS485 RS485 Digital input 12 3 4 RS485 Digital input RS485 RS485 12 3 4 Digital input Digital input 12 3 4 12 3 4 FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 11 In addition, our “General Terms and Conditions” apply as amended, available at www.fraenkische.com. 8 Disposal Please do not dispose of the profi-air municipal waste consulting authority condensate pump with the normal about collection points and recycling household waste; please ask your possibilities. FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 12 Rooted in Königsberg – globally successful! Our facilities in Europe: Königsberg, Germany (headquarters) Bückeburg, Germany Schwarzheide, Germany Okříšky, Czech Republic St.-Leonards-on-Sea, Great Britain Moscow, Russia Yeles/Toledo, Spain Torcy-le-Grand, France Ebersbach/Fils, Germany Our facilities in Africa: Hermsdorf, Germany Ben Arous, Tunisia Mönchaltorf, Switzerland Casablanca, Morocco Milan, Italy...