Detex DSI DS500 Service & Installation Manual

Waist high turnstile

Advertisement

Quick Links

DS500 Waist High Turnstile
Note: Successful turnstile installation depends on reading this manual.
Please keep this service manual after installation. If an installation is done by a construction company
or outside installer, please pass this book along to the end user. This book is required for maintenance,
troubleshooting & repairs.
512-321-4426
INS-DS500-190401
Service & Installation Manual
Designed Security, Inc - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555
sales@dsigo.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSI DS500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Detex DSI DS500

  • Page 1 DS500 Waist High Turnstile Service & Installation Manual Note: Successful turnstile installation depends on reading this manual. Please keep this service manual after installation. If an installation is done by a construction company or outside installer, please pass this book along to the end user. This book is required for maintenance, troubleshooting &...
  • Page 2: Important Electrical Information

    Important Electrical Information Installation of the control head mechanism into the turnstile requires a grounding-type outlet recep- tacle installed inside of the frame or cabinet through the provided conduit access points. To reduce the risk of electric shock, this equipment has a grounding type plug that has a third Additionally, the P24-60W power supply from this appliance must be grounded to the frame of the turnstile.
  • Page 3: Table Of Contents

    Table of Contents Important Electrical Information Model Datasheet Preinstallation Tips Installation Instructions Concrete Anchor Information Mechanical Overview Internal Parts Breakdown Parts List Locking Bar Information Hydraulic Shock & Indexing Electrical Introduction Wiring Diagram Wiring Legend Logic Controller Settings Testing Procedure Limit Switch &...
  • Page 4: Model Datasheet

    The DS500 Series Waist-High DS500 DS500-C | DS500-T Bolt Down | Interior & Exterior Application The DS500 Series is made for years of reliable service like stadiums, convention centers, landmarks and military bases Thousands are currently in use at leading pro-sports venues, attractions worldwide.
  • Page 5 The DS500 Series Waist-High DS500 DS500-C | DS500-T Bolt Down | Interior & Exterior Application Applications: Operation Features 6500 Series Control Head: Input Voltage: 100-240 VAC This series is made for years of reliable service Input Current: 1.3 - .55 A •...
  • Page 6: Preinstallation Tips

    Pre-installation Tips To ensure an easy installation, please review the following tips before trying to install the unit. Lid Removal The top lid on most of our waist high models is held in place on the front side with a lock and two hooks that connect to the cabinet on the rear.
  • Page 7: Installation Instructions

    Waist High Cabinet Installation Instructions Place upright cabinet with front panel removed onto a level surface +/- 1/16”. If the surface is may cause it to work improperly. Mark or punch the oor using the four anchor holes on the oor plate as a template and drill four 3/8”...
  • Page 8: Concrete Anchor Information

    Wedge Type Concrete Anchor Instructions Select a carbide drill bit with a diameter equal to the anchor diameter. Drill hole at least 1/4” deeper than nominal anchor embedment. Clean hole with pressurized air or vacuum to remove any excess dust/debris. Using the washer and nut provided, assemble the anchor, leaving nut one half turn from the end of anchor to protect threads.
  • Page 9: Mechanical Overview

    6500 Series Control Head Mechanical Information All of our turnstiles and ADA gates operate with a mechanism called the 6500 Series Control Head. This sturdy and easy to maintain drive for the turnstile has replaced all previous model control heads. It is adaptable to nearly any existing turnstile and comes with each new turnstile purchase.
  • Page 10: Internal Parts Breakdown

    Designed Security, Inc - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555 512-321-4426 sales@dsigo.com INS-DS500-190401...
  • Page 11: Parts List

    Control Head Castings Locking Bar Assemblies – I2 IB IC ID IE 0373 - Bottom Casting 0382 - Fail Open Assembly XD10 0740 - Logic Controller (XD10) – 0372 - Top Casting 0383 - Fail Lock Assembly Shock Housing Assemblies Hydraulic Shock Absorbers –...
  • Page 12 operating with the 6500 Series Control Head self-center with a spring driven indexing pin and hydraulically shock to the home position to prevent damage or injury. Manual both ways: with an out of service lockout bar which would allow the end user to lock the turnstile with a standard pad lock.
  • Page 13: Locking Bar Information

    6500 Series Control Head Locking Bar Information The 6500 Series Control Head is built to order based on a direction set up sheet sent with cabinet on the left for waist high. “No passage” directions include a fail lock locking bar assembly as well as an unwired solenoid. This adds the appropriate parts to the control head to prevent it from rotating in that direction.
  • Page 14 6500 Series Control Head Locking Bar Information (Continued) Extra components are required to do so. Locking bar assemblies are held together with 1/8” spring pins. Extracting these pins and Replacing an entire locking bar assembly is simple; punch the .5” dowel pin from the pivot point through the head casting (via a small hole in the bottom casting for this purpose), pull out the old locking bar assembly and replace it with the new one.
  • Page 15: Hydraulic Shock & Indexing

    6500 Series Control Head Hydraulic Shock Information The 6500 Series Control Head utilizes a spring loaded index pin for auto-centering the cam Set properly, the shock will allow a turnstile or gate to self-center while rotating smoothly without slamming. use a .75” diameter shock while larger full heights use a 1” diameter shock. Index Pin Hydraulic Shock 3/4”...
  • Page 16: Electrical Introduction

    6500 Series Control Head Electrical Information Each electronic control head comes with a power supply, a programmable logic controller (PLC), limit switches (or optionally, proximity sensors) and solenoids. For safety purposes, it is recommended that you read all literature on the electrical components before attempting to install the control head into a turnstile.
  • Page 17: Wiring Diagram

    6500 Series Control Head w/ XD10 Controller Standard Wiring Diagram Input Voltage: Direction 1 Direction 2 Direction 1 Direction 2 100-240 VAC Access Control Relay Access Control Relay Override Relay Override Relay 1 Phase N.O. N.O. N.O. N.O. 1.1 - .6A Max 50/60 Hz + –...
  • Page 18: Wiring Legend

    6500 Series Control Head w/ XD10 Controller Standard Wiring Legend – I2 IB IC ID IE Direction 1 - Clockwise on full height turnstiles or cabinet on right for waist high turnstiles & ADA gates. Inputs Dir 1 Dir 2 Dir 1 Dir 2 Dir 1...
  • Page 19: Logic Controller Settings

    6500 Series Control Head Limit Switch Information Electronically controlled 6500 Series Control Heads utilize limit switches (or optionally, proximity sensors) in order to detect rotation. Depending on the type of unit (turnstile or ADA gate), the limit switch for a direction may be on the left or the right hand side of the control head. Turnstile Control Head ADA Gate Control Head Limit...
  • Page 20: Testing Procedure

    6500 Series Control Head w/ XD10 Controller Standard Turnstile Settings The XD10 logic controller on the 6500 Series Control Head has a text based menu screen to adjust settings and view statistics of the turnstile. Pressing the A button will cycle to each of the screens available on the device.
  • Page 21: Limit Switch & Limit Switch Cam Information

    6500 Series Control Head w/ XD10 Controller Standard Turnstile Testing The XD10 logic controller on the 6500 Series Control Head can be activated by contact closures between 24VDC+ and the relevant input. New technology allows for simpler on-board testing as well. To diagnose issues with the unit, press A on the keypad to cycle between screens until the testing mode screen appears.
  • Page 22: Maintenance & Cleaning

    Maintenance & Cleaning tained more frequently. Annual Servicing - Secure all nuts & bolts throughout each model. This includes concrete anchors, carriage bolts holding together mainframes, and the bolts holding the control head assembly together. - Remove the index pin assembly from the control head by disconnecting the two extension springs &...
  • Page 23: Troubleshooting

    6500 Series Control Head w/ XD10 Controller Troubleshooting Symptoms Causes Solutions Verify outlet receptacle installed Power supply is not receiving in mainframe / cabinet is input voltage. operating correctly and that the power supply is plugged in. Remove + lead from power supply output.
  • Page 24 6500 Series Control Head w/ XD10 Controller Troubleshooting Symptoms Causes Solutions Access control device output Wire access control to I1 or I2 connected to override inputs. with one-shot timer enabled. This can be avoided by enabling the one-shot timers built into the Access control device output set logic controller program.
  • Page 25 6500 Series Control Head w/ XD10 Controller Troubleshooting Symptoms Causes Solutions Remove locking bar assembly from control head (easiest way on Mechanical bind between locking Unit remains locked after access non-key lock models is to punch bar and cam assembly (typically control is presented until arm is out dowel pin pivot point from from unit being out of plumb or...
  • Page 26: Proper Turnstile Usage

    Proper Turnstile Usage The 6500 Series Control head is easy to use. There are a few things that users should be trained on and informed of. - In the case of an electronic turnstile, approach the unit and present access control credentials. Do not push on the arms of the rotor until after the access control device successfully unlocks the turnstile.
  • Page 27: Warranty

    Warranty Information The DSI Product you have purchased is warranted to be free of defects in material and workmanship when properly installed, used, and maintained according to instructions. DSI will, for a period of one (1) year, three (3) years for Optical Turnstiles, from date of purchase repair or replace any part which, upon our examination, prove to be defective under normal use.

Table of Contents