Sage 925VST User Manual
Hide thumbs Also See for 925VST:
Table of Contents

Advertisement

Quick Links

SAGE INSTRUMENTS
925VST VoP Service Tester
SAGE
VoP Service Tester
MOS = 4.50
F1
F1
CLR
INFO
BACK
1
2
QZ
ABC
Volume
4
5
GHI
JKL
7
8
TALK
PRS
TUV
ON/
*
0
OFF
+
USER'S MANUAL
Version 1.2
925VST
F2
F2
NEXT
3
DEF
6
MNO
9
WXY
#
-

Advertisement

Table of Contents
loading

Summary of Contents for Sage 925VST

  • Page 1 SAGE INSTRUMENTS 925VST VoP Service Tester SAGE 925VST VoP Service Tester MOS = 4.50 INFO BACK NEXT Volume TALK USER’S MANUAL Version 1.2...
  • Page 2: Table Of Contents

    OVERVIEW ..............................4 925VST ............................. 4 (VTS)........................... 4 YSTEM VTS F ............................5 EATURES General Features............................. 5 Other Tests ............................. 6 925VST T ......................7 NVIRONMENT GETTING STARTED..........................9 ..............................9 NPACKING ......................... 9 HARGING THE ATTERIES Initial Charge ............................9 Recharging............................
  • Page 3 Test Setup ................................22 Action ................................23 Upgrading the 925VST Application Software..................24 ............................24 EMPLATES Call Progress and DVM........................26 SMOS ..............................26 DTMF Callback............................ 27 Echo Sounder ............................27 100 Responder ............................28 102 Responder ............................28 PVIT Measure ............................29 Help ..............................
  • Page 4: Overview

    Overview The Sage 925VST The Sage 925VST is the field component of the Sage Voice over Packet Test System (VTS). The 925VST initiates VoP service qualification and maintenance tests from a customer premise or any 2-wire or 4-wire access point to a Sage responder that is typically located in the central office.
  • Page 5: Vts Features

    VTS Features The Sage VoP Test System can: • Test End-to-End Voice Quality (QoS) Mean Opinion Score (MOS) ο Comfort Noise Level ο Audio Level ο • Troubleshoot and Isolate Echo Impairments Detect up to 4 echoes ο Echo Level ο...
  • Page 6: Other Tests

    Other Tests Other Tests The 925VST may come equipped with other tests that do not require a Sage farend responder or that enable the 925VST to emulate a farend responder. They provide detailed results that can be viewed only on the 925VST. These tests may include: •...
  • Page 7: The 925Vst Test Environment

    94xRTS/950RTS 925VST Use the Sage 925VST hand-held unit in the field to connect to the voice line being tested. The interface can be at a customer premises or at any 2-wire or 4-wire access point. The 925VST can connect to customers served by: •...
  • Page 8 At the conclusion of the test, the 925VST displays an immediate result and pass/fail notification if pass/fail template is enabled. Using menus on the 925VST, the technician can view stored detailed results of each portion of the test. During the test, the technician can listen to the dial tone, progress tones, and other audible sounds.
  • Page 9: Getting Started

    2. Plug the AC adapter power cord into the appropriate AC outlet. 3. Plug the cord from the AC adapter into the power port on the bottom of the 925VST. Leave the power cord plugged in for at least two hours to allow the batteries to fully charge.
  • Page 10: Recharging

    3. Plug the cord from the AC adapter into the power connector on the 925VST. 4. Allow the 925VST to charge for two hours. NOTE: You can use the 925VST while it is connected to the AC adapter unless it is being charged for the very first time.
  • Page 11: Keypad

    Use the CLR key to erase the current data in a data entry field. Press and hold the CLR key to display the Main Menu. Use the CLR key to delete results when reviewing results. (Note: The 925VST will ask for confirmation before deletion.) © 2004 SAGE INSTRUMENTS...
  • Page 12: Info

    (1) the AC adapter is not plugged in, (2) no test is in progress, (3) there is has been no key press for 10 minutes, and (4) the unit is not in talk mode. The 925VST will power itself on when a call comes in.
  • Page 13: Telephone Keys

    ELEPHONE The 925VST telephone keypad performs many functions and can be used for both alphabetic and numeric (alpha-numeric) data entry. Use the keypad for: • making menu selections • entering telephone numbers • entering other information (e.g., your identification number, names for responder phone lists, selecting display...
  • Page 14: Setting Up The Basic Operating Features

    Basic operating features include selecting the type of line used, enabling audible alerts, and brightening or darkening the display screen. You can use the Setup screens (listed below) to change the basic operating features of the 925VST. • Interfaces (line types and ports) •...
  • Page 15: Serial Port

    925VST to your computer. NOTE: In previous versions, users had to manually place the 925VST in Download Mode. This is now done automatically; you do not need to change the mode of the 925VST to download software. • For more information on setting up the 925VST using the 925Install application on your computer, see 925Install Tool on page 20.
  • Page 16: Testline Timeout

    Echo Generator (responder mode) you can use this setting to specify how long the 925VST will run a test. When the maximum run-time has expired, the test display switches to the results display. At the Testline Timeout screen, enter the number of seconds before the 925VST automatically ends a test.
  • Page 17: Display Contrast

    The phone list contains the phone numbers to farend responders that the 925VST calls to Edit Phone List conduct tests. The list works like a speed dial function on a telephone. The 925VST can store Name: up to 9 phone numbers, each with 18 digits. <Number>...
  • Page 18: Responder Mode

    To view the current parameters, press the INFO button. PVIT S Use DTMF digit 3 to specify PVIT. The 925VST reboots to a state in which it emulates a farend test responder for the test. In this state the 925VST waits for a “seizure” stimulus from the farend.
  • Page 19: Echo Generator

    PVIT signal to the far end. At the far end, a 935AT or 925VST configured for PVIT Receive analyzes the incoming signal for signs of transmission impairments. To view the current parameters, press the INFO button. For information on how to stop a test in PVIT mode, see Remote Control of the 925VST on page 38.
  • Page 20: Minimum On And Off Requirements

    RS-232 cable to the 925VST. You can also use the 925Install Tool to upgrade the 925VST application software. All of these options are described in the following sections.
  • Page 21: Phone List

    HONE In the Phone List area, you can specify up to nine phone numbers. These are the phone numbers of farend responders that the 925VST calls to conduct tests. Each phone number can have up to 18 digits. For each phone number, you must designate the following items: •...
  • Page 22: Test Setup

    For more information on creating and download templates, see Test Templates on page 24. • Tx Level Point — The default on the 925VST TX Level Point is 0dB; the allowable range is –50dB to 0dB.
  • Page 23: Action

    • Save to local configuration file — This action saves the current settings to a file on your computer. You can then load this file at a later time. • Set 925 to factory defaults — This action resets the settings on the 925VST to the factory defaults.
  • Page 24: Upgrading The 925Vst Application Software

    You can use the 925VST Template UI application to create and download test templates. The application is available on the 925VST CD-ROM. A template is a set of threshold criteria that determines whether a test passes or fails. Templates can be enabled only if a valid template has been installed.
  • Page 25 • 38400 bps • 8 data bits • no parity 5. Click “Download Template” in the lower right side of the 925VST Template UI application window. 6. Click the desired template in the file selection window, then click “Select”. If the file transfer is successful, a message will show whether the template is enabled or disabled.
  • Page 26: Call Progress And Dvm

    — voice clarity merit score), BW (useable effective bandwidth), –FS (net total of negative frame slips — a measure of voice signal expansion [gapping]), +FS (net total of positive frame slips — a measure of voice signal compression [jerking]), gain, noise, and codec. © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...
  • Page 27: Dtmf Callback

    Use this screen to set acceptable parameters for the ring frequency and ring voltage. Echo Sounder Echo Sounder Echo Sounder Echo Sounder Use this screen to set acceptable parameters for the level and delay of up to four echoes. © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...
  • Page 28: 100 Responder

    Use this screen to set acceptable parameters Cmsg, 3k flat, and ERL. 102 Responder 102 Responder 102 Responder 102 Responder Use this screen to set acceptable parameters for the noise C-notch, S/N, and level. © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...
  • Page 29: Pvit Measure

    Help Use this screen to set acceptable parameters for the duration and percentage for packet loss, compressive packet slip, and expansive packet slip; the duration and average for voice clip; and the noise average. © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...
  • Page 30: Using The 925Vst

    • Responder phone numbers are stored or available for manual entry, and • Appropriate farend responders are available. Connecting to the Line Under Test In most cases, you will connect the 925VST to a test access point downstream from the IAD, residential gateway, or IP/Digital Phone. Bottom Ports on the 925VST...
  • Page 31: Running Tests

    You can establish the ground connection via the ground cable supplied with the 925VST. The ground cable has a banana plug at one end and a large alligator clip housed in an insulating boot at the other end. 1. Insert the banana plug into the round jack in the center of the bottom of the 925VST.
  • Page 32: Aborting A Test

    Work Orders. Up to 100 work orders can be stored on the 925VST. You can use the last entry in the list to print or export captured results for all work orders the serial port.
  • Page 33: Test Result Types

    SMOS Director indicate pass or fail respectively. MOS: 4.57 P • MOS: Mean Opinion Score — Voice clarity Noise: 18 dBrnC P merit score [1.00 to 5.00] -FS: 0 ms F • Noise: Comfort Noise © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...
  • Page 34: Echo Sounder

    • -PS: Negative Packet/Frame Slips — A measure 000:00:08 3 of voice signal expansion (gapping). Includes Duration 10ms P total elapsed test time, net total -PS impairment Count time, -PS event count, and Percentage: 0.50%P -PS percentage of total time. © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...
  • Page 35: Faxtx

    CED tone. • CED/DIS Detect T/O (CED or DIS detection time out) — The Sage fax emulator has not detected a valid CED tone (fax answer tone) or DIS packet (digital identification signal, which contains the capabilities of the fax machine) from the answering device within 15 seconds after call establishment.
  • Page 36: Dtmf Callback

    DCS signals due to communication link problems. It requests the Sage fax emulator to resend the DCS and training sequences. • CFR Detect T/O (detection time out) — The Sage fax emulator has not detected the CFR packet after the completion of the training and TCF sequences within 10 seconds.
  • Page 37: Dvm

    Work Order: 1237777098 Exporting Results Results can be exported in space delimited, ASCII format through the 925VST serial port. Result should work with any PC terminal emulator program set to VT100 (i.e. Hyperterm). There are three levels of result export: •...
  • Page 38: Remote Control Of The 925Vst

    Setting Up Setting Up 1. Connect the RS-232 cable to the small DIN connector at the top of the 925VST. 2. Connect the other end of the RS-232 cable to an available serial port configured for 38400 baud, 8 data bits, and no parity (8N1).
  • Page 39: Interface

    EFAULT settl [smos|pvit|egen] or sttl [s|p|e] Use this command to set the type of test line the 925VST will be when it answers an incoming call in responder mode. If the 925VST is not in responder mode, this command places it in the specified mode. If the 925VST is already in responder mode, the 925VST must be rebooted for the new responder mode to take affect.
  • Page 40: Set Smos Test Line Parameters

    America, Psophometric for all other places. • level is test signal level in dBm and must be an integer from –30 to 0. If you send the command without any parameters, the 925VST will report the current pvit PVIT test line parameters.
  • Page 41: Test Line Stop

    Login> prompt is longer displayed. • Type “i” and press enter to disable the 925VST inactivity power-off timer. The 925VST acknowledges this command by returning “ok”. The following table contains an overview of the test level commands. Details about each command follow.
  • Page 42: Setup

    Using the 925VST as a Telephone When the 925VST is connected to a working phone line, you can use it as a telephone handset. A telephone speaker and microphone are located on the back of the 925VST. The speaker volume is automatically adjusted to a level suitable for use as an earphone.
  • Page 43 3. Dial the desired number, or press NEXT to dial the displayed number. Dial access numbers and area codes just as you would from a regular telephone on the line. 4. To hang up, press the TALK key. © 2004 SAGE INSTRUMENTS 9100-0925-01 V1.2...