  • Page 1 MANUAL DOOR DRIVE OPR800 English REV.2 11/09/2019...
  • Page 2: Table Of Contents

    81-20/50 Parameters (M7)........................10 4.2.9. Diagnostic Parameter (M8) ........................11 FUNCTIONS ................................12 5.1. IxT Protection..............................12 5.2. Security Test Vega Light Curtain ........................12 Reopening to the floor – EN81-20/50 ......................12 5.3. DIAGNOSTIC................................. 13 6.1. LED ................................. 13 6.2.
  • Page 3: General Information

    CLOSED OBSTR OPENED PHOT ENCODER PINOUT Connector for Vega Light Curtain RX Connector for Vega Light Curtain TX JP3-JP4 Connector for Mini Keypad (2 Digit + 4 buttons) Connector for encoder Connector for input (clean contact or extern voltage) •...
  • Page 4: Start Up

    ENCODER 3. Connect the power supply to the JP14 connector. 4. When the OPR800 is turned on, it performs the phase tuning of the motor (you see a vibration for a few seconds). 5. Verify that when the phase-tuning ends, the doors move slowly close to complete the closure.
  • Page 5: Connections

    CONNECTIONS 3.1. Opr800-Control Panel CLEAN CONTACT INPUT OUTPUT JP10 CLOSED OBSTR. OPENED PHOT. CLOSED OPENED Pho tocell/ OBSTRUCTION Limit Switch Limit Switch Light Curtains Control Panel EXTERN VOLTAGE INPUT JP10 OUTPUT OPENED CLOSED OBSTR. PHOT. CLOSED OPENED Pho tocell/ OBSTRUCTION...
  • Page 6: Opr800-Vega Light Curtains

    3.2. Opr800-Vega Light Curtains 3.3. Opr800-Light Curtains/Photocell...
  • Page 7: User Interface

    USER INTERFACE 4.1. Dipswitch 4.1.1. NOT USED NOT USED 4.1.2. OFF (Motor Rotation FORWARD) ON (Motor Rotation REVERSE) 4.1.3. NOT USED NOT USED...
  • Page 8: Tst800

    4.2. TST800 4.2.1. Opening Profile (MO) The first 4 parameters are position references expressed as a percentage of the total length of the stroke learned. The other parameters are speed references expressed as a percentage of the maximum value (Nominal RPM). Menu Description o0 Start opening acceleration ramp...
  • Page 9: Closing Profile (M1)

    4.2.2. Closing Profile (M1) The first 5 parameters are position references expressed as a percentage of the total length of the stroke learned. The other parameters are speed references expressed as a percentage of the maximum value (Nominal RPM). Menu Description c0 Start closing acceleration ramp c1 End closing acceleration ramp...
  • Page 10: Torques (M2)

    4.2.3. Torques (M2) The parameters are current references expressed as a percentage of the maximum value of 2.5 A. Menu Description BRAKE: represents braking when the motor is not controlled. The lower the value, the more the engine is braked. Limit Switch Torque: represents the current threshold that must be exceeded (near the ends) to acquire DOOR CLOSED.
  • Page 11: Commands (M4)

    4.2.5. Commands (M4) Menu Description -O Open command: has priority over the elevator control board commands -C Close command: has priority over the elevator control board commands -d Default command: restore the original factory settings -L Learning command -P Reset command 4.2.6.
  • Page 12: Diagnostic Parameter (M8)

    4.2.9. Diagnostic Parameter (M8) Menu Description Last alarm: A1 = Over Current A2 = Motor/Encoder error A3 = Encoder Inc. A4 = IxT Protection A5 = Overtemperature A6 = EEprom Error A7 = Under Voltage A8 = Light Curtain Error H1 Learned stroke length - centimeters Number of openings P1 = OFF;...
  • Page 13: Functions

    • On TST800 from menu M6, with parameter B2 = 1. If the safety test is enabled, the door drive when the door is completely closed performs a test on the Vega Light Curtain to check if it works correctly.
  • Page 14: Diagnostic

    DIAGNOSTIC 6.1. Number Led Status Door Status Color of flashes Green Fixed Funzionamento normale Rifasamento o Alim. d’emergenza Green Blinking Blinking Alarm: Over Current Blinking Alarme: Motor/Encoder Error Blinking Alarm: Encoder Inconsistent Blinking Alarm: IxT Protection Blinking Alarm: Over Temperature Blinking Alarm: EEProm Error Blinking...
  • Page 15: Tst800

    6.2. TST800 When not on the menu, the status of the door or the current error can be viewed on the keypad screen: Symbol Description DOOR CLOSED DOOR OPENED WAITING… OPENING CLOSING NUDGING OUT “OBSTR.” = ON OUT “PHOT.” = ON CURRENT ERROR: E1 →...
  • Page 16: Default

    DEFAULT OPENING PROFILE (M0) PAR. TST800 Description Default Start opening acceleration ramp End opening acceleration ramp Start opening deceleration ramp End opening deceleration ramp Coupling cam opening speed Maximum opening speed End opening speed Learning speed CLOSING PROFILE (M1) PAR. TST800 Description Default Start closing acceleration ramp...
  • Page 17: Dimensions

    DIMENSIONS 270 mm 106 mm 118 mm 252 mm...
  • Page 18: Trubleshooting

    TRUBLESHOOTING PROBLEMA Soluzione The doors do not move or move jerkily Check the motor and encoder wiring - "PWR" LED, 3 red flashes. - E3 on the TST800 display The doors always move Slowly To do Learning procedure (chapter 2) Check if the door open when you press quikly the push The doors do not open button.
  • Page 19 Vega srl Via degli Appennini 12/13 63845 - Ponzano di Fermo (FM) P.iva 01578140442 Phone: + 39 (0)734 275405 -Fax: +39 (0)734 636098 www.vegalift.it...

Table of Contents