Table 3-2. Functional Parameters

FUNCTIONAL
SELECTIONS
PARAMETER
SILENT MODE
NO
YES
DEFROST
1.5HRS
INTERVAL TIMER
3HRS
SET FOR
6HRS
12HRS
SET S/S PARAMETERS
(These may be displayed individually (8
parameters) as PERISH and FROZEN, or
combined (4 parameters) with no
designation.)
S (PERISH /
4MINS
TO
FROZEN)
60MINS
MIN RUN
TIME:
(in 1 minute
increments)
S (PERISH /
10MINS
TO
FROZEN)
90MINS
MIN OFF
TIME:
20MINS
(in 1 minute
increments)
S (PERISH /
3.6
°
F (2
FROZEN)
TO
OVERRIDE
18
°
F (10
TEMP:
11
F (6
°
(in 0.5°F or C
increments)
S (PERISH /
OFF
10MINS
FROZEN)
TO
MAX OFF
255MINS
TIME:
(in 1 minute
increments)
62-11039
NO -- Normal engine speed operation.
YES -- Low engine speed operation.
The defrost timer will automatically put the unit into the defrost cycle at
the interval selected if any one compartment DTTS is below 40°F
(4.4°C).
Shorter times are generally used for warm, humid products like pro-
duce.
Longer times can be used for dry and frozen products.
Time and Temperature values that control the Automatic Start--Stop
operation are set in this section.
Configurations, only Perishable Settings are used.
This determines the minimum length of time the unit will run every time
the unit starts in Auto Start--Stop Modes.
This determines the minimum length of time the unit will remain off
whenever the unit cycles off in Auto Start--Stop Modes.
This selects the override temperature for the Auto Start--Stop Off
°
C)
Cycle. During the Minimum Off Time, should the refrigerated compart-
ment temperature drift this far above or below setpoint in the Perish-
°
C)
able Range, or above setpoint in the Frozen Range, the unit will over-
C)
°
ride the Minimum Off Time, and restart.
OFF -- There is no maximum off time.
When a minute value is selected, this is the longest amount of time the
unit will remain off during a (Perishable or Frozen or both) Auto Start--
Stop Off Cycle. When this time expires, the unit will restart and run for
the Minimum Run Time, regardless of any temperature change inside
the refrigerated compartment.