These installation instructions apply to the VEGA D4A Retrofit Kit models designated below.
Model - Watts - CCT - Type - Acc. Cap - Mount Down/Up - Control - Custom
D4A - 20G - 22K - T5M -
D4A - 30G - 30K - T3M -
D4A - 40G - 40K
D4A - 50G - 50K
D4A - 60G -
NA – No Up Light
Key:
D – Base Down, U – Base Up
Universal Mounting Plates to replace socket mounts: F63 – 6.25", F65 – 6.5", F70 – 6.95". F80 – 7.92"
DIM – Dimming controlled by external lighting control node.
PRC – Wired for future connection to a wireless lighting control node with 0 – 10VDC dimming.
CAUTION
• THIS IS A LINE DRIVEN 120VAC-277VAC LAMP. DO NOT INSTALL ABOVE 277VAC.
• THIS LAMP IS NOT RATED FOR USE WITH HID BALLAST OR EXTERNAL LED DRIVER.
• DO NOT USE WITH STANDARD DIMMERS.
• SUITABLE FOR DAMP LOCATIONS – DO NOT USE WHERE DIRECTLY EXPOSED TO WATER.
• THIS DEVICE IS NOT INTENDED FOR EMERGENCY LIGHTING OR FOR USE WITH
EMERGENCY EXITS.
• PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION.
•
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRES WIRING, POWER SUPPLY, OR OTHER
ELECTRICAL PARTS MAY BE DAMAGED WHEN DRILLING FOR INSTALLATION OF RETROFIT KIT HARDWARE.
INSPECT WIRING AND COMPONENTS FOR DAMAGE.
•
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT KIT INSTALLATION REQUIRES KNOWLEDGE
OF LUMINAIRES ELECTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A
QUALIFIED ELECTRICIAN.
•
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN LUMINAIRES THAT HAVE THE
CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS AND
WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOT EXCEED THE INPUT RATING OF THE
LUMINAIRE.
•
WARNING - TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET
METAL OR OTHER SHARP OBJECTS.
•
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS
DURING KIT INSTALLATION.
•
ONLY THOSE OPEN HOLES INDICATED IN THE PHOTOGRAPHS AND/OR DRAWINGS MAY BE MADE OR
ALTERED AS A RESULT OF KIT INSTALLATION. DO NOT LEAVE ANY OTHER OPEN HOLES IN AN ENCLOSURE
OF WIRING OR ELECTRICAL COMPONENTS.
•
THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE
INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE
ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL
REGULATIONS FOR ELECTRICAL INSTALLATIONS.
AVERTISSEMENT
•
AVERTISSEMENT - RISQUE D'INCENDIE OU DE CHOC ÉLECTRIQUE. LE CÂBLAGE DES LUMINAIRES, LES
BLOCS D'ALIMENTATION OU LES AUTRES COMPOSANTS ÉLECTRIQUES PEUVENT SUBIR DES DOMMAGES
LORS DU PERÇAGE EN VUE D'INSTALLER LA QUINCAILLERIE D'UN NÉCESSAIRE DE MODERNISATION.
VÉRIFIER SI LES CÂBLES ET LES COMPOSANTS SONT ENDOMMAGÉS.
•
AVERTISSEMENT - RISQUE D'INCENDIE OU DE CHOC ÉLECTRIQUE. L'INSTALLATION DE CE NÉCESSAIRE DE
MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION ET LE FONCTIONNEMENT
DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES ASSOCIÉS. TOUTE PERSONNE QUI N'EST PAS
QUALIFIÉE NE DOIT FAIRE AUCUNE TENTATIVE D'INSTALLATION ET DOIT CONTACTER UN ÉLECTRICIEN
QUALIFIÉ.
5024804 REV C
D4A PRC LED RETROFIT KITS
NA
- F63
D
F65
U
F70
F80
C####
Vega Light Control Systems ● Holland, Michigan 49423
INSTALLATION GUIDE
Applications
-
DIM
-
PRC
Retrofit Kits for Post Top and Pendant
Style Luminaires With 19" Globes and
-
Vertical Lamps.
#### - Custom Fitter Specific Mounts
Fixed Plate PRC D4A
20211001
Need help?
Do you have a question about the D4A and is the answer not in the manual?
Questions and answers