Table of Contents General Information Case Section Installation Case Refrigeration Spec Sheet Electrical Wiring Diagram Index Wiring Diagram User Information Maintenance Troubleshooting Warranty...
Shortages: Check your shipment for any possible shortages of material. If a shortage should exist and is found to be the responsibility of Hussmann Chino, notify Hussmann Chino. If such a shortage involves the carrier, notify the carrier immediately, and request an inspection. Hussmann Chino will acknowledge shortages within ten days from receipt of ...
Case Sections (457) (1644) (736) 1/4 (1276) (1625) MPC-ET (1778) Elec Refrig Drain Panels customer side (29) (1828) (2438) (3657)
Page 5
Unloading Receiving Case Warning Labels Loose Upon receiving your new Hussmann Case all equipment Items should be thoroughly examined for shipping damage be‐ fore and during unloading. This equipment has been care‐ fully inspected at our factory. Any claim for loss or damage must be made to the carrier.
Installation Location MPC‐ET Lifting and Transport Instructions The Mobile Produce Case display has been designed for use only in air conditioned stores where temperature and humidity are maintained either 75°F ambient and 55% RH. NOTE: The MPC‐ET CANNOT be lifted with a forklift and should only use dollies for transportation.
Page 7
Installation Cont’d Level Case Position the case at the highest point. Set a long magnetized level (4ft [1220 mm] or more) on either underneath the deck or on top of the case. Ensure to level case from front to back and side to side. Level (4 ft[1220mm]) Level...
Page 9
Installation Cont’d Setting and Joining Snapping Chalk Lines The sectional construction of these models enable them Prepare permanent positioning by marking floors with to be joined in line to give the effect of one continuous Chalk snap lines where cases are to be located. Chalk lines are to run along the base or legs of cases.
Page 10
Installation (cont’d) Setting STEP 1. Using case blueprints, measure off and mark on STEP 2. Set first case over the highest part of the floor and the floor the exact dimensions of where the cases will sit. adjust legs so that case is level. Snap chalk line for front and back positions of base rail or ...
Page 11
Installation (cont’d) STEP 6. To compress butyl at joint, use two Jurgenson STEP 4. Apply liberal bead of case joint sealant (Silicone) wood clamps. Make sure case is level from front to back to first case. Sealant area is shown in illustration. Apply and side to side on inside bulkheads at joint.
Page 12
Installation (cont’d) Front Body Panel Access Located in the lower front body panel is an easily acces‐ sible access panel which can be detached by removing the fastened sccrews which hold the panel in place. Removing this access panel gains access to some of the merchandis‐ ers electrical components as well as other components to ...
Refrigeration Refrigerant Refrigerant piping The correct type of refrigerant will be stamped on each The refrigerant line connections are at the right hand merchandiser’s serial plate. The case refrigeration piping end of the case (as viewed from the front) beneath the is pressurized with a nitrogen holding charge, leak tested display pans.
Refer to label affixed to case to determine the actual This includes (but not limited to) Fans, Heaters configuration as checked in the “TYPE INSTALLED” Thermostats, and Lights. boxes. Wiring Diagram Index MPC-ET-6-R W/KILL SWITCH 3089663 2/28/2019 MPC-ET-8-R W/KILL SWITCH 3089664 2/28/2019...
User Information Start Up Load Limit See the merchandisers Data Sheet Set for refrigerant Each Merchandiser has a load limit. Shelf life of per‐ settings and defrost requirements. Bring merchandisers ishables will shorten if load limit is violated. down to the operating temperatures listed on the Data Sheet.
Maintenance Case Cleaning Long life and satisfactory performance of any equipment Rinse and wipe dry immediately after cleaning. Never use are dependent upon the care it receives. To insure long hydrochloric acid (muriatic acid) on stainless steel. life, proper sanitation and minimum maintenance costs, the merchandiser should be thoroughly cleaned, all debris ...
Page 25
Maintenance Cont’d Do not use steam or high pressure water hoses to wash the interior. These will destroy the merchandis‐ ers’ sealing causing leaks and poor performance. • Avoid direct contact between fan motors and cleaning or rinse water. • Rinse with hot water, but DO NOT flood. Never intro‐ duce water faster than the waste outlet can drain.
Troubleshooting Problem Possible Cause Possible Solution Case temperature is Ambient conditions may Check case position in store. Is the case located near an too warm. be affecting the case open door, window, electric fan or air conditioning vent that operation. may cause air currents? Case must be located minimum 15 Ft away from doors or windows.
Page 27
Troubleshooting Cont’d Problem Possible Cause Possible Solution Water has pooled Case drain is clogged. Clear drain. under case. PVC drains under case Repair as needed. may have a leak. Case tub has unsealed Seal as needed. opening. If the case is in a line- Install case to case joint and seal as needed.
Page 28
August 31, 2018 This warning does not mean that Hussmann products will cause cancer or reproductive harm, or is in violation of any product-safety standards or requirements. As clarified by the California State government, Proposition 65 can be considered more of a ‘right to know’...
To obtain warranty information or other support, contact your Hussmann representative. Please include the model and serial number of the product. Hussmann Warranty / Technical Assistance (800) 592-2060 Hussmann Corporation, Corporate Headquarters: Bridgeton, Missouri 63044 2014...
Need help?
Do you have a question about the MPC-ET and is the answer not in the manual?
Questions and answers