Disassembly

Disassembly
Indoor Unit
WARNING: Disconnect the unit from
power supply before making any
checks. Be sure the power switch is set
to "OFF"
1. Open panel front
• Pull the upper part of the front panel.
• Lift up the panel.
• To detach the front panel, remove the two screws
at the lower part.
• Detach the front panel from the body.
• To detach the panel, disconnect the connector at
the upper part.
2. To remove the Control Box.
- Before removing the control box, be sure to
disconnect the wires from PWB.
- Pull the cover control out from the control box
and disconnect other wires.
- Remove securing screws.
- Pull the control box out from the chassis carefully.
40 Room Air Conditioner
Motor Connector
AC/DC Connector
Panel Front
Connector
Step Motro Connector
HVB Connector
Front Panel Connector
Sensor Connector