Advertisement

1
SYSTEM OVERVIEW ............................................................................................ 2
1.1
DISPLAY CONSOLE ..............................................................................................................2
1.2
MASTER SWITCH MODULE ................................................................................................3
1.3
GROUND SPEED SENSOR ..................................................................................................3
1.4
FEEDBACK SENSOR ............................................................................................................3
1.5
CONTROL VALVE .................................................................................................................3
1.6
HARNESSES ..........................................................................................................................3
2
CONSOLE INTERFACE ........................................................................................ 3
2.1
OPERATE MODE ................................................................................................................... 3
2.1.1
Primary Operate ........................................................................................................3
2.1.1.1 Product Flow Indicator ...............................................................................................4
2.1.1.2 Channel Selection ......................................................................................................4
2.1.1.3 Manual Valve Mode ...................................................................................................4
2.1.1.4 Manual Ground Speed ...............................................................................................5
2.1.2
Accessory (If Configured) ..........................................................................................5
2.1.3
Accumulators ............................................................................................................. 5
2.1.4
Product Level (If Enabled) .........................................................................................5
2.1.5
Alarm History ............................................................................................................. 5
2.2
SETUP MODE ........................................................................................................................6
2.2.1
Setup Liquid Pressure ................................................................................................6
2.2.2
Setup Liquid Flow ......................................................................................................8
2.2.3
Setup Anhydrous ........................................................................................................9
2.2.4
Setup for Granular and Seeding .............................................................................. 10
2.2.5
Setup RPM ............................................................................................................... 11
2.3
SYSTEM MODE ................................................................................................................... 11
2.3.1
Ground Speed Cal ................................................................................................... 12
2.3.2
Auto Gain Cal .......................................................................................................... 12
2.3.3
Digital Acc 1 ............................................................................................................. 12
2.3.3.1 Digital Pulse ............................................................................................................. 13
2.3.3.2 Logic Level ............................................................................................................... 13
2.3.4
Service ..................................................................................................................... 13
2.3.4.1 Accumulators ........................................................................................................... 13
2.3.4.2 System Overrides .................................................................................................... 13
2.3.4.3 System Information.................................................................................................. 13
2.3.4.4 Trouble Shooting ...................................................................................................... 13
2.3.4.5 Configuration ........................................................................................................... 14
2.3.4.6 System Units ............................................................................................................ 16
2.3.4.7 Display Logo ............................................................................................................ 16
2.3.4.8 Volume Adjust .......................................................................................................... 16
2.3.4.9 Clear Alarms ............................................................................................................ 16
2.3.5
Password Menu ....................................................................................................... 16
2.4
APPLICATION CALIBRATION AND FINE TUNING ........................................................... 17
2.4.1
Nozzle Calibration ................................................................................................... 17
2.4.2
Liquid Flowmeter Calibration ................................................................................... 18
2.4.3
Spreader Constant Calibration ................................................................................. 19
2.4.4
Anhydrous Flowmeter Calibration ........................................................................... 19
Appendix A .......................................................................................................................... 19
Appendix B .......................................................................................................................... 24
Appendix C .......................................................................................................................... 26
Appendix D .......................................................................................................................... 28
11001-1248-200306
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Land Manager SE and is the answer not in the manual?

Questions and answers

Summary of Contents for Dickey-John Land Manager SE

  • Page 1: Table Of Contents

    SYSTEM OVERVIEW .................... 2 DISPLAY CONSOLE ......................2 MASTER SWITCH MODULE ....................3 GROUND SPEED SENSOR ....................3 FEEDBACK SENSOR ......................3 CONTROL VALVE .........................3 HARNESSES ..........................3 CONSOLE INTERFACE ..................3 OPERATE MODE ........................3 2.1.1 Primary Operate ......................3 2.1.1.1 Product Flow Indicator ....................4 2.1.1.2 Channel Selection ......................4 2.1.1.3 Manual Valve Mode ....................4 2.1.1.4 Manual Ground Speed ....................5...
  • Page 3: Master Switch Module

    1.2 Master Switch Module The master switch has three positions OFF, AUTO, and MANUAL. AUTO position is where the system is controlling based on actual ground speed and the current application rate. MANUAL is a momentary position that allows the system to control at a preprogrammed manual ground speed. The manual ground speed value can be changed under the setup menu.
  • Page 5: Manual Ground Speed

    CHANNEL 1 MANUAL GAL/AC Target Rate indicates MANUAL 12.7 AC OPERATE Screen w/Master Switch in OFF Position CHANNEL 1 20.0 GAL/AC Target Rate Display is in Small font to indicate 15.5 AC MANUAL Operation OPERATE Screen w/Master Switch in ON Position Figure 2C Manual Mode Screens 2.1.1.4 Manual Ground Speed When manual ground speed is active, the ground speed readout will display MANUAL.
  • Page 6: Setup Mode

    The next press of the OPERATE key will take you back to the Primary Operate screen. If you are on any of the operate screens, the ENTER function key is a shortcut back to the primary operate screen. 2.2 Setup Mode This set of screens is used to setup the desired configuration that has been selected under the SERVICE, CONFIGURATION menu.
  • Page 7 MIN OVERRIDE A minimum ground speed that is used by the Land Manager® SE when actual ground speed is below this value. SHUT OFF SPEED The minimum ground speed allowed before the system stops operation. NUM OF SECTIONS The total amount of boom sections used. Maximum of 6 boom sections. NOZZLE SPACING Distance between nozzles.
  • Page 8: Setup Liquid Flow

    2.2.2 Setup Liquid Flow APPLICATION RATE The target rate for applying product. INC\DEC RATE The desired increment/decrement value for changing the application rate during application. Note the channel must be selected on the primary operate screen for the INC/DEC to work. MINIMUM RATE Minimum application rate that the system can be decreased to.
  • Page 9: Setup Anhydrous

    2.2.3 Setup Anhydrous Be sure to read and observe the anhydrous safety precautions under the configuration section 2.3.4.5 before proceeding. APPLICATION RATE The target rate for applying product. TANK PRESSURE Pressure read from the nurse tank. If gauge is not functioning, see chart below.
  • Page 10: Setup For Granular And Seeding

    12V ON YES indicates that 12V activates the solenoid. NO indicates that grounding activates the solenoid. NUM KNIVES SEC (1-6) The number of knives for that given section. USE DENSITY OF NITROGEN will display in actual pounds of nitrogen per acre. will display in actual pounds of NH per acre.
  • Page 11: Setup Rpm

    PRODUCT LEVEL When ENABLED, the amount of product remaining is displayed on the PRODUCT LEVEL operate screen. The product level decreases as material is applied. When this is ENABLED the reset level and alarm level values are added to the SETUP menu structure and needs to be set. NOTE: After enabling this feature, the product level must be set on the PRODUCT LEVEL operate screen before application is to start, see section 2.1.4.
  • Page 12: Ground Speed Cal

    START CAL To capture the pulses over the defined course, select the START CAL by pressing the function key. When you are up to the operating speed and even with the start of the predefined course, press the ENTER function key. The calibration routine will start accumulating the pulses.
  • Page 13: Logic Level

    UP and DOWN arrow keys on the primary operate screen when the channel has been selected and the master switch is in AUTO. 2.3.4.3 System Information This screen provides the software version of the Land Manager® SE along with the DICKEY-john address and technical support phone number. 2.3.4.4 Trouble Shooting This menu has tests that can help the operator trouble shoot the Land Manager®...
  • Page 14: Configuration

    The range is 40 to 250 Hz. NOTE: The anhydrous configuration will not have a choice for drive type or frequency. The anhydrous configuration is only for DICKEY-john servo valves. Be sure to read and observe the following safety precautions before proceeding.
  • Page 15 7. Store and handle anhydrous ammonia in accordance with state and local regulations. Where no state or local regulations exist, use only equipment that is constructed in accordance with The Fertilizer Institute Standards. 8. Ensure all ammonia is out of the system before disconnecting or disassembling any parts. Be alert for frosting which is a certain indication of trapped liquid ammonia vaporizing.
  • Page 16: System Units

    NOTICE: DICKEY-john retains the right to make changes to these specifications at any time without notice. 2.3.4.6 System Units By selecting this menu, the operator will be asked to press the ENTER function key to change the units.
  • Page 17: Application Calibration And Fine Tuning

    CHANNEL SETUP There are three access states for the SETUP menu ACCESS, NO ACCESS, OR PARTIAL. ACCESS All of the SETUP constants can be accessed without the password. NO ACCESS None of the SETUP constants can be accessed until the password is entered.
  • Page 18: Liquid Flowmeter Calibration

    Nozzle Calibration Device Measure and record the output of all of the nozzles along with the nozzle pressure. Average all of the nozzles and use that number as the NOZZLE CONSTANT. Then enter the pressure used while calibrating as the NOZZLE PRESSURE. Catch Test Using a Calibrated Container The second method of nozzle calibration is to catch the water in a calibrated container.
  • Page 19: Spreader Constant Calibration

    Once the area is covered, record the tank weight. Calculate the amount of anhydrous used and compare that to the controllers accumulated values. Determine the percent of error and adjust the K-factor accordingly. A typical DICKEY-john anhydrous flowmeter K-factor starting point is 2.15 P/In...
  • Page 20 CONSOLE STATISTICS SERIAL NUMBER SOFTWARE VERSION Granular Seeding Anhydrous Granular Spreader Application Rate Application Rate Application Rate Tank Pressure Density Density Inc/Dec Step Inc/Dec Step Inc/Dec Step Minimum Rate Minimum Rate Minimum Rate Maximum Rate Maximum Rate Maximum Rate Spreader Constant K-Factor Spreader Constant Reset Level...
  • Page 22 Land Manager SE Ver 1.5 Setup Screens Application Rate Tank Pressure Application Rate Inc/Dec Step Inc/Dec Step Minimum Rate Minimum Rate Maximum Rate Maximum Rate Anhydrous K-Factor K-Factor Reset Level (if product level enabled) Reset Level (if product level enabled)
  • Page 23 11001-1248-200306...
  • Page 24 APPENDIX B ERROR CODE DEFINITIONS QUICK REFERENCE TROUBLESHOOTING SELF-TEST ERROR MESSAGES All self-tests must successfully pass at start-up before the system becomes operational. A self-test failure appears on the display with an error message. Other types of errors show error messages as listed below. Two types of self-test errors may occur during start-up.
  • Page 25 Type 6 Error - 600 thru 699 series - System failure. Restart system to see if error failure clears. If it cannot be cleared after several attempts, record all the information on the screen and then call DICKEY-john Service for assistance. • Alarm 635 - MEMORY READ ERROR •...
  • Page 27 Figure C2. Ball Valve in Open Position During installation of a servo return valve, the valve assembly must be in the open position when the actuator is placed on the valve body as shown in Figure C2. If using a 2-inch or 3- inch butterfly valve, remove the four bolts at the bottom of the actuator and rotate until the coupling post are in the position shown in Figure C3.
  • Page 28 APPENDIX D COMMON OPERATOR PROBLEMS TROUBLESHOOTING TIPS Clearing Minor Problems ® Until you become familiar with the basic functions of Land Manager SE, small problems may arise. If a problem does occur, follow the approach outlined below: • Carefully define the problem. •...
  • Page 29 Alarm sounds and the display indicates an application error while driving through the field. • Console doesn’t see the correct application rate for the speed you are driving. Lower the driving speed; check the application rate entered into the Setup mode. System won’t run in AUTO.
  • Page 30 DICKEY-john WARRANTY DICKEY-john warrants to the original purchaser for use that, if any part of the product proves to be defective in material or workmanship within one year from date of original installation, and is returned to DICKEY-john within 30 days after such defect is discovered, DICKEY-john will (at our option) either replace or repair said part.

Table of Contents