9 INSTALLATION GUIDELINES
9.1 The HY-WDC2E can be mounted on top mast posts, poles, tripods, etc.
Depending on the application. Pole should have three 3 equally spaced
holes for M5 screw 7.5mm lower than top of pole, put cable(waterproof
aerial plug) through pole. HY-WDC2E should be mounted two to three
meters above ground.
Note: The user must have proper stress relief on the cable. Turn the plug and
press it gently into the socket to connect the plug to the HY-WDC2E outlet.
When the plug is connected, turn the outer sleeve clockwise and lock the
plug. With 3 stainless steel screws, the HY-WDC2E can be fixed to the
mounting pipe (the screw has a maximum installed torque of 4Nm).
(refer to picture on the bottom)
Orientation: Use a standard compass to find correct geographic north direction
then align north marker to it, then fix anemometer
.
9.2
You will need to adjust the anemometer so that it is level. Use a bubble