OPERATING
INSTRUCTIONS
Donato's Master Timer
Model No. 740-T88D
Model
Description
740-T88D
Eight Channel
ELECTRICAL
740-T88D
120 Volts
50-60 Hz
Printed in 2000
Prince Castle Inc.
355 East Kehoe Blvd.
Tel: (630) 462-8800
Toll Free: 1-800-PCASTLE

TABLE OF CONTENTS

Installation ..................................................................... 2
Programming ................................................................. 2
Operation ....................................................................... 3
Cleaning ........................................................................ 4
Parts List ....................................................................... 4
Exploded View .............................................................. 5
Troubleshooting ............................................................ 5
Wiring Diagrams ........................................................... 6
LIMITED WARRANTY
This product is warranted to be free from defects in
material and/or workmanship for a period of two
years from date of original installation, not to ex-
ceed 30 months from date of shipment from our
factory.
Any component which proves to be faulty in material
and/or workmanship will be replaced or repaired (at
the option of Prince Castle, Inc.) without cost to the
customer for parts or labor.
This warranty is subject to the following exceptions/
conditions:
This equipment is portable, charges for on loca-
!
tion service (e.g. trip charges and mileage) are
not included in the provisions of this warranty.
Use of any non-genuine Prince Castle parts
!
voids this warranty. All genuine Prince Castle
replacement spare parts are warranted for ninety
(90) days from date of purchase.
All work must be performed by an authorized
!
Prince Castle Service Agency. Failure to do so
will void this warranty.
Damage caused by carelessness, neglect, and/
!
or abuse (e.g., dropping, tampering or altering
parts), equipment damaged in shipment, by fire,
flood or an act of God is not covered under this
warranty.
Carol Stream, IL 60188
l
Fax: (630) 462-1460
l
PAGE
740-538

Advertisement

loading

Summary of Contents for Prince Castle Merlin II

  • Page 1: Table Of Contents

    Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts or labor. This warranty is subject to the following exceptions/...
  • Page 2: Installation

    Attach timer to mount- ing brackets placing star washer between bracket and timer. 1.Press and hold the PRINCE CASTLE logo for six seconds. The TIME displays will change from DISPLAYS AND INDICATORS “----” to “Prog” and a beep will sound.
  • Page 3: Operation

    8. You can change the sound level of the alarm in is the stage #2 program mode. Change the time RUN MODE. Press and hold the PRINCE CASTLE using the UP and DOWN ARROW Buttons. logo; then, within six seconds, press either the SCAN UP Arrow button or the SCAN DOWN Arrow button.
  • Page 4: Cleaning

    ACCELERATE CHANNEL 8 PART LIST 1. Accelerator mode 1=2.5 hours. LED is red during ITEM PART NUMBER DESCRIPTION timing. After timed out, LED will be flashing green and alarm will have a two-tone beep until pressing 69-079S Plastic Rivet (Pkg. Of 2) 69-079S the accelerator channel button cancels the timer alarm.
  • Page 5: Exploded View

    EXPLODED VIEW TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION A. No displays or indicators lit. Unit unplugged. Plug unit in. Store's circuit breaker blown. Reset breaker. Defective transformer. Replace Main Circuit Board. Circuit inoperable. Replace Main Circuit Board. B. Absence of Audio Alarm. Speaker inoperable.
  • Page 6: Wiring Diagrams

    WIRING DIAGRAM 740-T88D...