Charge Battery & Battery Set-up Attach & Operate the Control Cable Bleeding the System Pump Operation Setting the Pressure Operating 4-Way Control Valve Huck 964 Powerig ® Diagram Spare Parts & Accessories Preventative Maintenance Troubleshooting 14-15 Support Locations September 28, 2022...
Declaration of Conformity Manufacturer: Huck International, LLC, Industrial Products Group, 1 Corporate Drive, Kingston, NY, 12401, USA Description of Machinery: Models 968 Powerig® family and specials based on their design (e.g. PR####). Relevant provisions complied with: • Council Directive related to Machinery (2006/42/EC) • Supply of Machinery (Safety) Regulations 2008...
Page 3
• This high pressure hose is not to be used other than assembled in a genuine HUCK tool or hose assembly or used as a replacement hose of a genuine HUCK tool or hose assembly.
Safety Instructions I. GENERAL SAFETY RULES: 2. Disconnect the assembly power tool from energy 1. A half hour long hands-on training session with quali- source when changing inserted tools or accessories. 3. Be aware that failure of the workpiece, accessories, or equipment.
Page 5
Safety Instructions VI. WORKPLACE HAZARDS: VIII. VIBRATION HAZARDS: 1. Beware of slippery surfaces caused by use of the tool 1. Exposure to vibration can cause disabling damage to and trip hazards caused by the air line or hydraulic hose. the nerves and blood supply to the hands and arms. 2.
Model 964 Powerig® Hydraulic Power Source is a portable, battery-operated power source designed to operate all Huck hydraulic installation equipment, excluding Huck-Spin® tools. It operates using a 18 volt DC LI-ion 9Ah battery, which is recharged on a charger using 115 volt AC, 50-60 Hz, one-phase electrical power. The motor is rated at 18 volt DC, 144 W.
Principle of Operation Figure 2 FIGURES 2, 3 and 4 FIGURES 2, 3 and 4 The 18 volt DC battery-operated motor that drives the The 18 volt DC battery-operated motor that drives the hydraulic pump can be turned on by either pressing the on/off switch located at the top of the handle or by the on/off switch located at the top of the handle or by pressing the tool trigger when the tool is connected to...
Trade Names WHERE THE FOLLOWING TRADE NAMES ARE USED IN THIS MANUAL, PLEASE NOTE: WHERE THE FOLLOWING TRADE NAMES ARE USED IN THIS MANUAL, PLEASE NOTE: Loctite is a registered trademark of Henkel IP & Holding GMBH. is a registered trademark of The Chemours Company FC, LLC. Good Service Practices Foreign material introduced in the Hydraulic Unit will with a filter, keep quick-disconnect couplers clean by...
Charge the Battery New batteries must be charged Approx. 60 minutes of charging = 100% battery fuel. A. Ensure battery charger is plugged in. B. Slide battery pack into charger as shown and allow battery to charge. Battery Setup C. Once battery is adequately charged it can be installed on pump unit as shown. D.
WARNINGS must be understood before checking pressures. Connect Be sure that the hose from PULL PRESSURE on the hydraulic hoses from a HUCK hydraulic tool to the control panel runs to the port stamped with a letter ‘P’ on Powerig®.
1. Turn the valve control lever to the NEUTRAL position. 2. Start the pump by pressing and holding the tool trigger switch. 3. Turn lever to Pull Side, Huck tool will pull back installing the fastener. (Cutting the collar if cutter nose is used) 4.
Spare Parts and Accessories * Note: 220-240 VAC MWCH-18-240 charger and the T-124883CE are not included with the 964B, but are available as separate accessories. Spare Parts for Maintenance Options & Accessories These components are available independently. These components are available independently. DESCRIPTION PART # DESCRIPTION...
Preventative Maintenance WARNINGS: To help avoid personal injury: • Disconnect the battery from the pump before performing maintenance or repair procedures. • • use, and overall cleanliness and care given the pump. • Three hundred hours of use under general shop conditions is considered a standard change Bleeding the Air from the System Air can accumulate in the hydraulic system.
SOLUTION Electric motor does not run. 1. No voltage supply. 1. Check battery voltage. (Ensure its charged) 2. Broken Lead wire or defective 2. Contact your Huck distributor. WARNINGS: Disconnect power supply internal wiring. before removing cover. 3. Overheated motor has caused 3.
Page 15
2. Improperly adjusted external pressure regulator setting. Center 4-Way Control Valve with Huck Tooling” on page 11. 3. Internal or external leakage on 3. Remove the tool from the pump. If the pump hydraulic tool.
Huck’s written quotations, acknowledgments, and/or purchase orders. It is recommended the user secure specific, up-to-date data and information regarding each application and/or use of such products.
Need help?
Do you have a question about the HOWMET AEROSPACE Powerig 964B and is the answer not in the manual?
Questions and answers