Pressure Relief Procedure; Tank Assembly; Material Preparation - Graco 234414 Instructions Manual

2.5 and 5.0 gallon pressure tank
Table of Contents

Advertisement

Set-Up

Pressure Relief Procedure

WARNING
Pressure tanks remain pressurized until pressure is
manually relieved. To reduce the risk of serious injury
from pressurized fluid or accidental spray from gun,
always follow this procedure to relieve pressure in the
tank:
• Before you check or service any part of the spray
system.
• Before you loosen or remove the pressure tank
cover or fill port.
• Whenever you stop spraying.
1. Shut off air supply to the tank by closing air valve.
2. Pull ring on safety valve until pressure bleeds down.

Material Preparation

Follow manufacturer's directions for mixing and
preparing material.
Strain material using a fine mesh screen to prevent
foreign matter from entering and clogging passageways.
4

Tank Assembly

1. Install tank handle and lock nut by turning handle
clockwise 4-5 turns. Position handle so it is parallel
to safety valve branch tee.
2. Secure in place by tightening lock nut using a 9/16"
open end wrench.
Tank handle must be attached before installing
regulator.
3. Install regulator U10004 by tightening swivel
adapter nut U23040 onto nipple U09993. Position
unit so gauge is facing the same direction as safety
valve ring. Use 11/16" open end wrench to tighten
swivel adapter nut.