Page 1
OZONE GENERATOR FOR SPAS INSTALLATION & OPERATIONS MANUAL For Models: Platinum MANUFACTURED BY San Luis Obispo, CA 93401 4-0025 Rev. B.- 071105...
Page 2
To validate your warranty, fill in the enclosed warranty registration card and return it to DEL Ozone within ten (10) days of your purchase. Buyer’s acceptance of the product and use thereof constitutes acceptance of these terms.
IMPORTANT SAFETY INSTRUCTIONS Proper installation and safe use of your DEL spa ozonator is your responsibil- ity. Read and follow this Owner’s Manual carefully for important installations, operation and safety information. Basic safety precautions should always be followed, including the following: 1.
TABLE OF CONTENTS Important Safety Instructions............... 1 Table of Contents ................2 How The DEL Spa Ozonator Works ........... 3 Installation Parts .................. 3 Tools and Materials ................3 Unit Assembly..................3 Installation Mounting ..................4 Ozone Supply Tubing Connection ..........4 “Ozone Ready”...
HOW THE DEL SPA OZONATOR WORKS The Spa Eclipse Platinum ozonator that you have just purchased is a high- output ozonator capable of sanitizing spas up to 1200 gallons. When used in conjunction with a small residual of chlorine (.5-1 PPM), the Platinum will simply provide you with the healthiest, clearest and purest water available.
NOTE: If the ozonator is used on an indoor spa, the unit needs the optional Mixing Degas Valve (MDV) or have adequate ventilation. Attach the Platinum Spa Eclipse to a solid surface using screws (included). OZONE SUPPLY TUBING Your ozonator includes 5’...
OZONE SUPPLY TUBING CONNECTION LOCATIONS: OZONE-READY SPAS If your spa is factory equipped with an ozone injection point, follow the manu- facturer’s installation instructions or check with your dealer. After installation, you will need to test the suction at the injection point. Refer to the section titled “DEL Suction Test”...
Page 8
INSTALLATION FOR LOCATIONS “A” & “B”: Turn off the electrical power and drain the spa at least 12 inches below the selected “A” (Figure 2) or “B” (Figure 3) location. The installation instruction for locations “A” & “B” are identical except that location “A” utilizes a vertical air venturi line and location “B”...
PLASTIC HOSE CONNECTOR INSTALLATION: A plastic hose connector installed onto the air venturi line may be used when the spa is not “ozone ready”. If the spa is plumbed with fl exible PVC pipe, an appropriately sized PVC tee fi tting, with the center having 1/2” female threads (not included) must be installed (see Figure 3).
INSTALLATION FOR LOCATION “C”: Turn off the electrical power and drain the spa at least 12 inches below the air venturi line which provides the best suction and is connected to the lowest jet. Cut the PVC flex tube approximately 3” to 4” from the air control valve. Install an appropriately sized PVC reducer fitting (not included), with 1/2”...
Page 11
Turn off the electrical power and completely drain the spa. The DEL RIGID INJECTOR MANIFOLD must be installed in the spa’s return line after all other equipment (pump, filter and heater). It should be installed as close to the spa as possible.
The Platinum Spa Eclipse requires the addition of a minimum 8 AWG grounding wire, to comply with local requirements (this wire must be connected from the open ground lug of the power supply cartridge to a grounding point).
FAILED DEL SUCTION TEST Very little or no suction may be caused by the list of possible problems below. Review the list then test for suction again. 1. Dirty filter: Clean the filter and test again 2. Clogged jets: Clean and test again 3.
It should be hooked up so that it operates automatically with the spa system. If it does not, refer back to the electrical section. MAINTENANCE There are no end-user servicable parts on the Platinum ozonator except for a fuse. See the Trouble Shooting Section for help replacing the fuse.
TROUBLE SHOOTING SYMPTOM: Cloudy water condition even though the unit appears to be operating properly. PROBABLE CAUSE CORRECTIVE ACTION 1. Unit and pump not operating 1A.Increase operating time (min. 6 hours long enough is recommended) 2. Total alkalinity not correct 2A.
Page 19
DEL Ozone WARRANTY REGISTRATION CARD Product Serial Date: Fill out completely and return to DEL Ozone within ten (10) days of purchase. Customer Info: Name ___________________________ Phone ( ) ______________ Address ___________________________________________________ City ____________________________ State ________ Zip __________ Dealer Info:...
Page 20
DO NOT FORGET TO CUT OUT AND MAIL THIS CARD FOR INSTANT WARRANTY COVERAGE! DEL Ozone ATTN: Warranty Dept. 3428 Bullock Lane San Luis Obispo, CA 93401-9787...