5. LAMP INSTALLATION

1) Concrete Pool with PVC conduit
BREAK CONDUITS
Junction Box
ABOVE WATERLINE
PVC pipe
TO
TRANSFORMER
SOIL
1.5"/GB50 PVC Pipe
3) Panel Pool / Timber Pool (with EM2836A/E)
BREAK CONDUITS
Junction Box
ABOVE WATERLINE
PVC pipe
1.5"/GB50 PVC Pipe
TO
TRANSFORMER
G1.5A Screwthread EM2836
5 Concrete Pool with Conduit with EM2831A/E+EM2841
)
BREAK CONDUITS
Junction Box
ABOVE WATERLINE
PVC pipe
1.5"/GB50 PVC Pipe
TO
TRANSFORMER
Conduit EM2841
SOIL
G1.5A Screwthread EM2831
Installation Steps:
PVC Pipe
1) PVC pipe: Prepare the correct Front fitting unit (A:
PN10, B: PN16, 1.5" Class 12/15)
P5
LAMP INSTALLATION
WATER LINE
POOL FINISH
15mm MAX
(
)
50mm
10mm MIN
(
)
MINIMUM
CONCRETE THICKNESS
CONCRETE
COVERAGE
WATER LINE
Liner
Rubber ring
Rubber ring
(
)
WATER LINE
(
)
(
)
POOL FINISH
15mm MAX
(
)
120mm
10mm MIN
(
)
MINIMUM
CONCRETE
CONCRETE
THICKNESS
COVERAGE
A
B
2) Vinyl pool / Fiberglass Pool (with EM2836A/E)
BREAK CONDUITS
Junction Box
ABOVE WATERLINE
PVC pipe
TO
TRANSFORMER
G1.5A Screwthread EM2836
4) Concrete Pool (with EM2831A/E)
BREAK CONDUITS
Junction Box
ABOVE WATERLINE
PVC pipe
TO
TRANSFORMER
SOIL
G1.5A Screwthread EM2831
6) Concrete Pool + liner (with EM2831A/E+ EM2841)
BREAK CONDUITS
Junction Box
ABOVE WATERLINE
PVC pipe
1.5"/GB50 PVC Pipe
TO
TRANSFORMER
Conduit EM2841
SOIL
G1.5A Screwthread
Concrete/ Panel/ Timber/ Vinyl pool / Fiberglass Pool
1) Prepare the correct Front fitting unit
WATER LINE
Rubber ring
1.5"/GB50 PVC Pipe
(
)
WATER LINE
(
)
POOL FINISH
15mm MAX
(
)
50mm
10mm MIN
(
)
MINIMUM
CONCRETE
COVERAGE CONCRETE THICKNESS
WATER LINE
Liner
Rubber ring
Rubber ring
(
)
POOL FINISH
15mm MAX
(
)
120mm
10mm MIN
(
)
MINIMUM
CONCRETE THICKNESS
CONCRETE
COVERAGE

Advertisement